OSHA Inspection: BRUNELLE BROS. ELECTRIC, INC.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of BRUNELLE BROS. ELECTRIC, INC. in 5-10 DIGITAL DR., NASHUA, NH 03062 (NAICS 238210). OSHA activity number 339004277.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Brunelle Bros. Electric, INC. for free Get an email when a new federal OSHA severe-injury report for Brunelle Bros. Electric, INC. is published. One employer, no account, unsubscribe in one click.
Site address
5-10 DIGITAL DR.
City
NASHUA
State
NH
ZIP
03062
Mailing
P.O. BOX 836, BILLERICA, MA 01821
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
30
Ownership type
A

4 citations on file for this inspection.

1926.403 I02

Serious Gravity 5 1 instance 18 exposed
Issued
May 10, 2013
Abate by
May 10, 2013
Penalty
Initial $3,500 · Current $1,750 Reduced
29 CFR 1926.403(i)(2): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures:    a. Site - On or about April 9, 2013, live electrical parts were not guarded against accidental contact.
Recent events (2)
  • · I (S) $1750
  • · Z (S) $3500

1926.405 A02 II E

Serious Gravity 5 3 instances 18 exposed
Issued
May 10, 2013
Abate by
May 10, 2013
Penalty
Initial $3,500 · Current $1,750 Reduced
29 CFR 1926.405(a)(2)(ii)(E): Lamps used in temporary wiring for general illumination were not protected from accidental contact or breakage:    a. Site - On or about April 9, 2013, temporary lighting was not guarded to prevent contact or accidental breakage.
Recent events (2)
  • · I (S) $1750
  • · Z (S) $3500

1926.405 J01 I

Serious Gravity 5 1 instance 18 exposed
Issued
May 10, 2013
Abate by
May 10, 2013
Penalty
Initial $3,500 · Current $1,750 Reduced
29 CFR 1926.405(j)(1)(i): Fixtures, lampholders, lamps, rosettes, or receptacles had live parts normally exposed to employee contact:    a. Site - On or about April 9, 2013, a receptacle cover was not provided for the electrical outlet in use.
Recent events (2)
  • · I (S) $1750
  • · Z (S) $3500

1926.405 J01 II

Serious Gravity 5 2 instances 18 exposed
Issued
May 10, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.405(j)(1)(ii): Fixtures, lampholders, rosettes, or receptacles were not securely supported:  Instance a. Building #4 second floor - On or about April 9, 2013, electrical receptacle in use was not securely supported.  Instance a. Building #4 third floor - On or about April 9, 2013, electrical receptacle in use was not securely supported.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

View Brunelle Bros. Electric, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339004277.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.