TAMUNING, GU —
OSHA Inspection: INTER-TECH BUILDERS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of INTER-TECH BUILDERS, INC. in GYPSUM AND CEMENT BOARD FIRE EXIT REPLACEMENT PROJECT HILTON GUAM HOTEL EAST TOWER, TAMUNING, GU 96913 (NAICS 238310). OSHA activity number 338908742.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- INTER-TECH BUILDERS, INC.
- Site address
- GYPSUM AND CEMENT BOARD FIRE EXIT REPLACEMENT PROJECT HILTON GUAM HOTEL EAST TOWER
- City
- TAMUNING
- State
- GU
- ZIP
- 96913
- Mailing
- PO BOX 12524, TAMUNING, GU 96931
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238310
- Employees
- 10
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.95 A
- Issued
- Apr 5, 2013
- Penalty
- Initial $880 · Current $880
General-duty citation text
29 CFR 1926.95(a): Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, were not provided, used, and maintained in a sanitary and reliable condition wherever it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact: (a) At the seventh floor exit door to the stairs on the south side exterior of the Premium Tower on or about February 20, 2013, eye protection was not used while breaking out existing cement or gypsum boards and while using a drill to install screws into new cement or gypsum boards. INTER-TECH BUILDERS, INC. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD 29 CFR 1926.95(A) WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 314656489, CITATION NUMBER 1, ITEM NUMBER 1, ISSUED ON JUNE 3, 2010, WITH RESPECT TO A WORKPLACE LOCATED AT THE CINNABON STORE PROJECT IN THE MICRONESIA MALL, DEDEDO, GUAM. INTER-TECH BUILDERS, INC. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD 29 CFR 1926.95(A) WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 312245301, CITATION NUMBER 1, ITEM NUMBER 1, ISSUED ON AUGUST 28, 2008, WITH RESPECT TO A WORKPLACE LOCATED AT THE HILTON GUAM RESTROOM RENOVATION PROJECT, TUMON, GUAM.
Recent events (1)
- — Z (R) $880
1926.404 B01 I
- Issued
- Apr 5, 2013
- Abate by
- Apr 15, 2013
- Penalty
- Initial $220 · Current $220
General-duty citation text
29 CFR 1926.404(b)(1)(i): The employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors: (a) At the seventh floor exit door to the stairs on the south side exterior of the Premium Tower on or about February 20, 2013, there was no assured equipment grounding conductor program or ground-fault circuit-interrupter protection for employees that used a 110 VAC Makita drill to install screws into cement or gypsum boards. The drill was powered through an extension cord that was plugged into a outlet, located in the hallway on the seventh floor of the Premium Tower. INTER-TECH BUILDERS, INC. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD 29 CFR 1926.404(B)(1)(I) WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 312931751, CITATION NUMBER 1, ITEM NUMBER 1, ISSUED ON AUGUST 19, 2009, WITH RESPECT TO A WORKPLACE LOCATED AT THE MACY'S MEN'S STORE AT THE MIRCRONESIA MALL, DEDEDO, GUAM. INTER-TECH BUILDERS, INC. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD 29 CFR 1926.404(B)(1)(I) WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 313117830, CITATION NUMBER 1, ITEM NUMBER 1, ISSUED ON JULY 14, 2009, WITH RESPECT TO A WORKPLACE LOCATED AT THE MACY'S MEN'S CHILDREN'S EXPANSION AT THE MIRCRONESIA MALL, DEDEDO, GUAM.
Recent events (1)
- — Z (R) $220
1926.405 A02 II I
- Issued
- Apr 5, 2013
- Abate by
- Apr 15, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(a)(2)(ii)(I): Flexible cords and cables were not protected from damage: (a) At the seventh floor exit door to the stairs on the south side exterior of the Premium Tower on or about February 20, 2013, an extension cord was pinched between the bottom of the door and the weather stripping on the floor. The outside insulation was cut on the cord. The cord powered a 110 VAC Makita drill, used on the exterior stairway landing, and was plugged into a outlet, located in the hallway on the seventh floor.
Recent events (1)
- — Z (O) $0
More inspections at Inter-Tech Builders, INC.
View Inter-Tech Builders, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238310)
More inspections in GU
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338908742.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.