Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: LUMMUS CORPORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of LUMMUS CORPORATION in 225 BOURNE BLVD, SAVANNAH, GA 31408 (NAICS 333298). OSHA activity number 338921281.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Lummus Corporation — free Get an email when a new federal OSHA severe-injury report for Lummus Corporation is published. One employer, no account, unsubscribe in one click.
Establishment
LUMMUS CORPORATION
Site address
225 BOURNE BLVD
City
SAVANNAH
State
GA
ZIP
31408
Mailing
P.O. BOX 929, POOLER, GA 31322
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333298
Employees
139
Ownership type
A

2 citations on file for this inspection.

1910.157 C01

Serious Gravity 1 2 instances 1 exposed
Issued
May 29, 2013
Abate by
Jun 24, 2013
Penalty
Initial $2,700 · Current $1,620 Reduced
29 CFR 1910.157(c)(1): The employer shall provide portable fire extinguishers and shall mount, locate and identify them so that they are readily accessible to employees without subjecting the employees to possible injury.   A)  In the plant, on or about February 27, 2013, and at times prior to, fire extinguishers were blocked with boxes and other materials at the back aisle area, exposing employees to fire hazards in case of an emergency situation.  ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
  • — I (S) $1620
  • — Z (S) $2700

1910.252 B02 III

Serious Gravity 5 1 instance 2 exposed
Issued
May 29, 2013
Abate by
Jun 24, 2013
Penalty
Initial $3,600 · Current $2,160 Reduced
29 CFR 1910.252(b)(2)(iii): Protection from arc welding rays. Where the work permits, the welder should be enclosed in an individual booth painted with a finish of low reflectivity such as zinc oxide (an important factor for absorbing ultraviolet radiations) and lamp black, or shall be enclosed with noncombustible screens similarly painted. Booths and screens shall permit circulation of air at floor level. Workers or other persons adjacent to the welding areas shall be protected from the rays by noncombustible or flameproof screens or shields or shall be required to wear appropriate goggles.    A)  In the plant, on or about February 27, 2013, and at times prior to, an employee was observed welding without flash curtains or screens in the balancing station, exposing employees 4-6ft away to flash burn.   Employees pickup parts from the rack in the balancing station area.  ABATEMENT CERTIFICATION AND DOCUMENTATION ARE REQUIRED.