Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: LIBERATOR FISHERIES, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of LIBERATOR FISHERIES, LLC in F/V U.S. LIBERATOR, DUTCH HARBOR, AK 99692 (NAICS 311712). OSHA activity number 338875644.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Liberator Fisheries, LLC — free Get an email when a new federal OSHA severe-injury report for Liberator Fisheries, LLC is published. One employer, no account, unsubscribe in one click.
Site address
F/V U.S. LIBERATOR
City
DUTCH HARBOR
State
AK
ZIP
99692
Mailing
5470 SHILSHOLE AVENUE N.W. SUITE 300, SEATTLE, WA 98107
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311712
Employees
20
Ownership type
A

3 citations on file for this inspection.

1915.89 C01

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 12, 2013
Abate by
Apr 12, 2013
Penalty
Initial $1,836 · Current $1,285 Reduced
29 CFR 1915.89(c)(1):     The employer did not ensure that, before any authorized employee performs servicing when energization or startup, or the release of hazardous energy, may occur, all energy sources are identified and isolated, and the machinery, equipment, or system was rendered inoperative.    Coastal dock, F/V U.S. Liberator, Factory:  On or about 7 February 2013 and times prior thereto, a Tokai Header, Model PHC-550, machine number 159, 208V, 3PH; maintenance was being performed on the unit and it was not locked or tagged out.  This condition exposed employees to a caught-in and amputation hazard.
Recent events (2)
  • — I (S) $1285.2
  • — Z (S) $1836

1915.89 C07 IV

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 12, 2013
Abate by
Apr 12, 2013
Penalty
Initial $0 · Current $0
29 CFR 1915.89(c)(7)(iv):    The employer did not ensure the lockout/tags-plus coordinator maintained and administered a continuous log of each lockout and tags-plus system.    Coastal Dock, F/V U.S. Liberator, Factory; on or about 7 February 2013 and times prior thereto, a Tokai Header, Model PHC-550, machine number 159  208V, 3PH; maintenance was being performed on the unit and it was not locked or tagged out. The lockout/tags plus coordinator did not maintain a continuous log of the lock/out tags-plus system. This condition exposed employees to a caught-in hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1915.89 D01

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Mar 12, 2013
Abate by
Apr 12, 2013
Penalty
Initial $0 · Current $0
29 CFR 1915.89(d)(1):     The employers did not include a clear and specific outline of the scope and purpose for each lockout/tags-plus procedure.    Coastal Dock, F/V U.S. Liberator, Factory area; on or about 7 February 2013 and times prior thereto, a Tokai Header, Model PHC-550, 208V, 3PH electrical, maintenance was being performed on the unit and it was not locked or tagged out. No specific written procedures were available to prevent energization or release of hazardous energy.This condition exposed employees to a caught-in hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Liberator Fisheries, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338875644.