SHEBOYGAN, WI —
OSHA Inspection: GARDNER DENVER THOMAS, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of GARDNER DENVER THOMAS, INC. in 1419 ILLINOIS AVENUE, SHEBOYGAN, WI 53081 (NAICS 331523). OSHA activity number 345348486.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GARDNER DENVER THOMAS, INC.
- Site address
- 1419 ILLINOIS AVENUE
- City
- SHEBOYGAN
- State
- WI
- ZIP
- 53081
- Mailing
- 1419 ILLINOIS AVENUE, SHEBOYGAN, WI 53081
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331523
- Employees
- 85
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C07 I A
- Issued
- Oct 12, 2021
- Abate by
- Nov 19, 2021
- Penalty
- Initial $13,653 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control: On or about June 1, 2021 at a facility located at 1419 Illinois Avenue, Sheboygan, WI 53081; a Machine Operator employee and a Group Leader employee did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available, and the methods or means necessary for energy isolation and control when the employees were exposed to hazardous energy when troubleshooting a punch die in the Trim Press 4283 (Falls Press Serial #C1200003TP).
Recent events (2)
- — I (S) $0
- — Z (S) $13653
1910.147 D
- Issued
- Oct 12, 2021
- Abate by
- Nov 19, 2021
- Penalty
- Initial $0 · Current $9,557
General-duty citation text
29 CFR 1910.147(d): The established procedures for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): On or about June 1, 2021 at a facility located at 1419 Illinois Avenue, Sheboygan, WI 53081; an employee was exposed to machine hazards associated with nip-points/caught-between hazards when they were troubleshooting a sliding trim punch on Trim Press 4283 (Falls Press Serial #C1200003TP). The employer did not ensure that employees implemented energy control application steps prior to allowing them to troubleshooting the Trim Press' punch die. The machine's operator activated the press while another employee's hand was still in the punch die resulting in an amputation. The press was not deenergized prior to the employees engaging in servicing/maintenance activity. As a result, the remaining applicable energy control elements, involving machine isolation [1910.147(d)(3)], lockout/tagout device application [1910.147(d)(4)], dissipation of residual energy [1910.147(d)(5)(i)], and verification of isolation [1910.147(d)(6)] were not implemented to protect employees from machine servicing hazards.
Recent events (2)
- — I (S) $9557.1
- — Z (S) $0
1910.147 F03 II
- Issued
- Oct 12, 2021
- Abate by
- Nov 19, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(f)(3)(ii): Group lockout or tagout devices shall be used in accordance with the procedures required by paragraph (c)(4) of this section including, but not necessarily limited to, the following specific requirements: On or about June 1, 2021 at a facility located at 1419 Illinois Avenue, Sheboygan, WI 53081; employees did not use group lockout or tagout devices when two employees were troubleshooting the punch die on Trim Press 4283(Falls Press Serial #C1200003TP). The machine's operator activated the press while another employee's hand was still on the punch die resulting in an amputation.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Gardner Denver Thomas, INC.
View Gardner Denver Thomas, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 331523)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345348486.