FENTON, MO —
OSHA Inspection: DAVIS TOOL & DIE
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of DAVIS TOOL & DIE in 888 BOLGER COURT, FENTON, MO 63026 (NAICS 333513). OSHA activity number 338938335.
Where did this inspection happen?
- Establishment
- DAVIS TOOL & DIE
- Site address
- 888 BOLGER COURT
- City
- FENTON
- State
- MO
- ZIP
- 63026
- Mailing
- 888 BOLGER COURT, FENTON, MO 63026
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333513
- Employees
- 92
- Ownership type
- A
Citations
18 citations on file for this inspection.
1910.132 D01
- Issued
- Abate by
- Penalty
- Initial $4900.00 · Current $0.00 Reduced
8870
General-duty citation text
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE): Location: Davis Tool and Die at 888 Bolger Ct., Fenton, Missouri 63026, production bays 1-4 The employer did not assess the workplace to determine if hazards were present for all maintenance job functions which necessitated the use of personal protective equipment (PPE) such as, but not limited to, the use of personal protective equipment (PPE) to protect against electrical shock or burns while maintenance employees are working on energized equipment and while verifying electrical circuits are deenergized for maintenance purposes. The employer did not ensure that a maintenance worker was provided with and used electrically insulated gloves and nonconductive eye protection when working on or near energized equipment. A maintenance worker was working on a 480 volt W.S. Rockwell oven, s/n S 966 and was electrocuted after contacting energized components.
Recent events (3)
- — F (S) $0
- — C (S) $4900
- — Z (S) $4900
1910.137 B02 VIII
- Issued
- Abate by
- Penalty
- Initial $3500.00 · Current $2125.00 Reduced
General-duty citation text
29 CFR 1910.137(b)(2)(viii): Electrical protective equipment was not subjected to periodic electrical tests in accordance with Tables I-5 and I-6: Location: Davis Tool and Die at 888 Bolger Ct., Fenton, Missouri 63026. The employer did not ensure that electrically insulated gloves that were provided to a maintenance worker had been tested prior to first issue and every 6 months as outlined in Table I-6.
Recent events (3)
- — F (S) $2125
- — C (S) $3500
- — Z (S) $3500
1910.147 C04 II
- Issued
- Abate by
- Penalty
- Initial $4900.00 · Current $2125.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D): Location: David Tool and Die, 888 Bolger Court, Fenton, MO, 63026. For maintenance employees(s) who serviced and maintained equipment with multiple energy sources, the employer failed to ensure that clear and specific procedural steps were developed for forty-six machines, including but not limited to: a) #303, Brown & Sharpe Coordinate Measuring Machine MicroXcel PFX b) #322, Sanding/Pulsar VI c) #323, 150 Ton Press/150T-E/H Press Master d) #324, Zero Bead Blaster / D300F e) #331, W.S. Rockwell oven, s/n S966 f) #350, Forklift g) #351, Forklift Yale h) #353, Forklift NAMCO i) #354, Forklift j) #601, Okuma Vertical Machine Center MC-4VAE k) #604, Okuma Bubba Vertical Center l) #606, Okuma & Howa Millac 852V CNC Vertical Machining Center m) #615, Okuma Howa 3VA n) #616, Okuma MB-56VA High Speed Vertical Machining Center o) #617, Okuma MC-V 4020 Machine Center p) #618, Okuma MB 56VA Ace Center High Speed Vertical Maching Center q) #619, Okuma MC-V 4020 Machining Center r) #624, CNC Mill Fryer Mill MB-15 s) #626, Haas 20 HP Vertical Machining Center VF-3 t) #627, Hurco BMC 4020 Vertical Machining Center u) #628, Hurco MDL VMX24 CNC Vertical Machining Center v) #634, Big Ike Horizontal Mill Ikegai NB 110T w) #635, Big Nick Horizontal Mill Okuma MX-60 HB x) #636, Fast Eddie Horizontal Mill OKK MCH 600 y) #637, Little Ike Horizontal Mill SNK Ikegai NB11T z) #638, Big Mac Horizontal Mill Makino A81 aa) #652, Vertical Mill Man knee Mill Alliant bb) #657, Vertical Mill Man knee Mill Alliant cc) #661, Vertical Mill Man knee Mill Lagun dd) #662, Vertical Mill Man knee Mill Lagun ee) #675, Deckel Maho 50 eVolution 5 Axis Simultaneous High Speed 18,000 RPM Machining Center ff) #676, Deckel Maho 70 eVolution 5 axis Simultaneous High Speed 18,000 RPM Machining Center gg) #711, Okuma Crown S Lathe hh) #730, Okuma Millac 33TU ii) #731, Okuma Millac 33TU jj) #801, Okamoto Surface Grinder kk) #803, Okamoto Surface Grinder ll) #804, Okamoto Surface Grinder 16-32 ST mm)#811, Corue Pin Grinder nn) #901, EDM Sinker - Elox CNC Heritage 12(Electronic Discharge Machine) oo) #905, Matchburn EDM - Cinncinnati Milacon (Electronic Discharge Machine) pp) #908, EDM Sinker - Charmilles Roboform 54P (Electronic Discharge Machine) qq) #909, EDM Sinker - Agie Mondo Star 50 (Electronic Discharge Machine) rr) #910, EDM Sinker - Charmilles Roboform 550 (Electronic Discharge Machine) ss) #911, Charmilles F0550 w/ DD 1662 Toolchanger tt) #922, Wire EDM - Agie Progress 3 (Electronic Discharge Machine) Such typical hazardous energy sources include, but may not be limited to, mechanical (e.g., power transmission apparatus, counterbalances, springs, pressure, and gravity), pneumatic, hydraulic, electrical, chemical, and thermal (high or low temperature) energies that could cause injury to employees.
