CANADIAN, TX —
OSHA Inspection: NOMAC DRILLING
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of NOMAC DRILLING in NOMAC RIG #135 18 MILES SE DIRECTION FROM CANADIAN, TX, CANADIAN, TX 79014 (NAICS 213111). OSHA activity number 338947153.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NOMAC DRILLING
- Site address
- NOMAC RIG #135 18 MILES SE DIRECTION FROM CANADIAN, TX
- City
- CANADIAN
- State
- TX
- ZIP
- 79014
- Mailing
- 501 S EASTERN, ELK CITY, OK 73644
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213111
- Employees
- 500
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.305 B02 I
- Issued
- Aug 1, 2013
- Abate by
- Aug 7, 2013
- Penalty
- Initial $3,740 · Current $2,992 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: On or about March 6, 2013, at the NOMAC Drilling Rig#135, the employer did not ensure the electrical outlet box on the Rig Manager's trailer had a cover. This condition exposed employees to an electrical shock hazard.
Recent events (2)
- — I (S) $2992
- — Z (S) $3740
1910.303 B02
- Issued
- Aug 1, 2013
- Abate by
- Aug 7, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: On or about March 06, 2013, at NOMAC Drilling Rig #135, the employer did not ensure the electrical breaker box was labeled on the Rig Manager's trailer. This condition exposed employees to an electrical shock hazard.
Recent events (1)
- — Z (S) $0
More inspections at Nomac Drilling
View Nomac Drilling's full OSHA safety record →
More inspections in this industry (NAICS 213111)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338947153.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.