SHAMROCK, TX ·
OSHA Inspection: PERMIAN WELL SERVICE LTD.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PERMIAN WELL SERVICE LTD. in STEARNS 103-STEARNS RANCH KELTON-TX, SHAMROCK, TX 79079 (NAICS 213112). OSHA activity number 339006439.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PERMIAN WELL SERVICE LTD.
- Site address
- STEARNS 103-STEARNS RANCH KELTON-TX
- City
- SHAMROCK
- State
- TX
- ZIP
- 79079
- Mailing
- PO BOX 177, RINGWOOD, OK 73768
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213112
- Employees
- 4
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
1910.23 C01
- Issued
- May 29, 2013
- Abate by
- Jun 13, 2013
- Penalty
- Initial $2,618 · Current $1,571 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards: On or about March 6, 2013 the employer did not ensure that the work-over rig's platform was properly guarded with standard railing. The work platform lacked railing, exposing employees to fall hazards above 4 feet.
Recent events (2)
- · I (S) $1570.8
- · Z (S) $2618
1910.23 D01 III
- Issued
- May 29, 2013
- Abate by
- Jun 17, 2013
- Penalty
- Initial $2,618 · Current $1,571 Reduced
General-duty citation text
29 CFR 1910.23(d)(1)(iii): Stairway(s) less than 44 inches wide having both sides open, did not have one stair railing on each side: On or about March 6, 2013 the employer did not ensure that the work-over rig's stairs (6 risers) leading up to the work platform was properly equipped with standard stair railing.
Recent events (2)
- · I (S) $1570.8
- · Z (S) $2618
1910.23 E02
- Issued
- May 29, 2013
- Abate by
- Jun 17, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(e)(2): Stair rails did not consist of a top rail, intermediate rail and/or posts, with the vertical height not more than 34 inches (86.36 cm) nor less than 30 inches (76.2 cm) from upper surface of top rail to surface of tread in line with with face of riser at forward edge of tread: On or about March 6, 2013 the employer did not ensure that the work-over rig's stairs (6 risers) leading up to the work platform was properly equipped with standard stair railing. The stairway was equipped with one rail that measured 13 inches in height.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.24 D
- Issued
- May 29, 2013
- Abate by
- Jun 17, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.24(d): Fixed stairways did not have a minimum width of 22 inches: On or about March 6, 2013 the employer did not ensure that the work-over rig's stairway, leading up to the platform, was over 22 inches in width.
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections at Permian Well Service LTD.
View Permian Well Service LTD.'s full OSHA safety record →
More inspections in this industry (NAICS 213112)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339006439.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.