TAMUNING, GU —
OSHA Inspection: HFM FOOD SERVICE
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of HFM FOOD SERVICE in GUERRERO ST., HARMON INDUSTRIAL PARK ROAD, TAMUNING, GU 96913 (NAICS 493110). OSHA activity number 339015935.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HFM FOOD SERVICE
- Site address
- GUERRERO ST., HARMON INDUSTRIAL PARK ROAD
- City
- TAMUNING
- State
- GU
- ZIP
- 96913
- Mailing
- P.O. BOX 21089, BARRIGADA, GU 96921
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 493110
- Employees
- 7
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.157 E02
- Issued
- Jul 10, 2013
- Abate by
- Jul 22, 2013
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly: This violation was discovered on April 16, 2013; where the fire extinguishers in the facility had not been inspected on a monthly basis.
Recent events (1)
- — Z (S) $1200
1910.157 E03
- Issued
- Jul 10, 2013
- Abate by
- Jul 22, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(3): The date of the annual maintenance check of portable fire extinguishers was not recorded: This violation was discovered on April 16, 2013; where the fire extinguishers in the facility had not received annual maintenance checks/inspections.
Recent events (1)
- — Z (S) $0
1910.157 G02
- Issued
- Jul 10, 2013
- Abate by
- Jul 29, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(g)(2): The employer failed to provide an educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting to all employees upon initial employment, and at least annually thereafter: This violation was discovered on April 16, 2013 throughout the warehouse where the employees expected to use fire extinguishers were not trained in the general principles and operation of fire extinguishers and hazards involved with incipient stage fire fighting.
Recent events (1)
- — Z (S) $0
1910.178 L04 III
- Issued
- Jul 10, 2013
- Abate by
- Jul 29, 2013
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance shall be conducted at least once every three years. This violation was discovered on April 16, 2013; where the employer did not evaluate each powered industrial truck operator's ability to operate a forklift.
Recent events (1)
- — Z (S) $1600
1910.178 L06
- Issued
- Jul 10, 2013
- Abate by
- Jul 29, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l): This violation was discovered on April 16, 2013; where the employer did not maintain certification records of any formal forklift operator training or of any three year forklift operator performance evaluations.
Recent events (1)
- — Z (S) $0
1910.303 F02
- Issued
- Jul 10, 2013
- Abate by
- Jul 22, 2013
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: This violation was discovered on April 16, 2013; where the circuit panel was not marked to indicate its purpose nor was it arranged so the purpose was evident.
Recent events (1)
- — Z (S) $1200
1910.305 B02 I
- Issued
- Jul 10, 2013
- Abate by
- Jul 22, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: This violation was discovered on April 16, 2013; where the cover was missing from the warehouse building circuit panel junction box.
Recent events (1)
- — Z (S) $0
1910.178 P01
- Issued
- Jul 10, 2013
- Abate by
- Jul 22, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s): This violation was discovered on April 16, 2013; where a Hyster forklift had a defective back-up alarm and was not taken out of service.
Recent events (1)
- — Z (O) $0
More inspections at HFM Food Service
View HFM Food Service's full OSHA safety record →
More inspections in this industry (NAICS 493110)
More inspections in GU
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339015935.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.