LENNOX, SD —
OSHA Inspection: KOYKER MANUFACTURING
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of KOYKER MANUFACTURING in 200 NORTH CLEVELAND AVENUE, LENNOX, SD 57039 (NAICS 333111). OSHA activity number 338593841.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- KOYKER MANUFACTURING
- Site address
- 200 NORTH CLEVELAND AVENUE
- City
- LENNOX
- State
- SD
- ZIP
- 57039
- Mailing
- P.O. BOX 1265, SIOUX FALLS, SD 57101
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333111
- Employees
- 55
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.23 E01
- Issued
- Jul 12, 2013
- Abate by
- Jul 30, 2013
- Penalty
- Initial $2,100 · Current $1,470 Reduced
General-duty citation text
29 CFR 1910.23(e)(1): The employer did not provide a standard railing consisting of top rail, intermediate rail, and posts, and shall have a vertical height of 42 inches nominal from upper surface of top rail to floor, platform, runway, or ramp level: (a) On or about January 30, 2013, and at times prior to that date, for employees exposed to an approximate 10-foot fall hazard while accessing the receiving office platform on the mezzanine where no midrail was provided at 200 North Cleveland Avenue, Lennox, South Dakota.
Recent events (2)
- — I (S) $1470
- — Z (S) $2100
1910.212 A01
- Issued
- Jul 12, 2013
- Abate by
- Jul 30, 2013
- Penalty
- Initial $4,900 · Current $3,430 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point-of-operation, ingoing nip points, rotating parts, and/or flying chips and sparks: (a) On or about January 30, 2013, and at times prior to that date, for employees exposed to struck-by hazards from the movement of the Burney plasma cutting structure during the manufacturing fabrication process at 200 North Cleveland Avenue, Lennox, South Dakota.
Recent events (2)
- — I (S) $3430
- — Z (S) $4900
1910.219 C02 I
- Issued
- Jul 12, 2013
- Abate by
- Jul 30, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(c)(2)(i): All exposed parts of horizontal shafting seven (7) feet or less from floor or working platform were not protected by a stationary casing enclosing the shafting completely or by a trough enclosing sides and top or sides and bottom of shafting as location requires: (a) On or about January 30, 2013, and at times prior to that date, for employees exposed to caught-in hazards while accessing the backside of the PS07SHEAR metal shear to retrieve parts during the manufacturing fabrication process at 200 North Cleveland Avenue, Lennox, South Dakota.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 G01
- Issued
- Jul 12, 2013
- Abate by
- Jul 30, 2013
- Penalty
- Initial $2,100 · Current $1,470 Reduced
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space about electric equipment was not provided and maintained to permit ready and safe operation and maintenance of such equipment: (a) On or about January 30, 2013, and at times prior to that date, for employees exposed to electrical shock hazards while accessing the four electrical disconnect panels adjacent to the Burney plasma table with nitrogen and liquid oxygen cylinders blocking access at 200 North Cleveland Avenue, Lennox, South Dakota.
Recent events (2)
- — I (S) $1470
- — Z (S) $2100
1910.305 G01 IV A
- Issued
- Jul 12, 2013
- Abate by
- Jul 30, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: (a) On or about January 30, 2013, and at times prior to that date, for employees exposed to potential electrical hazards where an extension cord was used as a permanent electrical source for a floor-mounted drill press in the fabrication area at 200 North Cleveland Avenue, Lennox, South Dakota.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.252 B02 III
- Issued
- Jul 12, 2013
- Abate by
- Jul 30, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields: (a) On or about January 30, 2013, and at times prior to that date, for welders and other employees exposed to potential welding flash hazards in the welding area at 200 North Cleveland Avenue, Lennox, South Dakota.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Koyker Manufacturing
View Koyker Manufacturing's full OSHA safety record →
More inspections in this industry (NAICS 333111)
More inspections in SD
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338593841.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.