Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RONSON MACHINE & MANUFACTURING, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of RONSON MACHINE & MANUFACTURING, INC. in 5000 EAST GEOSPACE DRIVE, INDEPENDENCE, MO 64056 (NAICS 332322). OSHA activity number 338930506.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ronson Machine & Manufacturing, INC. — free Get an email when a new federal OSHA severe-injury report for Ronson Machine & Manufacturing, INC. is published. One employer, no account, unsubscribe in one click.
Site address
5000 EAST GEOSPACE DRIVE
City
INDEPENDENCE
State
MO
ZIP
64056
Mailing
3000 SOUTH JACKSON DRIVE, INDEPENDENCE, MO 64057
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332322
Employees
50
Ownership type
A

6 citations on file for this inspection.

1910.178 P01

Other-than-serious 1 instance 1 exposed
Issued
Mar 21, 2013
Abate by
Apr 25, 2013
Penalty
Initial $2,380 · Current $0 Reduced
29 CFR 1910.178(p)(1):     Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s):    (a) The Baker forklift did not have a nonslip surface on the brake pedal and was not taken out of service until it was repaired.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2380

1910.215 A04

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 21, 2013
Abate by
Apr 25, 2013
Penalty
Initial $2,380 · Current $1,428 Reduced
29 CFR 1910.215(a)(4):     Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:    (a) Welding Station 15: The DeWalt Bench Grinder on the left grinding wheel had the tongue guard adjusted at greater than 1/8 inch.
Recent events (2)
  • — I (S) $1428
  • — Z (S) $2380

1910.215 B09

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 21, 2013
Abate by
Apr 25, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9):     The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:    (a) Welding Station 15:  The DeWalt Bench Grinder had the left wheel tongue guard adjusted at greater than 1/4 inch.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.242 B

Serious Gravity 1 1 instance 3 exposed
Issued
Mar 21, 2013
Penalty
Initial $1,785 · Current $1,250 Reduced
29 CFR 1910.242(b):     Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:    (a) Quality Area:  The air nozzle used for cleaning was greater than 30 p.s.i.
Recent events (2)
  • — I (S) $1249.5
  • — Z (S) $1785

1910.303 B02

Serious Gravity 5 2 instances 11 exposed
Issued
Mar 21, 2013
Abate by
Apr 25, 2013
Penalty
Initial $2,380 · Current $1,066 Reduced
29 CFR 1910.303(b)(2):     Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    (a) Welding Station 8: An electrical switch with knockouts was not used or installed in accordance with listing or labeling as it was used with flexible cord for a fan on/off switch and the box was not mounted to a wall or piece of machinery with rigid conduit.    (b) Machining: An electrical box with knockouts, such as, but not limited to, the electrical box by the Hyd-Mech horizontal bandsaw, was not used or installed in accordance with instructions included in the listing or labeling as the box was used as a pendant instead of mounted to a wall or piece of equipment with rigid conduit.
Recent events (2)
  • — I (S) $1066
  • — Z (S) $2380

1910.305 G02 III

Other-than-serious 1 instance 4 exposed
Issued
Mar 21, 2013
Abate by
Apr 25, 2013
Penalty
Initial $2,380 · Current $1,428 Reduced
29 CFR 1910.305(g)(2)(iii):     Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:    (a) Press Brake Area by Amada 1030:  The Dayton Pedestal fan did not have adequate strain relief as the fitting had pulled loose where the electrical cord attached to the on/off switch exposing interior wiring.    (b) Fabrication Area: The foot pedal for the Notcher CSH-220 did not have adequate strain relief as the electrical cord had pulled loose where it attached to the Notcher exposing interior wiring.
Recent events (2)
  • — I (O) $1428
  • — Z (S) $2380

View Ronson Machine & Manufacturing, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338930506.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.