ORRVILLE, OH —
OSHA Inspection: SMITH DAIRY PRODUCTS COMPANY INC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of SMITH DAIRY PRODUCTS COMPANY INC in 307 N. VINE STREET, ORRVILLE, OH 44667 (NAICS 311520). OSHA activity number 338996655.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SMITH DAIRY PRODUCTS COMPANY INC
- Site address
- 307 N. VINE STREET
- City
- ORRVILLE
- State
- OH
- ZIP
- 44667
- Mailing
- P O BOX 638, ORRVILLE, OH 44667
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311520
- Employees
- 110
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.119 D03 I F
- Issued
- Jul 10, 2013
- Abate by
- Aug 14, 2013
- Penalty
- Initial $4,250 · Current $2,550 Reduced
General-duty citation text
29 CFR 1910.119(d)(3)(i)(F): Process safety information pertaining to the equipment did not include the design codes and standards employed: The process safety information did not include the design codes and standards utilized for the design of the emergency shutdown system and the compressor cutouts including the high level, low and high pressure discharge, oil pressure and temperature interlocks.
Recent events (2)
- — I (S) $2550
- — Z (S) $4250
1910.119 D03 II
- Issued
- Jul 10, 2013
- Abate by
- Aug 14, 2013
- Penalty
- Initial $4,250 · Current $2,550 Reduced
General-duty citation text
29 CFR 1910.119(d)(3)(ii): The employer did not document that equipment complied with recognized and generally accepted good engineering practices: Relief header A which is connected to pressure safety relief valves in the milk process engine room discharges to an area on the roof where employees are required to work on a regular basis to monitor the operation of the refrigeration system. Employees working in the area can be exposed to high levels of ammonia in the event that a relief valve activates. Refer to ANSI/ASHRAE, Safety Standard for Ammonia Refrigeration Systems 15, which states in section 9.7.8 that discharge must be 15 feet above the working surface.
Recent events (2)
- — I (S) $2550
- — Z (S) $4250
1910.119 E03 V
- Issued
- Jul 10, 2013
- Abate by
- Aug 14, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.119(e)(3)(v): The process hazard analysis did not address the hazards of facility siting: The process hazard analysis done in 2011 did not address the hazard of discharge of ammonia near areas where employees work. Relief header A which is connected to pressure safety relief valves in the milk process engine room discharges to an area on the roof where employees are required to work on a regular basis to monitor the operation of the refrigeration system. Employees working in the area can be exposed to high levels of ammonia in the event that a relief valve activates. Refer to ANSI/ASHRAE, Safety Standard for Ammonia Refrigeration Systems 15, which states in section 9.7.8 that discharge must be 15 feet above the working surface:
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.119 F01 III B
- Issued
- Jul 10, 2013
- Abate by
- Aug 14, 2013
- Penalty
- Initial $4,250 · Current $2,550 Reduced
General-duty citation text
29 CFR 1910.119(f)(1)(iii)(B): The employer's written operating procedures covering safety and health considerations did not address the precautions necessary to prevent exposure, including engineering controls, administrative controls, and personal protective equipment: The procedures developed for periodic oil draining from the ammonia refrigeration system did not include a determination on the need for respirators to protect employees from exposure to ammonia during the oil draining procedure.
Recent events (2)
- — I (S) $2550
- — Z (S) $4250
1910.119 J02
- Issued
- Jul 10, 2013
- Abate by
- Aug 14, 2013
- Penalty
- Initial $4,250 · Current $2,550 Reduced
General-duty citation text
29 CFR 1910.119(j)(2): The employer did not establish and implement written procedures to maintain the on-going mechanical integrity of process equipment: No specific procedures were developed to inspect ammonia piping and vessels. Employees are told to look for corrosion and leaks but no written guidance is provided for exactly what to look for during inspections of insulated and uninsulated equipment.
Recent events (2)
- — I (S) $2550
- — Z (S) $4250
1910.119 K02
- Issued
- Jul 10, 2013
- Abate by
- Aug 14, 2013
- Penalty
- Initial $4,250 · Current $2,550 Reduced
General-duty citation text
29 CFR 1910.119(k)(2): The hot work permit did not document that the fire prevention and protection requirements in 29 CFR 1910.252(a) had been implemented prior to beginning the hot work operations: Hot work permits utilized for work done on 5/29, 31 and 6/5/13 were not completed in that the, "required precaution checklist", was not filled out to document that the protection requirements were implemented.
Recent events (2)
- — I (S) $2550
- — Z (S) $4250
1910.120 Q02 XI
- Issued
- Jul 10, 2013
- Abate by
- Aug 30, 2013
- Penalty
- Initial $3,400 · Current $2,550 Reduced
General-duty citation text
29 CFR 1910.120(q)(2)(xi): The emergency response plan did not address, to the extent not addressed elsewhere, PPE and emergency equipment: The plan for response to ammonia leaks states that Self Contained Breathing Apparatus (SCBA) will be used during the response, but medical reports for at least two responders state that they are not medically permitted to use SCBAs. The plan should address PPE for employees who respond but are not cleared to use SCBAs.
Recent events (2)
- — I (S) $2550
- — Z (S) $3400
1910.134 F01
- Issued
- Jul 10, 2013
- Abate by
- Aug 30, 2013
- Penalty
- Initial $4,250 · Current $0 Reduced
General-duty citation text
29 CFR 1910.134(f)(1): The employer did not ensure that employees using a tight-fitting facepiece respirator pass an appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT) as stated in 29 CFR 1910(f): The plan for response to ammonia leaks states that Self Contained Breathing Apparatus (SCBA) will be used during the response. A QNFT is required for this respirator but no fit testing was done for employees who respond to leaks.
Recent events (2)
- — I (S) $0
- — Z (S) $4250
1910.120 Q08 I
- Issued
- Jul 10, 2013
- Abate by
- Aug 14, 2013
- Penalty
- Initial $4,250 · Current $2,550 Reduced
General-duty citation text
29 CFR 1910.120(q)(8)(i): Employees who were trained in accordance with 29 CFR 1910.120(q)(6) did not receive annual refresher training of sufficient content and duration to maintain their competencies or did not demonstrate competency in those areas at least yearly: Hazardous materials technician refresher training has not been provided for employees in 2012 or 2013 by the day of the inspection. Training is required on an annual basis.
Recent events (2)
- — I (S) $2550
- — Z (S) $4250
More inspections at Smith Dairy Products Company INC
View Smith Dairy Products Company INC's full OSHA safety record →
More inspections in this industry (NAICS 311520)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338996655.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.