WILMINGTON, NC —
OSHA Inspection: YILDIZ ENTEGRE USA, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of YILDIZ ENTEGRE USA, INC. in 1715 WOODBINE ST,, WILMINGTON, NC 28403 (NAICS 321999). OSHA activity number 338979651.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- YILDIZ ENTEGRE USA, INC.
- Site address
- 1715 WOODBINE ST,
- City
- WILMINGTON
- State
- NC
- ZIP
- 28403
- Mailing
- 1715 WOODBINE ST,, WILMINGTON, NC 28403
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321999
- Employees
- 7
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.303 B01 II
- Issued
- May 17, 2013
- Abate by
- May 17, 2013
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.303(b)(1)(ii): Electrical equipment was not free from a recognized hazard that was likely to cause death or serious physical harm to employees, in that the employer did not provide conduit with the mechanical strength and durability designed to enclose and protect circuit conductors wiring as required by NEC-2008, Article 300.37. On or about 26 March 2013, a 110v flexible cord was laying on the ground and was connected to a 110v receptacle outlet. The cord was dangling within inches of water and over several obstructions.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1910.305 J02 V
- Issued
- May 17, 2013
- Abate by
- Jun 20, 2013
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1910.305(j)(2)(v): A receptacle installed outdoors in a location protected from the weather or in other damp locations did not have an enclosure for the receptacle that was weatherproof when the receptacle was covered. Myers Street Chip Corral, Wilmington, NC Shipping Terminal: Employer failed to use an approved weatherproof receptacle for outdoor use. Employees were exposed to shock hazards.
Recent events (2)
- — I (S) $600
- — Z (S) $1200
1917.11 A
- Issued
- May 17, 2013
- Abate by
- May 17, 2013
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1917.11(a): Active work areas were not kept free of equipment, materials, debris, protruding nails, and other sharp objects not necessary for the work in progress. Myers Street Chip Corral, Wilmington, NC Shipping terminal: The Peterson 5000 loader catwalk passageway leading to the operator cab was obstructed by a 200 lb motor. Employees were exposed to tripping hazards.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1917.48 I01
- Issued
- May 17, 2013
- Abate by
- Jul 20, 2013
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1917.48(i)(1): Conveyors were not stopped and their power sources were not locked out and tagged out during maintenance, repair, and servicing, except where the power was necessary for testing. Myers Street Chip Corral, Wilmington, NC Shipping Terminal: The employer did not establish a lockout tagout program. In addition, locking devices were not utilized and energy control procedures were not developed for employees to follow while performing maintenance, repair and servicing the rollers on the conveyor system.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1917.151 B07
- Issued
- May 17, 2013
- Abate by
- Jul 20, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1917.151(b)(7): The power supply to machines was not turned off, locked out and tagged out during repair, adjustment, or servicing. On or about March 26, 2013, employees performing maintenance work on the conveyor system did not affix a lockout device to an energy isolating device.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1917.151 B08
- Issued
- May 17, 2013
- Abate by
- Jul 20, 2013
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1917.151(b)(8): Machines were not maintained in a safe working condition. a) Myers Street Chip Corral, Wilmington, NC Shipping Terminal: On or about March 26, 2013, employer did not maintain the Peterson 5000 loader in a safe conditio. Employees were exposed to fall hazards greater than 10 feet due to inproper access to the operator cab. b) Myers Street Chip Corral, Wilmington, NC Shipping Terminal: On or about March 26, 2013, employer did not maintain the Peterson 5900 loader in a safe condition. Employees were exposed to combustible fire hazards due to diesel leaking from a defective fuel tank onto the ground.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1917.151 H02
- Issued
- May 17, 2013
- Abate by
- Jun 20, 2013
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1917.151(h)(2): Belt, rope, and chain drives were not guarded to prevent employees from coming into contact with moving parts. a) Myers Street Chip Corral, Wilmington, NC Shipping Terminal: On or before 26 Mar 2013, employees were exposed to an amputation hazard. Belt guards were not present while operating the Peterson 5000 loader. b) Myers Street Chip Corral, Wilmington, NC Shipping Terminal: On or before 26 Mar 2013, employees were exposed to an amputation hazard. Chain guards were not present while operating the Peterson 5000 loader. c) Myers Street Chip corral, Wilmington, NC Shipping Terminal. On or about 26 Mar 2013, employees were exposed to an amputation hazard. Chain guards were not present while operating the Peterson 5900 chipper.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1910.305 G01 IV A
- Issued
- May 17, 2013
- Abate by
- May 17, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure. Flexible cords and cables were used as a substitute for the fixed wiring of a structure: On or about 26 March, 2013, an electrical power strip was being used in lieu of fixed wiring to provide electrical power to a microwave.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Yildiz Entegre USA, INC.
View Yildiz Entegre USA, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 321999)
More inspections in NC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338979651.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.