EDWARDSVILLE, IL —
OSHA Inspection: MADISON COUNTY ROOFING AND HOME IMPROVEMENT INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MADISON COUNTY ROOFING AND HOME IMPROVEMENT INC. in 3312 GARVEY LN., EDWARDSVILLE, IL 62025 (NAICS 236115). OSHA activity number 338507866.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MADISON COUNTY ROOFING AND HOME IMPROVEMENT INC.
- Site address
- 3312 GARVEY LN.
- City
- EDWARDSVILLE
- State
- IL
- ZIP
- 62025
- Mailing
- #5 HARMONY LANE, COLLINSVILLE, IL 62234
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236115
- Employees
- 8
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.20 B02
- Issued
- Feb 15, 2013
- Abate by
- Mar 14, 2013
- Penalty
- Initial $2,200 · Current $0 Reduced
General-duty citation text
29 CFR 1926.20(b)(2): Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers. Employees working from a 6 in 12 pitch roof were exposed to falls of approximately 11 feet to a lower level. The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person.
Recent events (2)
- — I (O) $0
- — Z (S) $2200
1926.501 B13
- Issued
- Feb 15, 2013
- Penalty
- Initial $3,080 · Current $2,156 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems. Employees working from a 6 in 12 pitch roof were exposed to falls of approximately 10 feet to a lower level. Employees were not protected from falling by guardrail systems, safety net systems, or personal fall arrest or any other approved means.
Recent events (2)
- — I (S) $2156
- — Z (S) $3080
More inspections at Madison County Roofing and Home Improvement INC.
View Madison County Roofing and Home Improvement INC.'s full OSHA safety record →