Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: METO LIFT, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of METO LIFT, INC. in 556 COMMERCE ST., FRANKLIN LAKES, NJ 07417 (NAICS 333999). OSHA activity number 338906043.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Meto Lift, INC. — free Get an email when a new federal OSHA severe-injury report for Meto Lift, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
METO LIFT, INC.
Site address
556 COMMERCE ST.
City
FRANKLIN LAKES
State
NJ
ZIP
07417
Mailing
556 COMMERCE ST., FRANKLIN LAKES, NJ 07417
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333999
Employees
11
Ownership type
A

15 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 2 instances 3 exposed
Issued
Jun 18, 2013
Abate by
Nov 30, 2013
Penalty
Initial $2,000 · Current $1,250 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees     (a)Polishing Area: Employees operated grinding and polishing machines without local ventilation, on or about February 6, 2013.     (b)Polishing Area: The EBM-4 Booth Module was being used to capture dusts that were created during grinding and polishing of stainless steel. The dust tested positive for explosivity. The dust collector, which was installed indoors, was not intended to be used to collect explosive or combustible dusts, on or about February 6, 2013.
Recent events (2)
  • — I (S) $1250
  • — Z (S) $2000

1910.134 E01

Serious Gravity 1 1 instance 3 exposed
Issued
Jun 18, 2013
Abate by
Sep 1, 2013
Penalty
Initial $1,200 · Current $1,000 Reduced
29 CFR 1910.134(e)(1):     The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:     (a)Establishment: Employees that polished and welded Stainless Steel were required to use a respirator and a medical evaluation was not provided, on or about February 6, 2013.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $1200

1910.151 C

Other-than-serious 1 instance 1 exposed
Issued
Jun 18, 2013
Penalty
Initial $2,000 · Current $0 Reduced
29 CFR 1910.151(c): Where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body shall be provided within the work area for immediate emergency use.     (a) Machine Shop Area: The employer did not provide an eyewash where employees added water to the battery for the forklift, thus exposing employees to a prolonged corrosive chemical exposure to the eyes, on or about February 6, 2013.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2000

1910.1052 I02

Other-than-serious 1 instance 2 exposed
Issued
Jun 18, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1052(i)(2):     If it is reasonably foreseeable that an employee's eyes may contact solutions containing 0.1 percent or greater MC (for example through splashes, spills or improper work practices), the employer shall provide appropriate eyewash facilities within the immediate work area for emergency use, and shall ensure that affected employees use those facilities when necessary.     (1) Welding Area: The employer did not provide an eyewash in the welding area where employees spray from an aerosol can Weld-Aid Nozzle Kleen #2 for welding. The product contains about 85 % Methylene Chloride, on or about February 6, 2013.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.1026 D01

Other-than-serious 1 instance 3 exposed
Issued
Jun 18, 2013
Penalty
Initial $2,000 · Current $0 Reduced
29 CFR 1910.1026(d)(1): The employer with a workplace or work operation covered by this standard did not determine the 8-hour time-weighted average exposure for each employee exposed to chromium (VI):      (a)Establishment: Employees that welded and polished Stainless Steel which generated fume and dust that contained Hexavalent Chromium were not monitored to determine their exposure, on or about February 6, 2013.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2000

1910.1052 D01 I B

Other-than-serious 1 instance 3 exposed
Issued
Jun 18, 2013
Penalty
Initial $2,000 · Current $0 Reduced
29 CFR 1910.1052(d)(1)(i)(B):     Taking personal breathing zone air samples that are representative of each employee's exposure.    (a)Establishment: Employees sprayed Weld-Aid Nozzle Kleen #2, which contains 85% Methylene Chloride, during welding of Stainless Steel but were not monitored to determine their exposure, on or about February 6, 2013.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2000

1910.1200 E01

Serious Gravity 5 1 instance 3 exposed
Issued
Jun 18, 2013
Abate by
Sep 1, 2013
Penalty
Initial $2,000 · Current $1,250 Reduced
29 CFR 1910.1200(e)(1):     Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:      (a)Establishment: A written Hazard Communication Program was not developed, implemented or maintained for employees who polished, or welded Stainless Steel and sprayed Weld-Aid Nozzle Kleen #2, which contains 85% methylene Chloride. These processes created combustible dusts and hazardous chemicals including but not limited to Hexavalent Chromium, Nickel, Copper, and Methylene Chloride on or about February 6, 2013.
Recent events (2)
  • — I (S) $1250
  • — Z (S) $2000

