TAMPA, FL —
OSHA Inspection: M K. CONSTRUCTION GROUP INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of M K. CONSTRUCTION GROUP INC. in 5833 S. 5TH ST., TAMPA, FL 33611 (NAICS 238140). OSHA activity number 338544034.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- M K. CONSTRUCTION GROUP INC.
- Site address
- 5833 S. 5TH ST.
- City
- TAMPA
- State
- FL
- ZIP
- 33611
- Mailing
- 5379 LYONS RD UNIT 225, COCONUTCREEK, FL 33093
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 10
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.451 C02
- Issued
- Feb 21, 2013
- Penalty
- Initial $2,520 · Current $2,520
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation: Instance 1) At the jobsite, east side of residence, the base of the tubular welded frame scaffolding was not adequately supported, in that, base plates were not installed on the scaffold legs to provide a firm foundation. Instance 2) At the jobsite, north side of residence, the base of the tubular welded frame scaffolding was not adequately supported, in that, mud sills were not installed on the scaffold legs to provide a firm foundation.
Recent events (1)
- — Z (S) $2520
1926.451 E01
- Issued
- Feb 21, 2013
- Penalty
- Initial $2,520 · Current $2,520
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. Instance 1) At the jobsite, east side of residence, an employee was exposed to fall hazards up to 19'2" while climbing up the end section of the through style tubular welded frame scaffolding, in that, an adequate means of access and egress was not provided. Instance 2) At the jobsite, north side of residence, employees were exposed to fall hazards up to 12'8" while climbing up the end section of the through style tubular welded frame scaffolding, in that, an adequate means of access and egress was not provided.
Recent events (1)
- — Z (S) $2520
1926.451 G01
- Issued
- Feb 21, 2013
- Penalty
- Initial $2,520 · Current $2,520
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: Instance 1) At the jobsite, east side of residence, an employee in the process of plastering was exposed to a 19'2" fall hazard in that, guard rails were not installed on the top work platform on tubular welded frame scaffolding, 3 levels high. Instance 2) At the jobsite, north side of residence, employees in the process of plastering were exposed to a 12'8" fall hazard in that, guard rails were not installed on the top work platform on tubular welded frame scaffolding, 2 levels high.
Recent events (1)
- — Z (S) $2520
1926.501 B01
- Issued
- Feb 21, 2013
- Penalty
- Initial $2,520 · Current $2,520
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. a) At the jobsite, east side of the building, an employee in the process of plastering work while standing on a steep roof, 6 in 12 pitch, was exposed to a 9'4" fall hazard, in that, fall protection equipment was not installed or utilized. Observed on or about 1/29/13.
Recent events (1)
- — Z (S) $2520
More inspections at M K. Construction Group INC.
View M K. Construction Group INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338544034.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.