Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,871Inspections Most recent open 2026-07-30 Last loaded 2026-08-03

OSHA Inspection: FLOWLINE DIVISION OF EZEFLOW USA, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of FLOWLINE DIVISION OF EZEFLOW USA, INC. in 1400 NEW BUTLER ROAD, NEW CASTLE, PA 16101 (NAICS 331210). OSHA activity number 338886237.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Flowline Division of Ezeflow USA, INC. for free Get an email when a new federal OSHA severe-injury report for Flowline Division of Ezeflow USA, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1400 NEW BUTLER ROAD
City
NEW CASTLE
State
PA
ZIP
16101
Mailing
1400 NEW BUTLER ROAD, NEW CASTLE, PA 16101
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331210
Employees
100
Ownership type
A

15 citations on file for this inspection.

1910.133 A01

Serious Gravity 1 1 instance 5 exposed
Issued
Aug 9, 2013
Abate by
Sep 5, 2013
Penalty
Initial $3,000 · Current $2,250 Reduced
29 CFR 1910.133(a)(1): Protective eye equipment was not required where there was a reasonable probability of injury that could be prevented by such equipment:     a.) Flowline Division of Ezeflow USA, Inc., 1400 New Butler Road, New Castle, PA, Warehouse building-nitric acid dip tank-machining area, on or about April 15th 2013, and times prior thereto:  Company employees potentially exposed to eye and face hazards from acids and caustic liquids while conducting dipping operations were not provided safety goggles or other appropriate forms of eye/face protection.
Recent events (2)
  • · I (S) $2250
  • · Z (S) $3000

1910.132 A

Serious Gravity 1 1 instance 5 exposed
Issued
Aug 9, 2013
Abate by
Sep 5, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered:    a.) Flowline Division of Ezeflow USA, Inc., 1400 New Butler Road, New Castle, PA, Warehouse building-nitric acid dip tank-machining area, on or about April 15th 2013, and times prior thereto:  Company employees potentially exposed to body and extremity hazards while conducting dipping operations with acids and caustic liquids were not provided an apron or similar form of personal protective equipment.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.132 D01

Serious Gravity 1 1 instance 25 exposed
Issued
Aug 9, 2013
Abate by
Sep 5, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE):    a.) Flowline Division of Ezeflow USA, Inc., 1400 New Butler Road, New Castle, PA, Warehouse building-nitric acid dip tank-machining area, on or about April 15th 2013, and times prior thereto:  The employer did not complete personal protective equipment hazard assessments for all of the job processes performed in the warehouse facility.  A hazard assessment was not conducted where employees were potentially exposed to acid and caustic liquids during dipping operations conducted in the machining area of the warehouse.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.138 A

Serious Gravity 1 1 instance 5 exposed
Issued
Aug 9, 2013
Abate by
Sep 5, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.138(a): The employer did not select and require employee(s) to use appropriate hand protection when employees' hands were exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasion; punctures; chemical burns; thermal burns; and harmful temperature extremes:  a.) Flowline Division of Ezeflow USA, Inc., 1400 New Butler Road, New Castle, PA, Main building-Degreaser area, on or about April 15th 2013, and times prior thereto:  Company employees were potentially exposed to skin absorption hazards of n-Propyl Bromide due to a lack of hand protection at various points of the degreasing operation.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.141 A03 I

Other-than-serious 8 instances 150 exposed
Issued
Aug 9, 2013
Abate by
Sep 5, 2013
Penalty
Initial $3,000 · Current $0 Reduced
29 CFR 1910.141(a)(3)(i): Places of employment were not kept clean to the extent that the nature of the work allowed:       a.) Flowline Division of Ezeflow USA, Inc., 1400 New Butler Road, New Castle, PA, Main building-Lunch room, on or about February 14th 2013, and times prior thereto:  Wipe samples were obtained from lunch tables, and a microwave in the Main building break area and a work station in the Marking department.  Analytical results indicated the presence of toxic metals, as follows:      1.)Main Building, Lunch Table next to degreasing area(AM):  33.3810 ug Chromium Metal and Insoluble Salts, 10.9210 ug Copper, 395.3100 ug Iron Oxide, 4.9360 ug Manganese, 40.8620 ug Nickel, 70.5710 ug Zinc Oxide      2.)Main Building, Lunch Table next to inspection area(AM):  20.3720 ug Chromium Metal and Insoluble Salts, 6.8990 ug Copper, 306.7860 ug Iron Oxide, 5.0350 ug Manganese,       3.)Main Building, Lunch Table next to entry door plants main floor(AM):  21.7240 ug Chromium Metal and Insoluble Salts, 11.3020 ug Copper, 367.0020 ug Iron Oxide, 4.4360 ug Manganese, 35.1200 ug Nickel,      4.)Main Building, Lunch Table next to Locker Room(PM):  72.5710 ug Iron Oxide      5.)Main Building, Middle Microwave on coffee bench(PM):  7.8740 ug Copper, 42.1810 ug Iron Oxide      6.) Main Building, Marking Department, Workbench with cardboard:  133.1820 ug Chromium Metal and Insoluble Salts, 183.2380 ug Copper, 1225.7360 ug Iron Oxide, 16.1090 ug Manganese, 422.6660 ug Nickel      7.) Main Building, Marking Department, Workbench with no cardboard:  14.2990 ug Chromium Metal and Insoluble Salts, 12.9130 ug Copper, 106.8830 ug Iron Oxide, 32.7510 ug Nickel      8.) Main Building, Marking Department, Work shelf on cardboard side:  140.0750 ug Chromium Metal and Insoluble Salts, 40.2120 ug Copper, 2418.8840 ug Iron Oxide, 17.6050 ug Manganese, 134.1910 ug Nickel, 77.9300 ug Zinc Oxide
Recent events (2)
  • · I (O) $0
  • · Z (S) $3000

