Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: COUNTRYSIDE CONSTRUCTION

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of COUNTRYSIDE CONSTRUCTION in 5803 BLUFFLEDGE ROAD, STURGEON BAY, WI 54235 (NAICS 236115). OSHA activity number 338958507.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Countryside Construction — free Get an email when a new federal OSHA severe-injury report for Countryside Construction is published. One employer, no account, unsubscribe in one click.
Site address
5803 BLUFFLEDGE ROAD
City
STURGEON BAY
State
WI
ZIP
54235
Mailing
4737 PINE GROVE ROAD, DENMARK, WI 54208
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236115
Employees
4
Ownership type
A

10 citations on file for this inspection.

1926.451 B02

Serious Gravity 1 1 instance 4 exposed
Issued
Apr 3, 2013
Abate by
May 22, 2013
Penalty
Initial $1,200 · Current $700 Reduced
29 CFR 1926.451(b)(2):  Except as provided in paragraphs (b)(2)(i) and (b)(2)(ii) of this section, each scaffold platform and/or walkway was not at least 18 inches (46 cm) wide:    a) On 03-14-13, employees who were installing soffit and fascia were working from scaffold planks that were less than twelve (12) inches wide.    ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $700
  • — Z (S) $1200

1926.451 B05 I

Serious Gravity 1 2 instances 4 exposed
Issued
Apr 3, 2013
Abate by
May 20, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.451(b)(5)(i):  The end of a platform 10 feet or less in length extended over its support more than 12 inches and the platform was not designed and installed so that the cantilevered portion of the platform is able to support employees and/or materials without tipping, or has guardrails which block employee access to the cantilevered end:    a)  On 03-14-13, employees who were installing soffit and fascia along the front side of a home were working from carpenter's wall bracket scaffold on a nine (9) ft. L wood plank extended more than twelve (12) inches over an end bracket support.    b)  On 03-14-13, employees who were installing soffit and fascia along the front side of a home were working from carpenter's wall bracket scaffold on a ten (10) ft. L wood plank extended more than twenty-five (25) inches over and past an end plank support.      ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 F04

Serious Gravity 1 1 instance 4 exposed
Issued
Apr 3, 2013
Abate by
May 20, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.451(f)(4):  Part(s) of a scaffold that were damaged or weakened, such that the scaffold's strength was less than that required by paragraph (a) of this section, were not immediately repaired, replaced, braced to meet those provisions, nor removed from service until repaired:      A) On 03-14-13, employees who were working from Carpenter's wall bracket scaffold were working from two ten (10) ft. L damaged wood planks.      ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.454 B02

Serious Gravity 1 1 instance 4 exposed
Issued
Apr 3, 2013
Abate by
May 20, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.454(b)(2):  The employer did not have each employee trained by a competent person in the correct procedures for erecting, disassembling, moving, operating, repairing, inspecting, and maintaining the type of scaffold in question:      a) Employees who were not trained did not associate fall hazard with erecting Carpenter's wall bracket scaffold without bolts to attach to the wall, without attaching all diagonal bracing to the wall, without fully decking the walking/working surface, with using damaged equipment, and with using the rungs on six foot step ladders as plank supports.    ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1053 B07

Serious Gravity 1 1 instance 4 exposed
Issued
Apr 3, 2013
Abate by
May 20, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(7):  Ladders were used on slippery surfaces:      a) On 03-14-13, employees who were utilizing a six (6) ft. Werner step ladder rung to support a scaffold plank had positioned the ladder on an icy surface with the ladder's left front foot placed on the metal surface of the tube portion of a stored scaffold upright frame.      ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 C02 V

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 3, 2013
Abate by
May 22, 2013
Penalty
Initial $1,600 · Current $700 Reduced
29 CFR 1926.451(c)(2)(v):  The employer used forklifts  to support scaffold platforms without ensuring that the entire platform was attached to the fork and that the forklift was not moved horizontally while the platform was occupied:    a) On 03-14-13, an employee was working at a height greater than 7.5 feet above compacted surface from an elevated platform on a Sky Trak 4270L Telehandler forklift without securing the platform to the forks.      ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $700
  • — Z (S) $1600

1926.1053 B09

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 3, 2013
Abate by
May 22, 2013
Penalty
Initial $1,200 · Current $700 Reduced
29 CFR 1926.1053(b)(9):  The area around the top and/or bottom of (a) ladder(s) was not kept clear:      a) On 03-14-13, an employee was utilizing a twenty-four (24) ft. wood extension ladder with the end of side rails of a ladder lying on the ground within one foot of the extension ladder's base.    ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $700
  • — Z (S) $1200

1926.1053 B16

Serious Gravity 1 4 instances 4 exposed
Issued
Apr 3, 2013
Abate by
May 20, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(16):  Portable ladder(s) with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components were not either immediately marked in a manner that readily identifies them as defective or tagged with "Do Not Use" or similar language and withdrawn from service until repairs:    a)  On 03-14-13, employees were utilizing a damaged six (6) ft. Werner portable step ladder as a scaffold support for a scaffold plank placed on the fifth rung.    b)  On 03-14-13, an employee who was installing soffit/fascia was utilizing a damaged twenty-two (24) ft. wood extension ladder.    c)  On 03-14-13, employees had available for use one damaged thirty-two (32) ft. wood extension ladder.    d)  On 03-14-13, employees had available for use one damaged eight (8) ft. Werner portable step ladder.    ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1060 A

Serious Gravity 1 1 instance 4 exposed
Issued
Apr 3, 2013
Abate by
May 20, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.1060(a):  The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards:      a) Employees, who were not trained in ladder safety, did not associate fall from elevation hazards with utilizing step ladders improperly as part of scaffold, positioned on slippery surfaces, and with damaged parts; employees did not associate fall hazards with utilizing damaged extension ladders and tripping hazards with equipment stored at the base of the ladder.    ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.403 B02

Other-than-serious 1 instance 3 exposed
Issued
Apr 3, 2013
Abate by
May 20, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.403(b)(2):  Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification:      a) On 03-14-13, employees were utilizing a metal handy box positioned on icy ground as an outdoor power tap.      ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Countryside Construction's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338958507.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.