Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SERRANO CONSTRUCTION AND DEVELOPMENT, CORP.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SERRANO CONSTRUCTION AND DEVELOPMENT, CORP. in NAVAL BASE GUAM BUILDING 3179, SANTA RITA, GU 96915 (NAICS 236220). OSHA activity number 338819642.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Serrano Construction and Development, Corp. — free Get an email when a new federal OSHA severe-injury report for Serrano Construction and Development, Corp. is published. One employer, no account, unsubscribe in one click.
Site address
NAVAL BASE GUAM BUILDING 3179
City
SANTA RITA
State
GU
ZIP
96915
Mailing
P.O. BOX 9467, DEDEDO, GU 96929
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
28
Ownership type
A

4 citations on file for this inspection.

1926.404 F06

Serious Gravity 1 1 instance 1 exposed
Issued
Mar 6, 2013
Abate by
Mar 12, 2013
Penalty
Initial $1,890 · Current $1,300 Reduced
29 CFR 1926.404(f)(6):     Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous.    (a)  At the project on or about February 13, 2013, and at times prior thereto, the path to ground from 110 VAC receptacle was not permanent and continuous.  The receptacle was used to supply power to the 110 VAC Makita HM 1201, demolition hammer, used to chip concrete around the door jamb.
Recent events (2)
  • — I (S) $1300
  • — Z (S) $1890

1926.405 G02 IV

Serious Gravity 1 1 instance 1 exposed
Issued
Mar 6, 2013
Abate by
Mar 12, 2013
Penalty
Initial $1,890 · Current $1,300 Reduced
29 CFR 1926.405(g)(2)(iv):     Strain relief. Flexible cords shall be connected to devices and fittings so that strain relief is provided which will prevent pull from being directly transmitted to joints or terminal screws.    (a)  At the project on or about February 13, 2013, and at times prior thereto, the outer insulation of the 50 foot extension cord was not secured to the plug.  The cord was used to supply power to a 110 VAC Makita HM 1201, Demolition Hammer, used to chip concrete around the door jamb.
Recent events (2)
  • — I (S) $1300
  • — Z (S) $1890

1926.451 E01

Serious Gravity 1 1 instance 1 exposed
Issued
Mar 6, 2013
Penalty
Initial $1,607 · Current $1,170 Reduced
29 CFR 1926.451(e)(1):     When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.    (a)  At the front of the project site (entry door) on or about February 13, 2013, there was no portable ladders, hook-on ladders, attachable ladders, to safely access the working platform of the scaffold.  An employee was observed climbing the end frame of the scaffold to access the working platform.
Recent events (2)
  • — I (S) $1170
  • — Z (S) $1607

1926.451 C02

Other-than-serious 1 instance 1 exposed
Issued
Mar 6, 2013
Abate by
Mar 18, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.451(c)(2):     Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.    (a) At the front of the project site on or about February 13, 2013, the supported scaffold did not bear base plates on each end of the two end frames.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Serrano Construction and Development, Corp.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338819642.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.