Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GARDNER DENVER THOMAS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of GARDNER DENVER THOMAS, INC. in 4601 CENTRAL AVE, MONROE, LA 71203 (NAICS 333912). OSHA activity number 338992803.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Gardner Denver Thomas, INC. — free Get an email when a new federal OSHA severe-injury report for Gardner Denver Thomas, INC. is published. One employer, no account, unsubscribe in one click.
Site address
4601 CENTRAL AVE
City
MONROE
State
LA
ZIP
71203
Mailing
4601 CENTRAL AVE, MONROE, LA 71203
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333912
Employees
200
Ownership type
A

2 citations on file for this inspection.

1910.178 G02

Deleted Serious Gravity 5 1 instance 5 exposed
Issued
May 15, 2013
Abate by
May 30, 2013
Penalty
Initial $2,430 · Current $0 Reduced
29 CFR 1910.178(g)(2): Facilities shall be provided for flushing and neutralizing spilled electrolyte, for fire protection, for protecting charging apparatus from damage by trucks, and for adequate ventilation for dispersal of fumes from gassing batteries.  On or about 03/14/2013, on the northwest corner of the facility adjacent to the chemical storage room ("oil room"), the employer allowed employees to use a battery charging station with an inadequate eyewash bottle. This bottle did not meet the requirements of an eye wash station per ANSI Z358.1, in that:  a) A means shall be provided to flush both eyes simultaneously  b) Capable of delivering water to both eyes not less than 1.5 liters per minute  c) Allow eyes to be held open by hand while the system is flushing  d) and provide 15 minutes of flush water
Recent events (2)
  • — I (S) $0
  • — Z (S) $2430

1910.36 D

Other-than-serious 1 instance 200 exposed
Issued
May 15, 2013
Abate by
Jun 4, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.36(d): An exit door must be unlocked.  On or about 03/14/2013, the employer failed to ensure that the exit door in the shipping department was unlocked.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Gardner Denver Thomas, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338992803.