OSHA Inspection: CLEARWOOD CUSTOM CARPENTRY & MILLWORK, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CLEARWOOD CUSTOM CARPENTRY & MILLWORK, LLC in 617 W. MANLIUS STREET, EAST SYRACUSE, NY 13057 (NAICS 321918). OSHA activity number 338998669.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Clearwood Custom Carpentry & Millwork, LLC for free Get an email when a new federal OSHA severe-injury report for Clearwood Custom Carpentry & Millwork, LLC is published. One employer, no account, unsubscribe in one click.
Site address
617 W. MANLIUS STREET
City
EAST SYRACUSE
State
NY
ZIP
13057
Mailing
617 W. MANLIUS STREET, EAST SYRACUSE, NY 13057
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321918
Employees
27
Ownership type
A

12 citations on file for this inspection.

1910.22 B01

Serious Gravity 1 2 instances 2 exposed
Issued
Apr 18, 2013
Abate by
May 23, 2013
Penalty
Initial $1,785 · Current $893 Reduced
29 CFR 1910.22(b)(1): Aisles and passageways were not kept clear and in good repair, with no obstruction across or in aisles that could create a hazard:    a)  Custom/Commercial Dept., on or about 4/10/13:   Two four way receptacle outlets each with a three way airline connector protruding from the floor created a tripping hazard.    Abatement certification must be submitted for this item.
Recent events (3)
  • · J (S) $892.5
  • · C (S) $1785
  • · Z (S) $1785

1910.22 C

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 18, 2013
Abate by
May 23, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.22(c): Covers and/or guardrails were not provided to protect personnel from the hazards of open pits, tanks, vats, ditches, etc.:  a)  Electrical/Compressor Room, on or about 4/10/13:  Floor drain was not adequately guarded in that the opening measured approx. 16" X 9" X 9" deep.  Abatement certification must be submitted for this item.
Recent events (3)
  • · 3 (S) $0
  • · C (S) $0
  • · Z (S) $0

1910.107 B05 IV

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 18, 2013
Abate by
May 23, 2013
Penalty
Initial $2,380 · Current $1,190 Reduced
29 CFR 1910.107(b)(5)(iv): Space within the spray booth on the downstream and upstream sides of filters were not protected with approved automatic sprinklers:    a)  Finishing Dept., Drying Area, on or about 4/10/13:  A spray booth used for spraying stains was not provided with automatic sprinklers.    Abatement certification must be submitted for this item.
Recent events (3)
  • · J (S) $1190
  • · C (S) $2380
  • · Z (S) $2380

1910.212 A01

Serious Gravity 5 6 instances 6 exposed
Issued
Apr 18, 2013
Abate by
May 23, 2013
Penalty
Initial $2,380 · Current $1,190 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:     a)  Tool Room, on or about 4/10/13:  Rotating chuck on a Ryobi drill press and a Central Machinery drill press were not guarded.     b)  Custom Shop, on or about 4/10/13:  Rotating chuck and spindle on a Clausing drill press were not guarded.     c)  Box Assembly, on or about 4/10/13:  Rotating chuck on a Central Machinery drill press was not guarded.     d)  Box Assembly, on or about 4/10/13:  Unused portion of blade on a Jet horizontal bandsaw was not guarded.     e)  Custom/Commercial Shop, on or about 4/10/13:  Rotating chuck on a Jet drill press was not guarded.     Abatement certification must be submitted for these items.
Recent events (3)
  • · J (S) $1190
  • · C (S) $2380
  • · Z (S) $2380

1910.212 B

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 18, 2013
Abate by
May 23, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:  a)  Custom/Commercial Dept., on or about 4/10/13:  A Jet drill press was not anchored to prevent walking or moving.  Abatement certification must be submitted for this item.
Recent events (3)
  • · 3 (S) $0
  • · C (S) $0
  • · Z (S) $0

1910.213 P04

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 18, 2013
Abate by
May 23, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.213(p)(4): Belt sanding machinery was not provided with a guard at each nip point where the sanding belt ran onto a pulley, to prevent the operator's hands or fingers from coming into contact with nip points:  a)  Custom/Commercial Dept., on or about 4/10/13:  Ingoing nip points on a Powermatic edge sander were not adequately guarded.  Abatement certification must be submitted for this item.
Recent events (3)
  • · 3 (S) $0
  • · C (S) $0
  • · Z (S) $0

1910.213 A09

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 18, 2013
Abate by
May 23, 2013
Penalty
Initial $2,380 · Current $1,190 Reduced
29 CFR 1910.213(a)(9): All belts, pulleys, gears, shafts, and moving parts were not guarded in accordance with the specific requirements of 1910.219:    a)  Box Assembly, on or about 4/10/13:  V belt and pulleys driving a Jet horizontal bandsaw were not guarded.    Abatement certification must be submitted for this item.
Recent events (3)
  • · J (S) $1190
  • · C (S) $2380
  • · Z (S) $2380

1910.215 A02

Serious Gravity 1 2 instances 1 exposed
Issued
Apr 18, 2013
Abate by
May 23, 2013
Penalty
Initial $1,785 · Current $893 Reduced
29 CFR 1910.215(a)(2): Abrasive wheel(s) used on grinding machinery were not provided with safety guard(s) which covered the spindle end, nut, flange projections:    a)  Box Assembly, on or about 4/10/13:  Dayton bench grinder was not provided safety guards over the spindle end, nut and flange projections.    Abatement certification must be submitted for this item.
Recent events (3)
  • · J (S) $892.5
  • · C (S) $1785
  • · Z (S) $1785

1910.215 A04

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 18, 2013
Abate by
May 23, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.215(a)(4): Grinding machinery was not used with work rest(s) to support offhand grinding work:  a)  Box Assembly, on or about 4/10/13:  Dayton bench grinder was not provided with a work rest for the right abrasive wheel.  Abatement certification must be submitted for this item.
Recent events (3)
  • · 3 (S) $0
  • · C (S) $0
  • · Z (S) $0

1910.215 B09

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 18, 2013
Abate by
May 23, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): Guard for abrasive wheel machine where the operator stands in front of the machine was not constructed so that the peripheral protecting member could be adjusted to the constantly decreasing diameter of the wheel:  a)  Box Assembly, on or about 4/10/13:  Dayton bench grinder was not provided with a tongue guard for the right abrasive wheel.  Abatement certification must be submitted for this item.
Recent events (3)
  • · 3 (S) $0
  • · C (S) $0
  • · Z (S) $0

1910.305 B01 II

Serious Gravity 1 2 instances 1 exposed
Issued
Apr 18, 2013
Abate by
May 23, 2013
Penalty
Initial $1,785 · Current $0 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings were not effectively closed:    a)  Electrical/Compressor Room, on or about 4/10/13:  A duplex receptacle outlet had two knockouts missing.    Abatement certification must be submitted for this item.
Recent events (3)
  • · J (S) $0
  • · C (S) $1785
  • · Z (S) $1785

1910.305 B02 I

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 18, 2013
Abate by
May 23, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:  a)  Electrical/Compressor Room, on or about 4/10/13:  A junction box had a cover missing.  Abatement certification must be submitted for this item.