OSHA Inspection: A&R ROOFING, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of A&R ROOFING, INC. in 5800 NW 104 AVE, MIAMI, FL 33178 (NAICS 238160). OSHA activity number 338915598.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch A&R Roofing, INC. — free Get an email when a new federal OSHA severe-injury report for A&R Roofing, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
A&R ROOFING, INC.
Site address
5800 NW 104 AVE
City
MIAMI
State
FL
ZIP
33178
Mailing
1352 S KILLIAN DR, WEST PALM BEACH, FL 33403
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

2 citations on file for this inspection.

1926.501 B11

Serious Gravity 10 1 instance 5 exposed
Issued
Feb 28, 2013
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems:    On or about 02-21-13, employees were working on a steep roof without any type of fall protection system.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1926.1053 B01

Serious Gravity 10 1 instance 5 exposed
Issued
Feb 28, 2013
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:    On or about 02-21-13, five employees were accessing a roof with a ladder that did not extend three feet above the landing surface.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

View A&R Roofing, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338915598.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.