OSHA Inspection: VIESEL FUEL LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of VIESEL FUEL LLC in 3041 SE DOMINICA TERRACE, STUART, FL 34997 (NAICS 311225). OSHA activity number 338445638.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Viesel Fuel LLC — free Get an email when a new federal OSHA severe-injury report for Viesel Fuel LLC is published. One employer, no account, unsubscribe in one click.
Establishment
VIESEL FUEL LLC
Site address
3041 SE DOMINICA TERRACE
City
STUART
State
FL
ZIP
34997
Mailing
3041 SE DOMINICA TERRACE, STUART, FL 34997
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311225
Employees
15
Ownership type
A

6 citations on file for this inspection.

1910.120 Q01

Serious Gravity 10 1 instance 4 exposed
Issued
Apr 18, 2013
Abate by
May 14, 2013
Penalty
Initial $2,800 · Current $2,100 Reduced
29 CFR 1910.120(q)(1): The employer did not develop and implement an emergency response plan to handle anticipated emergencies prior to commencement of emergency response operations:     On or about 01-23-13, the employer had not developed an emergency response plan to respond to releases of hazardous materials.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $2800

1910.147 C01

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 18, 2013
Abate by
May 14, 2013
Penalty
Initial $1,600 · Current $1,100 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:    On or about 01-23-13, the employer had not established a program to control the repairs and maintenance of the steam heating system.
Recent events (2)
  • — I (S) $1100
  • — Z (S) $1600

1910.243 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 18, 2013
Abate by
May 14, 2013
Penalty
Initial $1,600 · Current $1,100 Reduced
29 CFR 1910.243(c)(1): Abrasive wheel(s) were used on portable grinder(s) which were not provided with safety guard(s) meeting the requirements specified in 29 CFR 1910.243(c)(1) through (c)(4):     On or about 01-23-13, a Bosch angle grinder which did not have a guard was used by an employee to grind metal parts.
Recent events (2)
  • — I (S) $1100
  • — Z (S) $1600

1910.253 B04 III

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 18, 2013
Abate by
Apr 30, 2013
Penalty
Initial $2,400 · Current $1,700 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one half hour:    On or about 01-23-13, in the Maintenance area, oxygen cylinders were stored next to acetylene cylinders and within five feet of oil and greases.
Recent events (2)
  • — I (S) $1700
  • — Z (S) $2400

1910.333 C10

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 18, 2013
Abate by
May 14, 2013
Penalty
Initial $2,000 · Current $1,500 Reduced
29 CFR 1910.333(c)(10): A person not qualified defeated an electrical safety interlock while working on the equipment:    On or about 01-23-13, at the electrical panel in front of the centrifuge pump, an employee had bypassed the safety interlock to open the electrical panel so he could access the RPM gauge.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2000

1910.178 L06

Other-than-serious 1 instance 2 exposed
Issued
Apr 18, 2013
Abate by
May 14, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l):  On or about 01-23-13, the employer had not certified any employee to operate a forklift.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0