Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: STS STEEL INC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of STS STEEL INC in 301 NOTT STREET, BLDG. 304, SCHENECTADY, NY 12305 (NAICS 332312). OSHA activity number 338948045.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch STS Steel INC — free Get an email when a new federal OSHA severe-injury report for STS Steel INC is published. One employer, no account, unsubscribe in one click.
Establishment
STS STEEL INC
Site address
301 NOTT STREET, BLDG. 304
City
SCHENECTADY
State
NY
ZIP
12305
Mailing
301 NOTT STREET, BLDG. 304, SCHENECTADY, NY 12305
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
55
Ownership type
A

5 citations on file for this inspection.

1910.107 E01

Serious Gravity 5 1 instance 42 exposed
Issued
May 8, 2013
Abate by
May 28, 2013
Penalty
Initial $2,100 · Current $1,470 Reduced
29 CFR 1910.107(e)(1): The storage of flammable or combustible liquids in connection with spraying operations did not conform to the requirements of 1910.106, where applicable:     (a) On or about March 12, 2013, in the main facility, methyl ethyl ketone used for cleaning the spray gun parts was stored on the floor in an used Carboline Zinc Filler metal container with a lid partially closed. The storage of this flammable liquid was not in compliance with 1910.106(e)(2)(iv)(d). An acceptable container to store this flammable liquid for cleaning gun parts would be a safety can, kept away from ignition sources such as the delivery truck.
Recent events (2)
  • — I (S) $1470
  • — Z (S) $2100

1910.1200 F05 I

Serious Gravity 5 1 instance 42 exposed
Issued
May 8, 2013
Abate by
May 28, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(5)(i): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein:     (a) On or about March 12, 2013, in the main facility, methyl ethyl ketone used for cleaning spray gun parts was stored on the floor in an used Carboline Zinc Filler metal container with a lid partially closed. The container didn't identify that methyl ethyl ketone was stored in this container.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 F05 II

Serious Gravity 5 1 instance 42 exposed
Issued
May 8, 2013
Abate by
May 28, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(5)(ii): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the appropriate hazard warnings:    (a) On or about March 12, 2013, in the main facility, methyl ethyl ketone used for cleaning spray gun parts was stored on the floor in an used Carboline Zinc Filler metal container with a lid partially closed. The container didn't identify the hazards of methyl ethyl ketone.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.107 E09

Serious Gravity 5 1 instance 42 exposed
Issued
May 8, 2013
Abate by
May 28, 2013
Penalty
Initial $2,100 · Current $0 Reduced
29 CFR 1910.107(e)(9): Whenever flammable or combustible liquids were transferred from one container to another, both containers were not effectively bonded and grounded to prevent discharge sparks of static electricity:    (a) On or about March 12, 2013, in the main facility, for the painter pouring Carbozinc 859 Part B into Carbozinc 859 Part A without bonding the containers.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2100

1910.134 D03 III B 2

Other-than-serious 1 instance 1 exposed
Issued
May 8, 2013
Abate by
Jun 12, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.134(d)(3)(iii)(B)(2): The employer did not implement a change schedule for respirators not equipped with an End of Service Life Indicator that would ensure cartridges were changed before the end of their service life:   (a) On or about March 13, 2013, in Bay B, for a a painter using a 3M full face respirator with organic vapor cartridges. The respiratory protection program currently in effect did not specify a change out schedule. The revised written respiratory protection program being developed referenced manufacturer recommendations but didn't specify those recommendaions. This manufacturer has developed a specific software program available on the web to allow the recommendations to be specific to each customer's use of the respirator.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View STS Steel INC's full OSHA safety record →