1910.1200 F05 II

Serious Gravity 5 1 instance 3 exposed
Issued
Jun 18, 2013
Abate by
Sep 1, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(5)(ii): Appropriate hazard warnings, or alternatively, words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals, and which, in conjunction with the other information immediately available to employees under the hazard communication program, will provide employees with the specific information regarding the physical and health hazards of the hazardous chemical.     (a)Establishment:  Employees polished and/or welded Stainless Steel and sprayed Weld-Aid Nozzle Kleen #2, which contains 85% methylene Chloride. These processes create combustible dusts and hazardous chemicals including but not limited to Hexavalent Chromium, Nickel, Copper, Brown Aluminum Oxide and Methylene Chloride but were not provided with appropriate labels, on or about February 6, 2013.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 G01

Serious Gravity 5 1 instance 3 exposed
Issued
Jun 18, 2013
Abate by
Sep 1, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(1):     Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use     (a)Establishment: Material Safety Data Sheets were not made available to employees who polished and welded Stainless Steel and sprayed Weld-Aid Nozzle Kleen #2, which contains 85% Methylene Chloride. These processes create combustible dusts and expose employees to hazardous chemicals including but not limited to Hexavalent Chromium, Nickel, Copper, Aluminum Oxide and Methylene Chloride, but Safety Data Sheets were not available on or about February 6, 2013.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 H01

Serious Gravity 5 1 instance 3 exposed
Issued
Jun 18, 2013
Abate by
Sep 2, 2013
Penalty
Initial $2,000 · Current $1,500 Reduced
29 CFR 1910.1200(h)(1):     Employers shall provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new chemical hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and safety data sheets.     (a)Establishment: Employees polished and welded Stainless Steel and sprayed aerosol products.These activities generated hazardous chemicals including but not limited to Combustible Metal Dusts, Hexavalent Chromium, Nickel, Copper, Aluminum Oxide and Methylene Chloride but employees were not provided effective information and training on the hazards of the chemicals with which they worked, on or about February 6, 2013.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2000

1910.1052 L01

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 18, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1052(l)(1):   The employer shall provide information and training for each affected employee prior to or at the time of initial assignment to a job involving potential exposure to MC.  (a) Welding Area: The employer did not communicate the hazards of Methylene Chloride to employees who spray from an aerosol can Weld-Aid Nozzle Kleen #2 during welding. The product contains 85 % Methylene Chloride, on or about February 6, 2013.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1026 L01 III

Serious Gravity 5 1 instance 3 exposed
Issued
Jun 18, 2013
Abate by
Sep 1, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1026(l)(1)(iii): The employer did not include chromium (VI) in the hazard communication program established to comply with the Hazard Communication Standard (HCS), ensure that each employee had access to labels on containers of chromium (VI) and to safety data sheets, and was trained in accordance with the requirements of HCS and 29 CFR 1910.1026:     (a)Establishment: Employees welded and polished Stainless Steel, the fume and dust contains hexavalent chromium, but were not provided effective information and training on the hazards of hexavalent chromium, on or about February 6, 2013.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 C01

Other-than-serious 1 instance 3 exposed
Issued
Jun 18, 2013
Abate by
Sep 1, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:    (a)Establishment: Employees that polished, and welded Stainless Steel were required to use a respirator, but no written Respiratory Protection Program had been established, on or about February 6, 2013.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 K03

Other-than-serious 1 instance 3 exposed
Issued
Jun 18, 2013
Abate by
Sep 1, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.134(k)(3): Training was not provided prior to requiring employees to use a respirator in the workplace:    (a)Establishment: Employees that polished, and welded Stainless Steel were required to use a respirator, but training was not provided to employees, on or about February 6, 2013.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 F01

Other-than-serious 1 instance 3 exposed
Issued
Jun 18, 2013
Abate by
Sep 1, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f)(1): The employer did not ensure that employees required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT):    (a)Establishment: Employees that polished, and welded Stainless Steel were required to use a respirator, but employees were not fit tested, on or about February 6, 2013.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Meto Lift, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338906043.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.