CHICAGO, IL —
OSHA Inspection: MAGENTA, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MAGENTA, LLC in 3800 N. MILWAUKEE, CHICAGO, IL 60641 (NAICS 326199). OSHA activity number 338595242.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MAGENTA, LLC
- Site address
- 3800 N. MILWAUKEE
- City
- CHICAGO
- State
- IL
- ZIP
- 60641
- Mailing
- 3800 N. MILWAUKEE, CHICAGO, IL 60641
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 130
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.147 C04 I
- Issued
- Feb 14, 2013
- Abate by
- May 18, 2013
- Penalty
- Initial $4,500 · Current $2,250 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i):The employer did not ensure that procedures were utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) Molding Rooms- Energy control procedures were not utilized for the control of potentially hazardous energy during maintenance of the injection molding machines.
Recent events (2)
- — I (S) $2250
- — Z (S) $4500
1910.147 C07 I
- Issued
- Feb 14, 2013
- Abate by
- May 18, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees: (a) Molding Rooms - The employer did not provide training for the employees performing maintenance of injection molding machines to ensure that the purpose and function of the energy control program is understood.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C06 I
- Issued
- Feb 14, 2013
- Abate by
- May 18, 2013
- Penalty
- Initial $4,500 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed: (a) Facility Wide - An annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were being followed was not being completed and certified.
Recent events (2)
- — I (S) $0
- — Z (S) $4500
1910.178 A04
- Issued
- Feb 14, 2013
- Abate by
- Mar 13, 2013
- Penalty
- Initial $3,600 · Current $1,800 Reduced
General-duty citation text
29 CFR 1910.178(a)(4): Modifications and additions which affect capacity and safe operation of a powered industrial truck were performed by the employer without the manufacturer's prior written approval: (a) Molding Room/Clean Room- A boom attachment ( serial number B2031) was added to the Yale fork lift truck (serial number N444008) by the employer without the manufacturer's approval.
Recent events (2)
- — I (S) $1800
- — Z (S) $3600
1910.178 A05
- Issued
- Feb 14, 2013
- Abate by
- Mar 13, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(a)(5): The powered industrial truck was equipped with front-end attachments other than factory installed attachments, however the employer did not request that the truck be marked to identify the attachments and show the approximate weight of the truck and attachment combination at maximum elevation with load laterally centered: (a) Molding Room/ Clean Room - The Yale fork lift truck (serial number N444008) with the boom attachment ( serial number B2031) was not marked to identify the attachments and show the approximate weight of the truck and attachment combination at maximum elevation with load laterally centered.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 L04 III
- Issued
- Feb 14, 2013
- Abate by
- Mar 13, 2013
- Penalty
- Initial $3,600 · Current $1,800 Reduced
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: a) Facility wide - All powered industrial truck operators were not evaluated on the operation of the powered industrial trucks at least once every three years.
Recent events (2)
- — I (S) $1800
- — Z (S) $3600
1910.212 A01
- Issued
- Feb 14, 2013
- Abate by
- Mar 13, 2013
- Penalty
- Initial $4,500 · Current $2,250 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, rotating parts and flying chips : (a) Tool Room - One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area of the Clausing - Colchester 13" lathe from hazards such created by the rotating chuck. (b) Maintenance Shop - One or more methods of machine guarding was not provided to protect the operator and other employees in the maintenance shop area from the unused portion of the band saw blade on the Roll-In All Purpose Band Saw.
Recent events (2)
- — I (S) $2250
- — Z (S) $4500
1910.303 G01 II
- Issued
- Feb 14, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: (a) Molding Room/Clean Room - The required working space about a 240 Volt electrical cabinet was used for storage of a storage rack.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Magenta, LLC
View Magenta, LLC's full OSHA safety record →
More inspections in this industry (NAICS 326199)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338595242.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.