PHILADELPHIA, PA —
OSHA Inspection: FASTRACK CONSTRUCTION, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of FASTRACK CONSTRUCTION, INC. in 300 HUNTING PARK AVE, PHILADELPHIA, PA 19147 (NAICS 236220). OSHA activity number 338880032.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FASTRACK CONSTRUCTION, INC.
- Site address
- 300 HUNTING PARK AVE
- City
- PHILADELPHIA
- State
- PA
- ZIP
- 19147
- Mailing
- 175 COMMERCE DRIVE SUITE 200, FORT WASHINGTON, PA
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 9
- Ownership type
- A
Citations
5 citations on file for this inspection.
5(a)(1)
- Issued
- Jul 25, 2013
- Abate by
- Aug 6, 2013
- Penalty
- Initial $4,900 · Current $4,900
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to crushing and/or struck-by hazards: a) Jobsite: 320 Hunting Park Avenue - On or about 1/29/2013, the trusses on the wood frame structure of the Special Victims Unit (SVU) were not adequately braced/restrained. In addition the trusses had been loaded with two stacks of Oriented Strand Board (OSB) floor boards. The floor board stacks exceeded the maximum load which could be safely placed on properly braced trusses. An acceptable means of abatement among other methods is to: 1) Follow Building Component Safety Information (B.C.S.I.) on how to install lateral and diagonal bracing with the minimum size bracing and lateral restraint materials of 2 x 4 stress-graded lumber or approved proprietary metal restraints. 2) Follow B.C.S.I. for appropriate location to stack materials. 3) Follow B.C.S.I. for the maximum height of plywood that can safely be stacked on top of the trusses. 4) Refrain from cutting or altering any structural members of a truss unless specifically permitted by the manufacturer or truss design drawing. 5) Ensure personnel performing truss installation are properly trained in the B.C.S.I. requirements.
Recent events (3)
- — F (S) $4900
- — C (S) $4900
- — Z (S) $4900
1926.451 G01 VII
- Issued
- Jul 25, 2013
- Abate by
- Aug 2, 2013
- Penalty
- Initial $4,900 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. b) Jobsite - 300 Hunting Park Ave, Philadelphia, PA - Employees installing trusses were standing on the rail sections of the Scissors Lift thus exposed to fall hazards of approximately 10 feet without the use of fall protection. On or about 1/28/13. Note: Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (3)
- — F (S) $0
- — C (S) $4900
- — Z (S) $4900
1926.501 B01
- Issued
- Jul 25, 2013
- Abate by
- Aug 1, 2013
- Penalty
- Initial $4,900 · Current $4,900
General-duty citation text
29 CFR 1926.501(b)(1): "Unprotected sides and edges." Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. a) Jobsite: 300 Hunting Park Ave, Philadelphia PA - Employees performing work while on top of the roof were exposed to fall hazards of approximately 15 feet without conventional or alternative methods of fall protection. Observed on or about 1/28/13 and 3/7/13. b) Jobsite-300 Hunting park Ave, Philadelphia, PA - Employees framing an exterior wall were exposed to fall hazards of approximately 8 to 10 feet without any means of fall protection. On or about 1/28/13. Note: Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (3)
- — F (S) $4900
- — C (S) $4900
- — Z (S) $4900
1926.503 A01
- Issued
- Jul 25, 2013
- Abate by
- Aug 13, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(a)(1): Employer did not provide fall protection training to those employees who might be exposed to a fall hazard. a) Jobsite: 300 Hunting Park Ave, Philadelphia PA.- The employer did not provide fall protection training and information to all personnel potentially exposed to fall hazards. Observed on or about 3/7/13.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1926.1428 A03
- Issued
- Jul 25, 2013
- Abate by
- Aug 13, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1428(a)(3): The employer of the signal person did not make available the documentation ensuring that the signal operator met the Qualification Requirements of paragraph (c) of this section. a) Jobsite: 300 Hunting Park Ave, Philadelphia PA.- The employer did not have available the documentation ensuring that the signal operator was competent in the hand or radio signals. On or about 1/28/13. NOTE: Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
More inspections at Fastrack Construction, INC.
View Fastrack Construction, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 236220)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338880032.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.