Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,871Inspections Most recent open 2026-07-30 Last loaded 2026-08-03

OSHA Inspection: FLY TIMBER CO.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of FLY TIMBER CO. in 164 SAWYER LOOP, WINONA, MS 38967 (NAICS 321113). OSHA activity number 338943962.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch FLY Timber CO. for free Get an email when a new federal OSHA severe-injury report for FLY Timber CO. is published. One employer, no account, unsubscribe in one click.
Establishment
FLY TIMBER CO.
Site address
164 SAWYER LOOP
City
WINONA
State
MS
ZIP
38967
Mailing
2178 HWY 7 NORTH, GRENADA, MS 38901
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321113
Employees
16
Ownership type
A

11 citations on file for this inspection.

1910.22 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 12, 2013
Abate by
May 1, 2013
Penalty
Initial $2,380 · Current $1,428 Reduced
29 CFR 1910.22(a)(1):   All places of employment, passageways, storerooms, and service rooms shall be kept clean and orderly and in a sanitary condition.   (a) Maintenance Shop and Main Saw - On or about March 06, 2013 employees were exposed to fire due to wood dust and chips accumulated on the ground up to a height of 15 inches.
Recent events (2)
  • · I (S) $1428
  • · Z (S) $2380

1910.147 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 12, 2013
Abate by
May 15, 2013
Penalty
Initial $2,975 · Current $1,785 Reduced
29 CFR 1910.147(c)(1):   Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative.  (a) Sawmill - On or about March 06, 2013 the employer did not provide an energy control program or lockout program for employees that perform maintenance on the main saw.
Recent events (2)
  • · I (S) $1785
  • · Z (S) $2975

1910.219 E01 I

Serious Gravity 5 2 instances 1 exposed
Issued
Apr 12, 2013
Abate by
May 15, 2013
Penalty
Initial $2,380 · Current $1,428 Reduced
29 CFR 1910.219(e)(1)(i):   Where both runs of horizontal belts are seven (7) feet or less from the floor level, the guard shall extend to at least fifteen (15) inches above the belt or to a standard height, except that where both runs of a horizontal belt are 42 inches or less from the floor, the belt shall be fully enclosed in accordance with paragraphs (m) and (o) of this section.  (a) Sawmill - On or about March 06, 2013 horizontal drive belts were not guarded at the following locations:  i. Main Chipper ii. Morbark Chipper
Recent events (2)
  • · I (S) $1428
  • · Z (S) $2380

1910.253 A03

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 12, 2013
Penalty
Initial $1,517 · Current $910 Reduced
29 CFR 1910.253(a)(3):   Apparatus. Only approved apparatus such as torches, regulators or pressure-reducing valves, acetylene generators, and manifolds shall be used.  (a) Maintenance Shop - On or about March 06, 2013 employee used a oxygen-acetylene cutting torch and the gages did not work on the regulators.
Recent events (2)
  • · I (S) $910.2
  • · Z (S) $1517

1910.265 C04 IV

Serious Gravity 1 2 instances 4 exposed
Issued
Apr 12, 2013
Abate by
May 8, 2013
Penalty
Initial $1,785 · Current $1,071 Reduced
29 CFR 1910.265(c)(4)(iv):   Elevated walks. All elevated walks, runways, or platforms, if 4 feet or more from the floor level, shall be provided with a standard railing except on loading or unloading sides of platforms. If height exceeds 6 feet, a standard toe board also shall be provided to prevent material from rolling or falling off.   (a) Sawmill - On or about March 06, 2013 elevated walkways 4 feet above the ground had missing and damaged guardrails in the following locations:   i. Debarker walkway.  ii. Edger/Tie Saw walkway.
Recent events (2)
  • · I (S) $1071
  • · Z (S) $1785

1910.265 C18 I

Serious Gravity 5 3 instances 2 exposed
Issued
Apr 12, 2013
Abate by
May 8, 2013
Penalty
Initial $2,975 · Current $1,785 Reduced
29 CFR 1910.265(c)(18)(i):   Standards. Construction, operation, and maintenance of conveyors shall be in accordance with American National Standard B20.1-1957, which is incorporated by reference as specified in Sec. 1910.6.   (a) Sawmill - On or about March 06, 2013 drive sprockets, chains and belts were not guarded at the following locations:   i. Dust Trough conveyor  ii. Main Saw Vibrator conveyor  iii. Debarker Bark Chain conveyor
Recent events (2)
  • · I (S) $1785
  • · Z (S) $2975

1910.305 B02 I

Serious Gravity 1 3 instances 1 exposed
Issued
Apr 12, 2013
Abate by
May 1, 2013
Penalty
Initial $1,785 · Current $1,071 Reduced
29 CFR 1910.305(b)(2)(i):   All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.   (a) Sawmill - On or about March 06, 2013 electrical junction boxes were missing covers in the following locations:   i. Main Saw  ii. Dust Trough
Recent events (2)
  • · I (S) $1071
  • · Z (S) $1785

1910.305 G02 II

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 12, 2013
Abate by
May 1, 2013
Penalty
Initial $1,785 · Current $1,071 Reduced
29 CFR 1910.305(g)(2)(ii):   Flexible cords may be used only in continuous lengths without splice or tap. Hard-service cord and junior hard-service cord No. 14 and larger may be repaired if spliced so that the splice retains the insulation, outer sheath properties, and usage characteristics of the cord being spliced.   (a) Tie Saw - On or about March 06, 2013 the flexible cord providing power to the control switch was spliced with wire nuts.
Recent events (2)
  • · I (S) $1071
  • · Z (S) $1785

1910.132 H01

Other-than-serious 2 instances 4 exposed
Issued
Apr 12, 2013
Abate by
May 1, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.132(h)(1):   Except as provided by paragraphs (h)(2) through (h)(6) of this section, the protective equipment, including personal protective equipment (PPE), used to comply with this part, shall be provided by the employer at no cost to employees.  (a) Sawmill - On or about March 06, 2013 the employer did not provide safety glasses and gloves at no cost to the employees.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.303 B01

Other-than-serious 1 instance 1 exposed
Issued
Apr 12, 2013
Abate by
May 1, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(1):   Examination. Electric equipment shall be free from recognized hazards that are likely to cause death or serious physical harm to employees.    (a) Sawmill - On or about March 06, 2013 the outside protective layer was damaged on the flexible wiring at the edger.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.305 G02 III

Other-than-serious 3 instances 2 exposed
Issued
Apr 12, 2013
Abate by
May 8, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii):   Flexible cords and cables shall be connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws.   (a) Sawmill - On or about March 06, 2013 strain relief was not connected to electrical junction boxes at the following locations:   i. Edger Control Panel  ii. Edger conveyor   iii Dust trough electrical box
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View FLY Timber CO.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338943962.