Recent events (3)
- — F (S) $2125
- — C (S) $4900
- — Z (S) $4900
1910.151 C
- Issued
- Abate by
- Penalty
- Initial $3500.00 · Current $2125.00 Reduced
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: Location: Davis Tool & Die at 888 Bolger Ct, Fenton, MO 63026 An adequate eyewash station was not provided in the immediate area for emergency use for maintenance employees who charged and serviced the forklift batteries.
Recent events (3)
- — F (O) $2125
- — C (S) $3500
- — Z (S) $3500
1910.178 L04 III
- Issued
- Abate by
- Penalty
- Initial $2100.00 · Current $2125.00
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: Location: Davis Tool & Die, 888 Bolger Ct, Fenton, MO 63026 On or about March 6, 2013, it had been more than four years since forklift operators had performance evaluations.
Recent events (3)
- — F (O) $2125
- — C (S) $2100
- — Z (S) $2100
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $4900.00 · Current $2125.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by: At the time of the inspection, two vertical band saws had no guards to cover unused portions of the blades: a) #404 Marvel Band Saw, series 81A located in bay 4, up to 6 inches of unused portion of vertical saw blade is not guarded when employees cut 2 inch pieces of steel; b) #402 Marvel Band Saw, located in bay 4 is used to cut small metal pieces at sizes ranging from 1 ½ inches and larger, leaving approximately 5 inches of unused blade exposed ;
Recent events (3)
- — F (S) $2125
- — C (S) $4900
- — Z (S) $4900
1910.303 A
- Issued
- Abate by
- Penalty
- Initial $3500.00 · Current $2125.00 Reduced
General-duty citation text
29 CFR 1910.303(a): The conductors and/or equipment required or permitted by this subpart were not approved: The W.S. Rockwell electric oven, s/n S966 (tagged 42 KW, 440 Volt, 3 phase, 60 cycles, 55 amperes per line), was manufactured on or about 07/03/1963 and then redesigned by W.S. Rockwell on or about 05/19/1964. The oven was installed at Davis Tool and Die sometime on or before 05/21/1993 and the oven wiring of heating elements has been modified from the manufacturers design. The oven has not been approved or inspected by an authority responsible for enforcing occupational safety provisions of the National Electrical Code since the installation at Davis Tool and Die located at 888 Bolger Ct, Fenton, MO, 63026.
Recent events (3)
- — F (S) $2125
- — C (S) $3500
- — Z (S) $3500
1910.303 B02
- Issued
- Abate by
- Penalty
- Initial $3500.00 · Current $2125.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: Location: Davis Tool & Die, 888 Bolger Ct, Fenton, MO, 63026 a) Middle of Bay 1: receptacle outlet box that energized pieces of equipment such as, but not limited to, Dell Programming Computer, monitor, and ventilation fan was not mounted as labeled, exposing employees to electrical hazards; b) South side of Bay 1: outdoor electrical outlet box partially affixed to equipment #331, W.S. Rockwell electric stress relief oven, s/n S966, and used for outdoor electrical supply was not mounted as labeled, exposing employees to electrical hazards; c) Northwest side of Bay 3: receptacle outlet box located next to electrical distribution sub panel P-5 was not mounted as labeled, exposing employees to electrical hazards.
