OCOEE, FL ·
OSHA Inspection: F/X DESIGN GROUP, LLC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of F/X DESIGN GROUP, LLC in 922 N. LAKEWOOD AVENUE, OCOEE, FL 34761 (NAICS 512290). OSHA activity number 338979529.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- F/X DESIGN GROUP, LLC
- Site address
- 922 N. LAKEWOOD AVENUE
- City
- OCOEE
- State
- FL
- ZIP
- 34761
- Mailing
- 922 N. LAKEWOOD AVENUE, OCOEE, FL 34761
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 512290
- Employees
- 43
- Ownership type
- Private (A)
Citations
8 citations on file for this inspection.
1910.212 A03 II
- Issued
- May 16, 2013
- Abate by
- May 22, 2013
- Penalty
- Initial $3,500 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a. Wood shop - employees were exposed to amputation hazards, in that, the table saws used to cut plywood and particle board were not guarded by an automatic adjusting hood. Violation observed on or about 03/27/13.
Recent events (2)
- · I (S) $2100
- · Z (S) $3500
1910.213 C01
- Issued
- May 16, 2013
- Abate by
- May 22, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(c)(1): Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: a. Wood department - employees were exposed to amputation hazards, in that, the table saw used to cut dimensional lumber was not guarded by an automatic adjusting hood. Violation observed on or about 03/27/13.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.107 B05 I
- Issued
- May 16, 2013
- Abate by
- May 22, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(b)(5)(i): Visible gauges or audible alarms or pressure activated devices were not installed to indicate or insure that the required air velocity is maintained: a. Spray booth - the JBI Manometer mounted on the side of the spray booth was not operational. Violation observed on or about 03/27/13.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.134 E01
- Issued
- May 16, 2013
- Abate by
- May 22, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a. Spray Painting - employees wearing SAS half-face elastomeric respirators were not medically qualified to wear the respirator. Violation observed on or about 03/27/13.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.134 C02 I
- Issued
- May 16, 2013
- Abate by
- May 22, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: a. At the site - employees wearing respirators voluntarily were not provided with the information contained in Appendix D. Violation observed on or about 03/27/13.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.242 B
- Issued
- May 16, 2013
- Abate by
- May 22, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a. Wood shop area - employees were exposed to a struck-by hazard, in that, the air pressure nozzle was at 110 p.s.i. Violation observed on or about 03/27/13. b. CNC machine area - employees were exposed to a struck-by hazard, in that, the air pressure nozzle was at 80 p.s.i. Violation observed on or about 03/27/13.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.1200 E01
- Issued
- May 16, 2013
- Abate by
- May 22, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a. At the site - the employer did not develop a written hazard communication program. Violation observed on or about 03/27/13.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.1200 F05
- Issued
- May 16, 2013
- Abate by
- May 22, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(5): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged, or marked with the identity and appropriate hazard warnings regarding the chemicals contained therein: a. Work shop - employees were exposed to chemical hazards, in that, a container of wood glue and container of degreaser were not labeled. Violation observed on or about 03/27/13.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 512290)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 338979529.