1910.141 G04

Other-than-serious 1 instance 20 exposed
Issued
Aug 9, 2013
Abate by
Sep 5, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.141(g)(4): Food or beverages were stored in area(s) exposed to toxic material(s):      a.) Flowline Division of Ezeflow USA, Inc., 1400 New Butler Road, New Castle, PA, Main building-Marking department, on or about February 12th 2013, and times prior thereto:  Company employees stored beverage bottles, lunch coolers, and food next to and around chemical containers contaminated with chemical residue.  These chemicals included, but were not limited to, Electrolyte 59-L and Electrolyte 95 NC.
Recent events (2)
  • · I (O) $0
  • · Z (S) $0

1910.242 B

Serious Gravity 1 1 instance 50 exposed
Issued
Aug 9, 2013
Abate by
Sep 5, 2013
Penalty
Initial $3,000 · Current $2,250 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:      a.) Flowline Division of Ezeflow USA, Inc., 1400 New Butler Road, New Castle, PA, Warehouse building-CNC Machining area, on or about February 12th, 2013, and times prior thereto:  Company employees were utilizing compressed air to blow water and dust off of their hands and pieces of equipment.  The compressed air at the CNC machine was set at 83 p. s. i.
Recent events (2)
  • · I (S) $2250
  • · Z (S) $3000

1910.1000 A02

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 9, 2013
Abate by
Oct 18, 2013
Penalty
Initial $6,000 · Current $4,500 Reduced

Hazardous substances 0560

29 CFR 1910.1000(a)(2): Employee(s) were exposed to an airborne concentration of Carbon Monoxide listed in Table Z-1 in excess of the 8 hour Time Weighted Average concentration of 50 parts per million:      a.) Flowline Division of Ezeflow USA, Inc., 1400 New Butler Road, New Castle, PA, Production Areas on Hyster brand powered industrial truck (Serial # B010B05832J), on or about February 14th, 2013, and times prior thereto:  A Company employee was exposed to Carbon Monoxide at a time weighted average (TWA) of 56 parts per million (ppm), which was approximately 1.1 times the Permissible Exposure Limit (PEL) of 50 ppm.  The exposure level was derived from one sample collected over 425 minutes and assumed zero exposure for the remaining work shift.
Recent events (2)
  • · I (S) $4500
  • · Z (S) $6000

1910.1000 E

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 9, 2013
Abate by
Oct 18, 2013
Penalty
Initial $0 · Current $0

Hazardous substances 0560

29 CFR 1910.1000(e): Feasible administrative or engineering controls were not determined and implemented to achieve compliance with the limits prescribed in 29 CFR 1910.1000(a) through (d):  a.) Flowline Division of Ezeflow USA, Inc., 1400 New Butler Road, New Castle, PA, Production Areas on Hyster brand powered industrial truck (Serial # B010B05832J), on or about February 14th, 2013, and times prior thereto:  A Company employee was exposed to Carbon Monoxide at a time weighted average (TWA) of 56 parts per million (ppm), which was approximately 1.1 times the Permissible Exposure Limit (PEL) of 50 ppm.  The exposure level was derived from one sample collected over 425 minutes and assumed zero exposure for the remaining work shift.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.134 D01 III

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 9, 2013
Abate by
Oct 18, 2013
Penalty
Initial $0 · Current $0

