Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PACIFIC ISLANDS CLUB GUAM

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PACIFIC ISLANDS CLUB GUAM in 210 PALE SAN VITORES ROAD ED SANDOVAL DIRECTOR OF ENGINEERING, TAMUNING, GU 96913 (NAICS 721110). OSHA activity number 338770472.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Pacific Islands Club Guam — free Get an email when a new federal OSHA severe-injury report for Pacific Islands Club Guam is published. One employer, no account, unsubscribe in one click.
Site address
210 PALE SAN VITORES ROAD ED SANDOVAL DIRECTOR OF ENGINEERING
City
TAMUNING
State
GU
ZIP
96913
Mailing
210 PALE SAN VITORES ROAD, TAMUNING, GU 96913
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
721110
Employees
555
Ownership type
A

6 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 1 instance 5 exposed
Issued
Mar 27, 2013
Penalty
Initial $3,740 · Current $3,000 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by rotating parts:   Kitchen: On February 11, 2013, and at times prior thereto, there was no guard for the rotating portion of the Alcoh Mixer.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $3740

1910.219 D01

Other-than-serious 1 instance 5 exposed
Issued
Mar 27, 2013
Penalty
Initial $3,740 · Current $0 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):  Main Mechanical Room, GenSet#2: On February 11, 2013, and at times prior thereto, a belt and pulley drive driving the altenator was not properly guarded.
Recent events (2)
  • — I (O) $0
  • — Z (S) $3740

1910.219 E01 I

Other-than-serious 1 instance 5 exposed
Issued
Mar 27, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(1)(i):  Horizontal belts which had both runs 42 inches or less from the floor level were not fully enclosed by guards conforming to requirements specified in 29 CFR 1910.219(m) and (o):  Main Mechanical Room, GenSet#2: On February 11, 2013, and at times prior thereto, a belt and pulley drive driving the altenator was not properly guarded.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.303 B02

Serious Gravity 1 1 instance 2 exposed
Issued
Mar 27, 2013
Penalty
Initial $2,806 · Current $2,000 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  Bakery: On February 11, 2013, and at times prior thereto, a relocatable power tap was used to permanently energize a sauce heater.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $2806

1910.305 B01 II

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 27, 2013
Penalty
Initial $3,740 · Current $3,500 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:    Old Pump Room: On February 11, 2013, and at times prior thereto, a 125 amp electrical panel which energized pool area lighting had a dozen of breaker space openings.
Recent events (2)
  • — I (S) $3500
  • — Z (S) $3740

1910.151 C

Repeat Gravity 5 1 instance 5 exposed
Issued
Mar 27, 2013
Penalty
Initial $22,000 · Current $6,500 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:   Main Machanical Room: On February 11, 2013, and at times prior thereto, emergency drenching facilities were not provided for employees who worked with and around corrosive water treatment chemicals.    Pacific Islands Club Guam was previously cited for a violation of this occupational safety and health standard 29 CFR 1910.151(c)which was contained in OSHA Inspection Number 315175323, Citation Number 02, Item Number 002, issued on 07/08/2011, with respect to a workplace located at 210 Pale San Vitores Road, Tumon Bay, Guam, which became final order on 08/05/2011.
Recent events (2)
  • — I (R) $6500
  • — Z (R) $22000

View Pacific Islands Club Guam's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338770472.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.