Recent events (3)
- — F (O) $2125
- — C (S) $3500
- — Z (S) $3500
1910.303 G01
- Issued
- Abate by
- Penalty
- Initial $2100.00 · Current $2125.00
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: Location: Davis Tool and Die, 888 Bolger Ct., Fenton, Missouri 63026, bay 4, shipping and receiving department An electrical service panelboard located along the southwest wall had a sorting table located directly in front of it blocking safe access and working space.
Recent events (3)
- — F (O) $2125
- — C (S) $2100
- — Z (S) $2100
1910.332 B01
- Issued
- Abate by
- Penalty
- Initial $4900.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.332(b)(1): Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments: Location: Davis Tool and Die, 888 Bolger Ct., Fenton, Missouri 63026. On or about March 6, 2013 a maintenance worker performing repair activities on a 480 volt, three (3) phase Delta W.S. Rockwell electric oven, s/n S966, was electrocuted after contacting energized electrical components. Maintenance workers are not provided with safety related work practice training pertaining to their respective job assignments.
Recent events (3)
- — F (S) $0
- — C (S) $4900
- — Z (S) $4900
1910.333 A
- Issued
- Abate by
- Penalty
- Initial $4900.00 · Current $4500.00 Reduced
General-duty citation text
29 CFR 1910.333(a): Safety-related work practices were not employed to prevent electric shock or other injuries resulting from either direct or indirect electrical contacts, when work was performed near or on equipment or circuits which were or could be energized: Location: Davis Tool and Die, 888 Bolger Ct., Fenton, Missouri 63026. Safety related work practices had not been developed or implemented for the maintenance employees performing work on or near energized equipment. On or about March 6, 2013 a maintenance worker performing repair activities on a 480 volt, three (3) phase Delta W.S. Rockwell electric stress relief oven, s/n S966, was electrocuted after contacting energized electrical components.
Recent events (3)
- — F (S) $4500
- — C (S) $4900
- — Z (S) $4900
1910.333 A01
- Issued
- Abate by
- Penalty
- Initial $4900.00 · Current $2125.00 Reduced
General-duty citation text
29 CFR 1910.333(a)(1): Live parts to which an employee may be exposed were not deenergized before the employee worked on or was near to them: Location: Davis Tool and Die, 888 Bolger Ct., Fenton, Missouri 63026. On or about March 6, 2013 a maintenance worker performing repair activities on a 480 volt, three (3) phase Delta W.S. Rockwell electric oven, s/n S966, was electrocuted after contacting energized electrical components.
Recent events (3)
- — F (S) $2125
- — C (S) $4900
- — Z (S) $4900
1910.333 B02 IV B
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.333(b)(2)(iv)(B): A qualified person did not use test equipment to test the circuit elements and electrical parts of equipment to which employees would be exposed and did not verify that the circuit elements and equipment parts are deenergized: Location: The south part of bay 1 at Davis Tool and Die, 888 Bolger Ct., Fenton, Missouri 63026. On or about March 6, 2013 a maintenance worker performing repair activities on a 480 volt, three (3) phase Delta W.S. Rockwell electric oven, s/n S966, had no testing equipment with him to verify the parts were deenergized prior to working on the equipment. The worker was electrocuted after contacting energized electrical parts of the oven.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.333 C02
- Issued
- Abate by
- Penalty
- Initial $4900.00 · Current $2125.00 Reduced
General-duty citation text
29 CFR 1910.333(c)(2): The employer did not ensure that only qualified persons were working on energized circuits and that qualified persons were familiar with the proper use of special precautionary techniques, personal protective equipment, insulating and shielding materials, and insulated tools: Location: The south part of bay 1 at Davis Tool and Die, 888 Bolger Ct., Fenton, Missouri 63026. On or about March 6, 2013 a maintenance worker was performing repair activities on a 480 volt, three (3) phase Delta W.S. Rockwell electric oven, s/n S966. The worker was not familiar with the proper use of precautionary techniques while working on the oven, was not provided the proper personal protective equipment, was not provided with insulating and shielding materials, and was not provided insulated tools. The worker was electrocuted after contacting energized electrical components.
Recent events (3)
- — F (S) $2125
- — C (S) $4900
- — Z (S) $4900
1910.333 C08
- Issued
- Abate by
- Penalty
- Initial $4900.00 · Current $2125.00 Reduced
General-duty citation text
29 CFR 1910.333(c)(8): Conductive articles of jewelry and clothing (such a watch bands, bracelets, rings, key chains, necklaces, metalized aprons, cloth with conductive thread, or metal headgear) was worn where employees might contact exposed energized parts: Location: The south part of bay 1 at Davis Tool and Die, 888 Bolger Ct., Fenton, Missouri 63026. On or about March 6, 2013 a maintenance worker was performing repair activities on a 480 volt, three (3) phase Delta W.S. Rockwell electric oven, s/n S966, exposing energized electrical components. The worker was wearing metal framed eye protection and a belt with a metal buckle. The worker was electrocuted after contacting energized electrical components.
