MILTON, FL —
OSHA Inspection: EMERALD COAST TRUSS LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of EMERALD COAST TRUSS LLC in 5817 COMMERCE ROAD, MILTON, FL 32583 (NAICS 321214). OSHA activity number 338929276.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EMERALD COAST TRUSS LLC
- Site address
- 5817 COMMERCE ROAD
- City
- MILTON
- State
- FL
- ZIP
- 32583
- Mailing
- P.O. BOX 888, MILTON, FL 32572
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321214
- Employees
- 25
- Ownership type
- A
Citations
10 citations on file for this inspection.
1910.22 A01
- Issued
- Aug 7, 2013
- Abate by
- Aug 15, 2013
- Penalty
- Initial $4,200 · Current $2,520 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition. a. On or about February 26, 2013, the speed cut saw area had excessive buildup of saw dust, exposing the employee to fire hazards. b. On or about February 26, 2013, main saw area had excessive buildup of saw dust, exposing the employee to fire hazards. Abatement Certification and Documentation are not required
Recent events (2)
- — I (S) $2520
- — Z (S) $4200
1910.147 C04 I
- Issued
- Aug 7, 2013
- Abate by
- Aug 15, 2013
- Penalty
- Initial $3,500 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a. On or about February 25, 2013, the employer did not utilize their specific procedures developed for employees that utilized lockout tagout devices.
Recent events (2)
- — I (S) $2100
- — Z (S) $3500
1910.147 C05 II B
- Issued
- Aug 7, 2013
- Abate by
- Aug 15, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(5)(ii)(B): Lockout and tagout devices were not standardized within the facility in at least one of the following criteria: color; shape; or size: a. On or about February 25, 2013, the employer did not have standardized locks. Abatement Certification and Documentation are not required
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C06 I
- Issued
- Aug 7, 2013
- Abate by
- Aug 15, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a. On or about February 25, 2013, the employer did not conduct a periodic inspection of the energy control program since 2007. Abatement Certification and Documentation are not required
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C07 I A
- Issued
- Aug 7, 2013
- Abate by
- Aug 15, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation: a. On or about February 25, 2013, all authorized employes did not receive training in the recognition of the lockout tagout program. Abatement Certification and Documentation are not required
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 F02
- Issued
- Aug 7, 2013
- Abate by
- Aug 15, 2013
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: a. On or about February 25, 2013, three breaker panels were not labelled as to their purpose. Abatement Certification and Documentation are not required
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1910.305 B01
- Issued
- Aug 7, 2013
- Abate by
- Aug 15, 2013
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.305(b)(1): Unused openings in boxes, cabinets, or fittings were not effectively closed: a. On or about February 25, 2013, three electrical panels had unused openings that were not closed.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1910.141 D02 III
- Issued
- Aug 7, 2013
- Abate by
- Aug 15, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.141(d)(2)(iii): Lavatories were not provided with hand soap or similar cleansing agent: a. On or about February 27, 2013, the shop bathroom was unsanitary in that it had not been cleaned and did not have hand soap or towles. Abatement Certification and Documentation are not required
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.151 C
- Issued
- Aug 7, 2013
- Abate by
- Aug 15, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: a. On or about February 27, 2013, the eyewash station bottle was empty. Abatement Certification and Documentation are not required
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 G01 II
- Issued
- Aug 7, 2013
- Abate by
- Aug 15, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: a. On or about February 25, 2013, there was not enough working space in front of three electrical panels because the employer allowed items such as but not limited to a table, light fixtures, wheel barrow, etc to be stored in front of the panels.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Emerald Coast Truss LLC
View Emerald Coast Truss LLC's full OSHA safety record →
More inspections in this industry (NAICS 321214)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338929276.