LODI, NJ ·
OSHA Inspection: VIVINT SOLAR DEVELOPER LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of VIVINT SOLAR DEVELOPER LLC in 570 MAIN STREET, LODI, NJ 07644 (NAICS 221114). OSHA activity number 338988462.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- VIVINT SOLAR DEVELOPER LLC
- Site address
- 570 MAIN STREET
- City
- LODI
- State
- NJ
- ZIP
- 07644
- Mailing
- 16 CHAPIN RD, PINE BROOK, NJ 07058
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 221114
- Employees
- 1000
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1926.501 B01
- Issued
- May 2, 2013
- Penalty
- Initial $7,000 · Current $3,500 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): "Unprotected sides and edges." Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. Location: On the roof of the house; a) Employee was exposed to a fall of approximately 20 ft while working on the roof without fall protection; on or about 03/29/13.
Recent events (2)
- · I (S) $3500
- · Z (S) $7000
1926.1053 B01
- Issued
- May 2, 2013
- Penalty
- Initial $7,000 · Current $3,500 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support. Location: On the roof of the house; a) Employees were using a ladder that did not extend three feet over the landing of the roof; on or about 03/29/13.
Recent events (2)
- · I (S) $3500
- · Z (S) $7000
More inspections at Vivint Solar Developer LLC