Hazardous substances 0560

29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminants chemical state and physical form:  a.) Flowline Division of Ezeflow USA, Inc., 1400 New Butler Road, New Castle, PA, Production Areas on Hyster brand powered industrial truck (Serial # B010B05832J), on or about February 14th, 2013, and times prior thereto:  A forklift operator was exposed to Carbon Monoxide at a 8 hour time weighted average (TWA) of 56 parts per million (ppm), which was approximately 1.1 times the Permissible Exposure Limit (PEL) of 50 ppm.  The company had not previously conducted air monitoring to determine the forklift operators Carbon Monoxide exposure.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.178 P01

Serious Gravity 5 2 instances 150 exposed
Issued
Aug 9, 2013
Abate by
Sep 5, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been  taken out of service until restored to safe operating condition(s):    a.) Flowline Division of Ezeflow USA, Inc., 1400 New Butler Road, New Castle, PA, Production areas, on or about February 14th  2013, and times prior thereto:  Company employees utilized liquid propane powered Hyster forklifts throughout their production areas.  Hyster forklift (Serial # B010B05832J) was exhausting large amounts of Carbon Monoxide and needed mechanical repair.    b.) Flowline Division of Ezeflow USA, Inc., 1400 New Butler Road, New Castle, PA, Production areas, on or about February 14th  2013, and times prior thereto:  Company employees utilized liquid propane powered Hyster and Clark forklifts to move products throughout the production areas.  Company employees were operating a propane powered forklift (Hyster brand; Serial #B177B020397) with no latch used to secure the propane cylinder.  On some forklifts the propane cylinders were unlatched on this particular forklift the latch was broken off completely.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.1025 H01

Serious Gravity 1 1 instance 20 exposed
Issued
Aug 9, 2013
Abate by
Sep 5, 2013
Penalty
Initial $3,000 · Current $2,250 Reduced

Hazardous substances 1591

29 CFR 1910.1025(h)(1): All surfaces were not maintained as free as practicable of accumulations of lead:     a.) Flowline Division of Ezeflow USA, Inc., 1400 New Butler Road, New Castle, PA, on or about February 14th, 2013, and times prior thereto: Paint chips containing lead were present on the work benches in the Marking Deaprtment.  Three bulk samples of paint were collected from the areas listed below and were analyzed to determine if lead was present.       1.) Sample 1(Flow-013)-Paint chip on cardboard side of the shelf in the marking area.   2.) Sample 2 (Flow-14)-Paint chip on the upper wall in the marking area.   3.) Sample 3 (Flow-015)-Paint chip on column 11 in the marking area.       Analytical results for lead indicated the following:   1.) Sample 1(Flow-013)- 0.64 %   2.) Sample 2 (Flow-14)- 0.02 %   3.) Sample 3 (Flow-015)- 1.72%
Recent events (2)
  • · I (S) $2250
  • · Z (S) $3000

1910.1025 L01 I

Serious Gravity 1 1 instance 20 exposed
Issued
Aug 9, 2013
Abate by
Sep 26, 2013
Penalty
Initial $0 · Current $0

Hazardous substances 1591

29 CFR 1910.1025(l)(1)(i): Employee(s) working in an area where there is potential exposure to airborne lead at any level were not informed of the content of Appendices A and B of 29 CFR 1910.1025:   a.) Flowline Division of Ezeflow USA, Inc., 1400 New Butler Road, New Castle, PA, Marking department, on or about February 14th, 2013, and times prior thereto:  Company employees in the Marking department were potentially exposed to lead in lead based paint which had fallen from overhead panels onto employee workstations.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.1200 F05 I

Serious Gravity 1 1 instance 15 exposed
Issued
Aug 9, 2013
Abate by
Sep 5, 2013
Penalty
Initial $3,000 · Current $2,250 Reduced
29 CFR 1910.1200(f)(5)(i): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein:    a.) Flowline Division of Ezeflow USA, Inc., 1400 New Butler Road, New Castle, PA, Descaling area tank # 9, on or about February 14th, 2013, and times prior thereto:  The # 9 dip tank in the passivating descaling area was not labeled to identify the chemical(s) contained within the tank.
Recent events (2)
  • · I (S) $2250
  • · Z (S) $3000

1910.1200 F05 II

Serious Gravity 1 1 instance 20 exposed
Issued
Aug 9, 2013
Abate by
Sep 5, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(5)(ii): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the appropriate hazard warnings:  (a) Flowline Division of Ezeflow USA, Inc., 1400 New Butler Road, New Castle, PA, Passivating descaling area tank # 9, on or about February 14th, 2013, and times prior thereto:  The # 9 dip tank in the passivating descaling area was not labeled to identify the hazard warnings of the chemical(s) contained within the tank.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

View Flowline Division of Ezeflow USA, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338886237.