Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,195,903Inspections Most recent open 2026-08-18 Last loaded 2026-08-21

OSHA Inspection: COMBINED SYSTEMS INC - PENN ARMS DIVISION

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of COMBINED SYSTEMS INC - PENN ARMS DIVISION in 107 PINE STREET, PUNXSUTAWNEY, PA 15767 (NAICS 332994). OSHA activity number 338953557.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Combined Systems INC - Penn Arms Division for free Get an email when a new federal OSHA severe-injury report for Combined Systems INC - Penn Arms Division is published. One employer, no account, unsubscribe in one click.
Site address
107 PINE STREET
City
PUNXSUTAWNEY
State
PA
ZIP
15767
Mailing
107 PINE STREET, PUNXSUTAWNEY, PA 15767
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332994
Employees
260
Ownership type
Private (A)

8 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 12, 2013
Abate by
Oct 8, 2013
Penalty
Initial $5,000 · Current $3,750 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees        A.)  Combined Systems Inc., Penn Arms Division - On or about 3/12/13, employees were exposed to crush hazards from being ejected from powered industrial trucks that were not equipped with proper safety equipment.  Forklift (Hyster XLZ; Serial #B187V04679M) was not equipped with an operator restraint system (i.e. seat belt).  Employees operated the forklift for activities that included but were not limited to loading/unloading trucks
Recent events (2)
  • · I (S) $3750
  • · Z (S) $5000

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 12, 2013
Abate by
Oct 8, 2013
Penalty
Initial $4,000 · Current $3,000 Reduced
29 CFR 1910.212(a)(1):     One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:      A.)  Combined Systems Inc., Penn Arms Division; paint room; lathe Model #A, Catalog #670A - On or about 3/12/13, a lathe used for sanding did not have guarding over the rotating lathe head.
Recent events (2)
  • · I (S) $3000
  • · Z (S) $4000

1910.303 B02

Serious Gravity 5 1 instance 4 exposed
Issued
Sep 12, 2013
Abate by
Oct 8, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2):   Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:     A.)  Combined Systems, Inc., Penn Arms Division; paint room - On or about 3/12/13, the lathes start/stop switch was not designed and installed to prevent unintentional activation of the machine.  The start switch consisted of a lever that could be accidentally bumped/snagged.      B.)  Combined Systems, Inc., Penn Arms Division; paint room, production area, annealing area - On or about 3/12/13, general "household type" fans were being utilized in the working environment.  These fans were not designed for industrial environments.   C.) Combined Systems, Inc., Penn Arms Division; paint room - On or about 3/12/13, general  "household type" heaters were being utilized in the working environment.  These heaters were not designed for industrial environments.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.242 B

Serious Gravity 1 1 instance 3 exposed
Issued
Sep 12, 2013
Abate by
Oct 8, 2013
Penalty
Initial $3,000 · Current $2,250 Reduced
29 CFR 1910.242(b):     Compressed air used for cleaning. Compressed air shall not be used for cleaning purposes except where reduced to less than 30 p.s.i. and then only with effective chip guarding and personal protective equipment.      A.)  Combined Systems, Inc., Penn Arms Division;  - On or about 3/12/13, compressed air for blowing off parts and work areas was set at 70 p.s.i.  These air guns were located in areas including, but not limited to, the production area and the paint room.
Recent events (2)
  • · I (S) $2250
  • · Z (S) $3000

1910.252 B02 III

Other-than-serious 1 instance 4 exposed
Issued
Sep 12, 2013
Abate by
Oct 8, 2013
Penalty
Initial $3,000 · Current $0 Reduced
29 CFR 1910.252(b)(2)(iii):     Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields:      A.)  Combined Tactical Systems, Inc., Penn Arms Division; production area - On or about 3/12/13, welding operations were taking place without any protection for the nearby employees from welder's flash.
Recent events (2)
  • · I (O) $0
  • · Z (S) $3000

1910.303 B06

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 12, 2013
Abate by
Oct 8, 2013
Penalty
Initial $4,000 · Current $3,000 Reduced
29 CFR 1910.303(b)(6):     Deteriorating agents.  Conductors or equipment shall not be located in damp or wet locations; where exposed to gases, fumes, vapors, liquids, or other agents that had a deteriorating effect on the conductors or equipment; or where exposed to excessive temperatures.      A.)  Combined Systems Inc., Penn Arms Division; assembly area - On or about 3/12/13, the roof  was leaking rain water.  The water was leaking onto a light in the area.
Recent events (2)
  • · I (S) $3000
  • · Z (S) $4000

1910.305 G01 IV A

Other-than-serious 1 instance 2 exposed
Issued
Sep 12, 2013
Abate by
Oct 8, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A):   Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:    A.)  Combined Systems Inc., Penn Arms Division; heat treating area - On or about 3/12/13, an extension cord was daisy chained to a multi-plug cord to power a fluorescent lamp.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.145 C02 I

Other-than-serious 1 instance 2 exposed
Issued
Sep 12, 2013
Abate by
Oct 8, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.145(c)(2)(i): Caution signs were not used to warn against potential hazards or to caution against unsafe practices:  A.) Combined Systems, Inc., Penn Arms Division - On or about 3/12/13, caution signs were not posted at key access ways and entranceways to warn personnel when guns were being test fired.  The access ways and entranceways included but were not limited to heat/treat annealing garage door and front door.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0