Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FRANCISCO PEREZ

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of FRANCISCO PEREZ in 4411 N. MELVINA AVE., CHICAGO, IL 60630 (NAICS 238160). OSHA activity number 338984271.

Watch Francisco Perez — free Get an email when a new federal OSHA severe-injury report for Francisco Perez is published. One employer, no account, unsubscribe in one click.
Establishment
FRANCISCO PEREZ
Site address
4411 N. MELVINA AVE.
City
CHICAGO
State
IL
ZIP
60630
Mailing
119 AMARILLO DR., CARPENTERSVILLE, IL 60110
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
7
Ownership type
A

10 citations on file for this inspection.

1903.19 C01

Other-than-serious 1 instance 1 exposed
Issued
Dec 3, 2013
Abate by
Jan 7, 2014
Penalty
Initial $400 · Current $400
29 CFR 1903.19(c)(1):  The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated:    Francisco Perez, dba Francisco Roofing, failed to certify to OSHA within 10 calendar days after the abatement date that each of the following cited violations had been corrected:    Citation Number                     Item Number                           Abatement Date  01                                            01                                            08/16/2013 01                                            02                                            08/16/2013 01                                            03a                                          08/16/2013 01                                            03b                                          08/16/2013 01                                            04                                            09/13/2013 01                                            05a                                          08/16/2013 01                                            05b                                          08/16/2013 01                                            05c                                          09/13/2013 02                                            01                                            08/16/2013     In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (O) $400

1926.300 B02

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 12, 2013
Abate by
Aug 16, 2013
Penalty
Initial $1,600 · Current $1,600
29 CFR 1926.300(b)(2): Moving part(s) of equipment exposed to contact by employees or which otherwise created a hazard, were not guarded:  a)  The belt and pulley drive on a Briggs & Stratton material hoist engine were not guarded in order to prevent employees from the accidental contact with the moving parts.   In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (S) $1600

1926.416 E01

Serious Gravity 5 1 instance 4 exposed
Issued
Aug 12, 2013
Abate by
Aug 16, 2013
Penalty
Initial $1,600 · Current $1,600
29 CFR 1926.416(e)(1):  Worn or frayed electric cords or cables were used:    a) The insulation on the flexible cord on the Ridgid Circular Saw used by employee to cut construction lumber onsite was worn at the strain relief as evidenced by the exposed insulated conductors.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (S) $1600

1926.452 M01

Serious Gravity 5 1 instance 4 exposed
Issued
Aug 12, 2013
Abate by
Aug 16, 2013
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.452(m)(1): Crawling boards did not extend from the roof peak to the eaves when used in connection with roof construction, repair, or maintenance:  a)  Employees engaged in roofing activity were working from the crawling boards that did not extend from the roof peak to the roof eave.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (S) $2000

1926.452 M02

Serious Gravity 5 1 instance 4 exposed
Issued
Aug 12, 2013
Abate by
Aug 16, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.452(m)(2): Crawling boards were not secured to the roof by ridge hooks or by means that meet equivalent criteria (e.g., strength and durability):  a)  Employees engaged in roofing activity were working from the crawling boards that were not secured to the roof by the ridge hooks.   In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (S) $0

1926.503 A01

Serious Gravity 5 1 instance 4 exposed
Issued
Aug 12, 2013
Abate by
Sep 13, 2013
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.503(a)(1):  The employer did not provide a training program for each employee who might be exposed to fall hazards:     a)  Employer did not provide training to each employee in order to recognize hazards associated with working at an elevation and to understand procedures to control or minimize those hazards.     In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (S) $2000

1926.1053 B01

Serious Gravity 5 1 instance 4 exposed
Issued
Aug 12, 2013
Abate by
Aug 16, 2013
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:     a)  Ladders used by employees to gain access to the working surface did not have its side rails extended at least 3 feet above the surface.      In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (S) $2000

1926.1053 B04

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 12, 2013
Abate by
Aug 16, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed:    a)  The extension ladder was used by three employees simultaneously, to access and/or egress the roof.      In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (S) $0

1926.1060 A

Serious Gravity 5 1 instance 4 exposed
Issued
Aug 12, 2013
Abate by
Sep 13, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.1060(a):  The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards:     a) Employer did not provide training program to each employee in order to recognize hazards associated with working from ladders, and to understand procedures to control or minimize those hazards.      In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (S) $0

1926.501 B11

Willful Gravity 10 1 instance 4 exposed
Issued
Aug 12, 2013
Abate by
Aug 16, 2013
Penalty
Initial $14,000 · Current $14,000
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems:  a)  Employees engaged in roofing activity were not protected from fall hazards while working at an elevation of approximately 26 feet above the ground.     In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (W) $14000