SYRACUSE, NY —
OSHA Inspection: EDWARD SCHALK & SON, INC.
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of EDWARD SCHALK & SON, INC. in 301 PROSPECT AVENUE, SYRACUSE, NY 13203 (NAICS 238130). OSHA activity number 338957723.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EDWARD SCHALK & SON, INC.
- Site address
- 301 PROSPECT AVENUE
- City
- SYRACUSE
- State
- NY
- ZIP
- 13203
- Mailing
- 6801 MYERS ROAD, EAST SYRACUSE, NY 13057
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 8
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.451 D03 VI
- Issued
- Apr 19, 2013
- Penalty
- Initial $1,600 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(d)(3)(vi): Outrigger beams which are not stabilized by bolts or other direct connections to the floor or roof deck were not secured by tiebacks: a) On or about 3/13/2013, At the roof elevation: A two point suspension scaffold was used with tie backs that had slack in the cables.
Recent events (3)
- — J (S) $0
- — C (S) $1600
- — Z (S) $1600
1926.451 D12 VI
- Issued
- Apr 19, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(d)(12)(vi): When U-bolt clips are used, the U-bolt shall be placed over the dead end of the rope, and the saddle shall be placed over the live end of the rope. a) On or about 3/13/2013, At the roof elevation: A two point suspension scaffold was used with cable tie backs that utilized U-bolt clips. The U-bolt portion of the clips were placed over the live end of the cable.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1926.451 G03 I
- Issued
- Apr 19, 2013
- Penalty
- Initial $2,000 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(g)(3)(i): vertical lifelines were not fastened to a fixed safe point of anchorage, independent of the scaffold, and protected from sharp edges and abrasion. a) On or about 3/13/2013, At the roof elevation: A two point suspension scaffold was used with independent lifelines that were not protected from the metal roof edge.
Recent events (3)
- — J (S) $0
- — C (S) $2000
- — Z (S) $2000
More inspections at Edward Schalk & SON, INC.
View Edward Schalk & SON, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338957723.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.