Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FIRST AMERICA METAL CORPORATION

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of FIRST AMERICA METAL CORPORATION in 1000 E. ARMSTRONG, MORRIS, IL 60450 (NAICS 423930). OSHA activity number 338909591.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch First America Metal Corporation — free Get an email when a new federal OSHA severe-injury report for First America Metal Corporation is published. One employer, no account, unsubscribe in one click.
Site address
1000 E. ARMSTRONG
City
MORRIS
State
IL
ZIP
60450
Mailing
1000 E. ARMSTRONG, MORRIS, IL 60450
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423930
Employees
13
Ownership type
A

4 citations on file for this inspection.

1910.147 C01

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 19, 2013
Abate by
Sep 5, 2013
Penalty
Initial $2,000 · Current $1,400 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:   The employer failed to develop an energy control program that includes but is not limited to employee training and documented procedures to control hazardous energy sources when working on equipment such as but not limited to conveyors, baler systems, shears and electrical equipment.    Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2000

1910.178 Q07

Serious Gravity 1 5 instances 4 exposed
Issued
Jul 19, 2013
Abate by
Sep 5, 2013
Penalty
Initial $1,200 · Current $840 Reduced
29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service:    The employer failed to inspect the trucks prior to placing them in operation.  1- 50 Hyster (model 550XL serial C187V160785) Horn was not operational. 2- Hyundai (model 35CYA80-00004 serial H3411491) Lights and horn not operational. 3- Toyota (model 7FGCU25 serial 77419) Lights and horn not operational. 4- 6000 Komatsu (model FG30SH1-14 serial 593789A) Horn not operational.  5- Toyota (model 7FGCU35 serial 63145) Horn not operational.    Abatement certification is required for this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (2)
  • — I (S) $840
  • — Z (S) $1200

1910.212 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 19, 2013
Abate by
Sep 5, 2013
Penalty
Initial $2,000 · Current $1,400 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:   The employer did not use adequate machine guarding to protect employees exposed to cuts, lacerations, fractures and amputations when using the TongXing Tx model Q43-250 serial 120224-548 shears.     Abatement documentation is required for for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2000

1910.178 L01 I

Repeat Gravity 5 1 instance 3 exposed
Issued
Jul 19, 2013
Abate by
Sep 5, 2013
Penalty
Initial $3,200 · Current $2,240 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):  The employer authorized production employees to operate the powered industrial trucks failing to provide training that included a practical training, (demonstration performed by the trainer and practical exercises performed by the trainee) and an evaluation of the operators performance in the workplace.     Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).     First America Metal Corporation was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.178(l)(1), which was contained in OSHA inspection number 312724420, citation number 01, item number 003 and was affirmed as a final order on May 7, 2009 with respect to a workplace located at 113 Industrial Dr. Minooka IL 60447
Recent events (2)
  • — I (R) $2240
  • — Z (R) $3200

View First America Metal Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338909591.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.