MAXWELL, TX —
OSHA Inspection: MAXWELL MANUFACTURING, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of MAXWELL MANUFACTURING, INC. in 55 2ND STREET, MAXWELL, TX 78656 (NAICS 326199). OSHA activity number 338959729.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MAXWELL MANUFACTURING, INC.
- Site address
- 55 2ND STREET
- City
- MAXWELL
- State
- TX
- ZIP
- 78656
- Mailing
- 55 2ND STREET, MAXWELL, TX 78656
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 36
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.242 B
- Issued
- Mar 22, 2013
- Abate by
- Apr 1, 2013
- Penalty
- Initial $2,100 · Current $1,260 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: On or about March 12, 2013, employees used compressed air in excess of 30 psig for blowing water out of molds and cleaning hopper loaders and hoses to remove regrind dust, exposing employees to the hazard of being struck by debris. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure air nozzles used for cleaning are reduced to at least 30 psig.
Recent events (2)
- — I (S) $1260
- — Z (S) $2100
1910.303 B02
- Issued
- Mar 22, 2013
- Abate by
- Apr 1, 2013
- Penalty
- Initial $2,100 · Current $1,260 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: On or about March 12, 2013, equipment was not used according to its labeled use, exposing employees to shock and burn hazards. a: A surge protector made for small appliances was used in the material mixing area to power the vacuum loader, scale, a fan, and extension cord not powering anything. b: A surge protector made for small appliances was used in the material mixing area to power a scale and the surge protector in instance a. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that electrical equipment and wiring is used as listed and labeled.
Recent events (2)
- — I (S) $1260
- — Z (S) $2100
1910.305 B02 I
- Issued
- Mar 22, 2013
- Abate by
- Apr 1, 2013
- Penalty
- Initial $3,500 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: On or about July 23, 2012, the receptacle box powering the loader on Press 2 was missing its faceplate, exposing employees to burn and shock hazards. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that all pull boxes, junction boxes, and fittings are equipped with the appropriate covers and are installed so that there are no gaps or openings.
Recent events (2)
- — I (S) $2100
- — Z (S) $3500
1910.305 B01 II
- Issued
- Mar 22, 2013
- Abate by
- Apr 1, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: On or about March 12, 2013, knockouts were missing from receptacle boxes on Presses 2 and 10, exposing employees to burn and shock hazards. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that unused openings in cabinets, boxes, and fittings are effectively closed.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G01 IV A
- Issued
- Mar 22, 2013
- Abate by
- Apr 1, 2013
- Penalty
- Initial $2,100 · Current $1,260 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: On or about March 12, 2013, flexible cords were used as permanent wiring, exposing employees to shock and burn hazards. a: An extension cord hardwired into a receptacle box that powered the loader on Press 2 was used as permanent wiring. b: An extension cord in the material mixing area was used permanently to power a surge protector. c: An extension cord permanently connected to the surge protector in the material mixing area was spliced into a light switch which, in turn, was spliced into the vacuum loader. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that flexible cords are not affixed to building surfaces and used as permanent wiring.
Recent events (2)
- — I (S) $1260
- — Z (S) $2100
1910.305 G01 IV D
- Issued
- Mar 22, 2013
- Abate by
- Apr 1, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(D): Flexible cords and cables were used where attached to building surfaces: a: An extension cord in the material mixing area was affixed to the structure and used permanently to power a surge protector. b: The surge protector powering a scale and an additional surge protector in the material mixing area was affixed to the structure of the mixer. c: The surge protector powering the vacuum loader, scale, fan, and extension cord in the material mixing area was affixed to the structure of the mixer. d: An extension cord permanently connected to the surge protector in the material mixing area was affixed to the structure of the mixer and spliced into a light switch controlling the vacuum loader. On or about March 12, 2013, flexible cords were affixed to the structure, exposing employees to shock and burn hazards. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that flexible cords are not affixed to building surfaces and used as permanent wiring.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G02 II
- Issued
- Mar 22, 2013
- Abate by
- Apr 1, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap: On or about March 12, 2013, flexible cords were not used in continuous lengths in the facility, exposing employees to shock and burn hazards. a: An extension cord was hardwired into a receptacle box that powered the loader on Press 2. b: An extension cord in the material mixing area was spliced into a light switch which, in turn, was spliced into the vacuum loader. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that flexible cords are used in continuous lengths.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Maxwell Manufacturing, INC.
View Maxwell Manufacturing, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 326199)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338959729.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.