KANSAS CITY, MO —
OSHA Inspection: DE LAVAL, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DE LAVAL, INC. in 11100 NORTH CONGRESS AVENUE, KANSAS CITY, MO 64153 (NAICS 333111). OSHA activity number 338541832.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DE LAVAL, INC.
- Site address
- 11100 NORTH CONGRESS AVENUE
- City
- KANSAS CITY
- State
- MO
- ZIP
- 64153
- Mailing
- 11100 NORTH CONGRESS AVENUE, KANSAS CITY, MO 64153
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333111
- Employees
- 139
- Ownership type
- A
Citations
14 citations on file for this inspection.
1910.22 D01
- Issued
- Feb 14, 2013
- Penalty
- Initial $2,550 · Current $1,530 Reduced
General-duty citation text
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate. (a) Warehouse: The shelving did not have a load rating where there was a walkway under the shelving units.
Recent events (2)
- — I (S) $1530
- — Z (S) $2550
1910.147 C04 II C
- Issued
- Feb 14, 2013
- Penalty
- Initial $4,250 · Current $2,550 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(C): The energy control procedure did not clearly and specifically outline the steps for placement, removal and transfer of lockout devices or tagout devices and the responsibility for them. (a) Filter Area: There are no machine specific lockout tagout procedures for machines, such as, but not limited to, Machine # 1 in the Filter Area.
Recent events (2)
- — I (S) $2550
- — Z (S) $4250
1910.212 A01
- Issued
- Feb 14, 2013
- Abate by
- Mar 22, 2013
- Penalty
- Initial $3,400 · Current $2,040 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) UCon Area: Employees were exposed to the drill press which did not have an adjustable guard to cover the unused portion of the bit and chuck above the material being worked. (b) Assembly Area: The Sears/Craftsman Industrial Rated Drill Press did not have an adjustable guard to cover the unused portion of the bit and chuck above the material being worked. (c) Filter Area: Machine # 1 did not have a guard for the fan.
Recent events (2)
- — I (S) $2040
- — Z (S) $3400
1910.215 A04
- Issued
- Feb 14, 2013
- Penalty
- Initial $3,400 · Current $2,040 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: (a) Assembly Area: The blue bench grinder on the cart did not have a work rest.
Recent events (2)
- — I (S) $2040
- — Z (S) $3400
1910.215 B09
- Issued
- Feb 14, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: (a) Assembly Area: The blue bench grinder had the tongue guard adjusted at greater than one fourth inch.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.219 D01
- Issued
- Feb 14, 2013
- Abate by
- Mar 22, 2013
- Penalty
- Initial $3,400 · Current $2,040 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): (a) Assembly Area: The Benchmaster 4 ton press did not have the pulleys guarded within seven feet of the floor. The belt and pulleys create an ingoing nippoint which was not guarded.
Recent events (2)
- — I (S) $2040
- — Z (S) $3400
1910.219 E01 I
- Issued
- Feb 14, 2013
- Abate by
- Mar 22, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs seven feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt: (a) Assembly Area: The Benchmaster 4 ton press the horizontal belts were not guarded within seven feet from the ground.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.242 B
- Issued
- Feb 14, 2013
- Abate by
- Mar 22, 2013
- Penalty
- Initial $2,550 · Current $1,530 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: (a) Filter Assembly: The two air nozzles used for cleaning were not reduced to less than 30 p.s.i.
Recent events (2)
- — I (S) $1530
- — Z (S) $2550
1910.303 B02
- Issued
- Feb 14, 2013
- Abate by
- Mar 22, 2013
- Penalty
- Initial $2,550 · Current $1,530 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: (a) Assembly: The metal on/off switch with knockouts was used for the Bell Press. A metal on/off switch box with knockouts is listed or labelled to be used with rigid conduit and attached to a wall, or machine.
Recent events (2)
- — I (S) $1530
- — Z (S) $2550
1910.303 F02
- Issued
- Feb 14, 2013
- Abate by
- Mar 22, 2013
- Penalty
- Initial $2,550 · Current $1,530 Reduced
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: (a) Assembly Battery Charging Station: The breakers for the Cutler-Hammer electrical panel # P8 were not labelled at the panel box.
Recent events (2)
- — I (S) $1530
- — Z (S) $2550
1910.304 G05
- Issued
- Feb 14, 2013
- Penalty
- Initial $2,550 · Current $1,530 Reduced
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: (a) Warehouse Breakroom: The duplex outlet that the Emerson microwave was plugged into was not grounded.
Recent events (2)
- — I (S) $1530
- — Z (S) $2550
1910.305 B01 II
- Issued
- Feb 14, 2013
- Penalty
- Initial $2,550 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: (a) Assembly Area: A knockout was open for the 220 volt outlet to the left of the lathe. (b) Assembly Tag Area: A knockout was open for the four-plex outlet by the work bench area.
Recent events (2)
- — I (S) $0
- — Z (S) $2550
1910.305 G01 IV D
- Issued
- Feb 14, 2013
- Penalty
- Initial $2,550 · Current $1,530 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(D): Flexible cords were attached to building surfaces: (a) Assembly Tag Area: The power strip or relocatable power tap was attached to the wooden wall above the work bench.
Recent events (2)
- — I (S) $1530
- — Z (S) $2550
1910.305 G02 III
- Issued
- Feb 14, 2013
- Penalty
- Initial $3,400 · Current $2,040 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: (a) Maintenance Area: There was not adequate strain relief to the Thermal Dynamics welder. At the plug-in there was not adequate strain relief as the outer insulation had pulled back exposing interior wiring where the plug-in joined the cord. (b) Maintenance Area: There was not adequate strain relief for the Thermal Dynamics welder at the rear of the welder where the power cord attached to the welder as the outer insulation had pulled back exposing interior wiring.
Recent events (2)
- — I (S) $2040
- — Z (S) $3400
More inspections at DE Laval, INC.
View DE Laval, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 333111)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338541832.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.