Recent events (3)
- — F (S) $2125
- — C (S) $4900
- — Z (S) $4900
1910.335 A01 I
- Issued
- Abate by
- Penalty
- Initial $4900.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.335(a)(1)(i): Employees working in areas where there are potential electrical hazards shall be provided with, and shall use, electrical protective equipment that is appropriate for the specific parts of the body to be protected and for the work to be performed: Location: The south part of bay 1 at Davis Tool and Die, 888 Bolger Ct., Fenton, Missouri 63026. On or about March 6, 2013 a maintenance worker was performing repair activities on a 480 volt, three (3) phase Delta W.S. Rockwell electric oven, s/n S966, exposing energized electrical components. The worker was not provided insulated gloves and was electrocuted after contacting energized electrical components.
Recent events (3)
- — F (S) $0
- — C (S) $4900
- — Z (S) $4900
1910.335 A02 I
- Issued
- Abate by
- Penalty
- Initial $4900.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.335(a)(2)(i): When working near exposed energized conductors or circuit parts, each employee did not use insulated tools or handling equipment when the tools or handling equipment might have made contact with such conductors or parts: Location: The south part of bay 1 at Davis Tool and Die, 888 Bolger Ct., Fenton, Missouri 63026. On or about March 6, 2013 a maintenance worker was performing repair activities on a 480 volt, three (3) phase Delta W.S. Rockwell electric oven, s/n S966, exposing energized electrical components. The worker was not provided insulated tools and was using an aluminum flashlight to visually inspect energized conductor rod and heating rack connections. The worker was electrocuted after contacting energized electrical components.
Recent events (3)
- — F (S) $0
- — C (S) $4900
- — Z (S) $4900
1910.212 A03 II
- Issued
- Abate by
- Penalty
- Initial $9800.00 · Current $2125.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): Location: Davis Tool and Die, 888 Bolger Ct, Fenton, MO 63026 At the time of the inspection, three CNC milling machines were operated without door interlocks exposing employees to point of operation hazards, including but not limited to: a) #606 Okuma Howa Millac 852V CNC Vertical Machine Center located in bay 1; b) #628 Hurco MDL VMX24 CNC Vertical Machine Center located in bay 3; c) #601 Okuma Vertical Machine CNT, MC-4VAE; d) At the time of the inspection, the spindle belonging to #601 Okuma Vertical Maching CNT, MC-4VAE was inadequately guarded by an adjustable polycarbonate shield. e) At the time of the inspection, #323 RK hydraulic 150 Ton Press, m/n 150T-E/H, in bay 3 had no guard. Poplar Bluff Tool & Die was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.212(a)(3)(ii), which was contained in OSHA inspection number 316235415, citation number 1, item number 1 and was affirmed as a final order on 03/22/2012, with respect to a workplace located at 266 Township Line Road, Poplar Bluff, MO, 63901.
Recent events (3)
- — F (S) $2125
- — C (R) $9800
- — Z (R) $9800
More inspections at DAVIS TOOL & DIE
FENTON, MO—2012-03-21 00:00:00
DAVIS TOOL & DIE
FENTON, MO—2008-06-04 00:00:00
DAVIS TOOL & DIE
View DAVIS TOOL & DIE's full OSHA safety record →
More inspections in this industry (NAICS 333513)
NERSTRAND, MN—2025-08-14
109683 - A - J DESIGN LLC LLC
BELLINGHAM, WA—2025-04-01
WA317985339 - ALL AMERICAN MARINE INC
BELLINGHAM, WA—2025-02-25
WA317984734 - ALL AMERICAN MARINE INC
PORTLAND, OR—2024-12-11
317738782 - NUCOR REBAR FABRICATION SEATTLE INC
SPOKANE, WA—2024-09-27 00:00:00
WA317982479 - H M S MACHINE TOOLS INC
More inspections in MO
CLINTON, MO—2026-07-14
TORCHYLO BUILDERS, LLC.
KANSAS CITY, MO—2026-07-09
NIAGARA BOTTLING
MONETT, MO—2026-07-09
MONETT METALS INC.
PARKVILLE, MO—2026-07-08
SKY-TECH ROOFING, LLC.
SPRINGFIELD, MO—2026-07-07
D & C CONSTRUCTION, LLC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338938335.