Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PLANO SUPER BOWL, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of PLANO SUPER BOWL, INC. in 2521 K AVENUE, PLANO, TX 75074 (NAICS 713950). OSHA activity number 338966831.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Plano Super Bowl, INC. — free Get an email when a new federal OSHA severe-injury report for Plano Super Bowl, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2521 K AVENUE
City
PLANO
State
TX
ZIP
75074
Mailing
2521 K AVENUE, PLANO, TX 75074
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
713950
Employees
36
Ownership type
A

8 citations on file for this inspection.

1910.23 C03

Serious Gravity 10 48 instances 5 exposed
Issued
Sep 11, 2013
Abate by
Jan 24, 2014
Penalty
Initial $4,900 · Current $1,000 Reduced
29 CFR 1910.23(c)(3): Regardless of height, open-sided floors, walkways, platforms, or runways above or adjacent to dangerous equipment, pickling or galvanizing tanks, degreasing units, and similar hazards were not guarded with a standard railing and toe board:    The employer did not provide a guardrail system, or equivalent, for employees, who walked and/or worked on top of the automatic pinsetters when servicing, maintaining, repairing and/or unjamming the machines.   This violation occurred on March 20, 2013, and at times prior thereto, the employees, who were clearing jams, servicing, repairing motor, were exposed to the hazard of falling into pinsetter machines.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $4900

1910.24 B

Serious Gravity 5 24 instances 5 exposed
Issued
Sep 11, 2013
Abate by
Jan 24, 2014
Penalty
Initial $2,800 · Current $800 Reduced
29 CFR 1910.24(b): Fixed stairs were not provided for access from one structure level to another where operations necessitated regular travel between levels, and for access to operating platforms at any equipment which requires attention routinely during operations:    The employer did not provide fixed stairs for employees, who climbed onto the automatic pinsetters when servicing, maintaining, repairing, and unjamming the machines.  This violation occurred on March 20, 2013, and at times prior thereto; when the employees, who were exposed to the hazard of falling more than 24-inches while servicing, repairing motor, unjamming the pinsetters onto which they had climbed without the benefit of fixed stairs or equivalent means of safe access.
Recent events (2)
  • — I (S) $800
  • — Z (S) $2800

1910.147 C01

Serious Gravity 10 1 instance 5 exposed
Issued
Sep 11, 2013
Abate by
Jan 24, 2014
Penalty
Initial $4,900 · Current $2,000 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:    This violation occurred on March 20, 2013, and at times prior thereto; the employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing, maintenance, repairing and/or unjamming the pinsetters where the unexpected energizing, startup or release of stored energy could occur and cause injury.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $4900

1910.212 A01

Serious Gravity 10 96 instances 5 exposed
Issued
Sep 11, 2013
Abate by
Aug 16, 2014
Penalty
Initial $4,900 · Current $4,200 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    The employer did not protect employees, who serviced, maintained, repaired, and/or unjammed automatic pinsetter machines, from the hazards of being caught-in and/or caught-between moving parts of the machines. This violation occurred on March 20, 2013, and at times prior thereto; when employees were exposed to being caught-in or caught-between:       a.     The unguarded pinch points created by moving levers, cams, shafts, arms, cracks, rods and rake boards and springs of the pinsetter machines #1 through #48.    b.     The Elevator wheels of the pinsetter machines #1 through #48, were not guarded to prevent employees from reaching into the machines.
Recent events (2)
  • — I (S) $4200
  • — Z (S) $4900

1910.219 D01

Serious Gravity 10 528 instances 5 exposed
Issued
Sep 11, 2013
Abate by
Aug 16, 2014
Penalty
Initial $4,900 · Current $0 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):    The employer did not protect employees from on-going nip points created by rotating pulleys. This violation occurred on March 20, 2013, and at times prior thereto; when employees, who serviced, maintained, repaired and/or unjammed pinsetter machines in lanes #1 through #48 were exposed to the following unguarded pulleys:      a.     Three (3) pit conveyor pulleys.  b.     Two (2) ball wheel pulleys.  c.     One (1) elevator belt pulleys.  d.     One (1) elevator cross pulleys.  e.     One (1) pin wheel belt pulley.  f.      One (1) cross conveyor belt pulley.  g.     Two (2) motor pulleys.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4900

1910.219 E01 I

Serious Gravity 10 144 instances 5 exposed
Issued
Sep 11, 2013
Abate by
Aug 16, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(1)(i): Where both runs of horizontal belts were seven (7) feet or less from the floor level, the guard shall extend to at least fifteen (15) inches above the belt or to a standard height, except that Where both runs of a horizontal belt were 42 inches or less from the floor, the belt was not fully enclosed in accordance with paragraphs (m) and (o) of this 1910.219, and where both runs of horizontal belts were seven (7) feet or less from the floor level, a guard that extended at least fifteen (15) inches above the belt or to a standard height was not provided:      The employer did not protect employees from contacting horizontal belts with guards which are fully enclosed, or extend at least fifteen (15) inches above the belt or to a standard height. This violation occurred on March 20, 2013, and at times prior thereto; when employees were exposed to the following drive belts on each of the forty-eight (48) pinsetter machines:      a.       Unguarded horizontal, pit conveyor belt.  b.       Unguarded horizontal, cross conveyor drive belt.  c.       Unguarded horizontal, long turret drive belt.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 E03 I

Serious Gravity 10 144 instances 5 exposed
Issued
Sep 11, 2013
Abate by
Aug 16, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(3)(i):  Vertical or inclined belt(s) were not enclosed by guard(s) confirming to the requirements specified at 29 CFR 1910.219(m) and (o):    The employer did not protect employees from contacting vertical and inclined belts. This violation was occurred on March 20, 2013, and at times prior thereto; when employees, who serviced, repaired and/or unjammed pinsetter machines were exposed to the following drive belts on each of the forty-eight (48) pinsetter machines:      a.      One (1) unguarded ball wheel belt.  b.      One (1) unguarded pin wheel belt.  c.      One (1) unguarded elevator belt at the motor.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G02 III

Other-than-serious 3 instances 5 exposed
Issued
Sep 11, 2013
Abate by
Jan 24, 2014
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:     The employer did not ensure that flexible cords were connected to devices and fittings so that tension is not transmitted to joints or terminal screws. This was occurred on March 20, 2013, when employees, who serviced, maintained, repaired, and/or unjammed pinsetter machines #1, #4, #6, were exposed to an electrical hazard from the outer insulation of the power cords to the control boxes separating from the attachment plug cord clamp exposing the conductors to pull.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2800

View Plano Super Bowl, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338966831.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.