DEDEDO, GU —
OSHA Inspection: DHX
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DHX in 501 HARMON ROAD DEDEO, GU 96929, DEDEDO, GU 96929 (NAICS 493110). OSHA activity number 339006850.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DHX
- Site address
- 501 HARMON ROAD DEDEO, GU 96929
- City
- DEDEDO
- State
- GU
- ZIP
- 96929
- Mailing
- P.O. BOX 25089 GMF, GU 96921, BARRIGADA, GU 96921
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 493110
- Employees
- 17
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.36 D01
- Issued
- Jun 11, 2013
- Abate by
- Jun 11, 2013
- Penalty
- Initial $1,156 · Current $1,156
General-duty citation text
29 CFR 1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge: a) Warehouse, Side Exit Door - Noted on or about 4/15/13 and at times prior thereto, an exit door handle had a wire rope wrapped around it preventing egress.
Recent events (1)
- — Z (S) $1156
1910.303 B02
- Issued
- Jun 11, 2013
- Abate by
- Jul 5, 2013
- Penalty
- Initial $1,360 · Current $1,360
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) Warehouse - Noted on or about 4/16/13 and at times prior thereto, one relocatable power tab was used as a substitute for fixed wiring to energize the FM paint dispenser and FM paint mixer.
Recent events (1)
- — Z (S) $1360
1910.1200 E01
- Issued
- Jun 11, 2013
- Abate by
- Jul 5, 2013
- Penalty
- Initial $1,360 · Current $1,360
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a) Warehouse/Vehicle Maintenance Shop - Noted on or about 4/16/13 and at times prior thereto, it was noted that the employer did not develop a written Hazard Communication Program for employees who were exposed to the hazards of flammable and combustible chemicals such as, but not limited to, paints, acetone, diesel fuel, and welding gases. Additionally, large amounts of flammable liquids are stored in the warehouse.
Recent events (1)
- — Z (S) $1360
1910.22 A01
- Issued
- Jun 11, 2013
- Abate by
- Jul 5, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, and service rooms shall be kept clean and orderly and in a sanitary condition. a) Vehicle Maintenance - Noted on or about 4/16/13 and at times prior thereto, the general work area and walkways were excessively cluttered with part, tools, and rubbish thereby creating fall hazards.
Recent events (1)
- — Z (O) $0
1910.178 L04 III
- Issued
- Jun 11, 2013
- Abate by
- Jul 5, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: a) Warehouse - Noted on or about 4/16/13 and at times prior thereto, the employer did not provide an employee with forklift refresher training at least once every three years.
Recent events (1)
- — Z (O) $0
1910.178 P01
- Issued
- Jun 11, 2013
- Abate by
- Jun 18, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s): (a) Warehouse - Noted on or about 4/16/13 and at times prior thereto, the Nissan L6 forklift did not have brake lights that were operational when the brake pedal was depressed.
Recent events (1)
- — Z (O) $0
1910.305 G02 III
- Issued
- Jun 11, 2013
- Abate by
- Jun 18, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws. a. Warehouse - Noted on or about 4/16/13 and at times thereto, a female plug cord belonging to the FM paint mixer was pulled from it's fittings and the live inner conductors were exposed.
Recent events (1)
- — Z (O) $0
More inspections at DHX
View DHX's full OSHA safety record →
More inspections in this industry (NAICS 493110)
More inspections in GU
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339006850.