MEQUON, WI —
OSHA Inspection: TELSMITH, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of TELSMITH, INC. in 10910 NORTH INDUSTRIAL DRIVE, MEQUON, WI 53092 (NAICS 333120). OSHA activity number 339007809.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TELSMITH, INC.
- Site address
- 10910 NORTH INDUSTRIAL DRIVE
- City
- MEQUON
- State
- WI
- ZIP
- 53092
- Mailing
- 10910 N. INDUSTRIAL DR., MEQUON, WI 53092
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333120
- Employees
- 294
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.23 D01 III
- Issued
- May 30, 2013
- Abate by
- Jun 11, 2013
- Penalty
- Initial $2,550 · Current $2,550
General-duty citation text
29 CFR 1910.23(d)(1)(iii): Stairway(s) less than 44 inches wide having both sides open, did not have one stair railing on each side: (a) In the production area at the Whitney 661 burn table, the open-sided fixed staircase with four risers did not have stair railings on each side. Employees used these stairs to access the top of the burn table and were exposed to fall hazards.
Recent events (2)
- — I (S) $2550
- — Z (S) $2550
1910.243 C03
- Issued
- May 30, 2013
- Abate by
- Jun 6, 2013
- Penalty
- Initial $2,550 · Current $2,550
General-duty citation text
29 CFR 1910.243(c)(3): Abrasive wheels used on vertical portable grinder(s) (right angle head grinders) were not provided with safety guard(s) having a maximum exposure angle of 180 degrees and located between the operator and wheel: (a) In the production area at the Whitney 661 and Messer burn tables, the employer did not ensure that proper guarding was provided for abrasive wheels on the Ingersoll-Rand portable grinding equipment. Standard guarding on these grinders were for Type 27 and 28 abrasive wheels. Employees were using Type 11 wheels which were not adequately guarded.
Recent events (2)
- — I (S) $2550
- — Z (S) $2550
1910.254 D09 III
- Issued
- May 30, 2013
- Abate by
- Jun 5, 2013
- Penalty
- Initial $4,250 · Current $0 Reduced
General-duty citation text
29 CFR 1910.254(d)(9)(iii): Cables with damaged insulation or exposed bare conductors were not replaced: (a) In Bay 109 to 111, the Lincoln Electric AC/DC Arc Welder (Model TM-500/500; S/N: AC-403666) was in service and had a torn stinger cord covered with electrical tape. The employer did not ensure that the damaged equipment was adequately repaired prior to being used.
Recent events (2)
- — I (O) $0
- — Z (S) $4250
1910.254 D09 I
- Issued
- May 30, 2013
- Abate by
- Jun 6, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.254(d)(9)(i): The operator did not report a defect or safety hazard to his supervisor and the use of the equipment was not discontinued until safety had been reassured. (a) In Bay 109 to 111, the employer did not ensure the Lincoln Electric AC/DC Arc Welder (Model TM-500/500; S/N: AC-403666) was removed from service and adequately repaired. The stinger cord was torn and covered with electrical tape.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.147 C06 I
- Issued
- May 30, 2013
- Abate by
- Jun 18, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: (a) The employer did not review at least annually each authorized employee's application of lockout/tagout for the energy control procedures being inspected to ensure proficiency with controlling hazardous energy has been maintained.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 F05
- Issued
- May 30, 2013
- Abate by
- Jun 11, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(5): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged, or marked with the identity and appropriate hazard warnings regarding the chemicals contained therein: (a) In the production area at the Whitney 661 burn table, the employer did not ensure all chemical containers of Mobil DTE 26 oil were labeled with a chemical identity and hazard warnings.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Telsmith, INC.
View Telsmith, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 333120)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339007809.