OAK CREEK, WI —
OSHA Inspection: APPLIED PLASTICS COMPANY, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of APPLIED PLASTICS COMPANY, INC. in 7320 S. 6TH, OAK CREEK, WI 53154 (NAICS 326122). OSHA activity number 338922974.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- APPLIED PLASTICS COMPANY, INC.
- Site address
- 7320 S. 6TH
- City
- OAK CREEK
- State
- WI
- ZIP
- 53154
- Mailing
- 7320 S. 6TH, OAK CREEK, WI 53154
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326122
- Employees
- 80
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.217 C01 I
- Issued
- Apr 5, 2013
- Abate by
- Apr 11, 2013
- Penalty
- Initial $4,900 · Current $4,000 Reduced
General-duty citation text
29 CFR 1910.217(c)(1)(i): The employer did not provide and ensure the usage of point of operation guards or properly applied point of operation devices on every operation performed on mechanical power press(es). (a) The employer failed to ensure that the guard on a 3 ton mechanical power press prevented employees from reaching to point of operation. This exposed employees to amputation hazards.
Recent events (2)
- — I (S) $4000
- — Z (S) $4900
1910.217 E01 I
- Issued
- Apr 5, 2013
- Abate by
- May 17, 2013
- Penalty
- Initial $2,380 · Current $0 Reduced
General-duty citation text
29 CFR 1910.217(e)(1)(i): The employer did not maintain a certification record of inspections which includes the date of inspection, the signature of the person who performed the inspection and the serial number, or other identifier, of the power press that was inspected. (a) The employer failed to maintain a certified record of inspections for the mechanical power press, to ensure that they were properly inspected. This exposed employees to amputation hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $2380
More inspections at Applied Plastics Company, INC.
View Applied Plastics Company, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 326122)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338922974.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.