PETERSBURG, TX —
OSHA Inspection: WYLIE & SON INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of WYLIE & SON INC. in 101 N. MAIN, PETERSBURG, TX 79250 (NAICS 333111). OSHA activity number 339016263.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WYLIE & SON INC.
- Site address
- 101 N. MAIN
- City
- PETERSBURG
- State
- TX
- ZIP
- 79250
- Mailing
- P.O. BOX 100, PETERSBURG, TX 79250
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333111
- Employees
- 89
- Ownership type
- A
Citations
14 citations on file for this inspection.
1910.107 B10
- Issued
- Sep 30, 2013
- Abate by
- Oct 10, 2013
- Penalty
- Initial $3,825 · Current $3,825
General-duty citation text
29 CFR 1910.107(b)(10): Illumination panels did not effectively isolate the spraying area from the area in which the lighting unit was located. On or about April 19, 2013, employees were exposed to explosion/fire hazards in that the employer did not ensure that illumination panels were not cracked in spray paint booths. a) The north spray paint booth. b) The south spray paint booth.
Recent events (1)
- — Z (S) $3825
1910.147 C04 I
- Issued
- Sep 30, 2013
- Abate by
- Oct 10, 2013
- Penalty
- Initial $2,295 · Current $2,295
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about April 19, 2013, employees were exposed to unexpected start-up hazards in that the employer did not develop and implement energy control procedures including the following, but not limited to: a) Summit Shear, model #10X1/4h. b) Scotchman Ironworker, model #8507-14M. c) Version Brakepress. d) Accupress Brakepress, model #7250.
Recent events (1)
- — Z (S) $2295
1910.178 L01 I
- Issued
- Sep 30, 2013
- Abate by
- Oct 10, 2013
- Penalty
- Initial $2,295 · Current $2,295
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator was competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): On or about April 19, 2013, employees exposed to caught-in-between hazards in that the employer did not ensure that employees were trained in forklift operation.
Recent events (1)
- — Z (S) $2295
1910.178 L04 III
- Issued
- Sep 30, 2013
- Abate by
- Oct 10, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: On or about April 19, 2013, employees exposed to struck-by and caught-in-between hazards in that the employer did not ensure employees who operated forklifts were evaluated at least once every 3 years.
Recent events (1)
- — Z (S) $0
1910.179 B05
- Issued
- Sep 30, 2013
- Abate by
- Oct 10, 2013
- Penalty
- Initial $3,060 · Current $3,060
General-duty citation text
29 CFR 1910.179(b)(5): The rated load of crane(s) was not plainly marked on each side of the crane: On or about April 19, 2013, employees exposed to struck-by hazards in that the employer did not ensure that a CM Shopstar crane was labeled with the rated load marking.
Recent events (1)
- — Z (S) $3060
1910.179 J02 III
- Issued
- Sep 30, 2013
- Abate by
- Oct 10, 2013
- Penalty
- Initial $3,060 · Current $3,060
General-duty citation text
29 CFR 1910.179(j)(2)(iii): Monthly inspections of hooks, with a certification record which include the date of inspection, the signature of the person who performed the inspection and the serial number, or other identifier, of the hook inspected, were not performed: On or about April 19, 2013, employees were exposed to struck-by hazards in that the employer did not conduct and certify daily inspections and / or monthly inspections.
Recent events (1)
- — Z (S) $3060
1910.179 J02 IV
- Issued
- Sep 30, 2013
- Abate by
- Oct 10, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.179(j)(2)(iv): Monthly inspections of hoist chains, with a certification record which includes the date of inspection, the signature of the person who performed the inspection and an identifier of the chain which was inspected, were not performed: On or about April 19, 2013, employees were exposed to struck-by hazards in that the employer did not conduct and certify monthly inspections on the chains.
Recent events (1)
- — Z (S) $0
1910.212 A03 II
- Issued
- Sep 30, 2013
- Abate by
- Oct 10, 2013
- Penalty
- Initial $3,060 · Current $3,060
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): On or about April 19, 2013, employees were exposed to caught by hazards in that the employer did not guard a lathe chuck.
Recent events (1)
- — Z (S) $3060
1910.219 D01
- Issued
- Sep 30, 2013
- Abate by
- Oct 10, 2013
- Penalty
- Initial $3,060 · Current $3,060
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): On or about April 19, 2013, employees were exposed to caught-in-between hazards in that the employer did not guard pulleys.
Recent events (1)
- — Z (S) $3060
1910.219 E03 I
- Issued
- Sep 30, 2013
- Abate by
- Oct 10, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o): On or about April 19, 2013, employees were exposed to caught-by hazards in that verticle and incline belts were not enclosed by a guard.
Recent events (1)
- — Z (S) $0
1910.303 B01
- Issued
- Sep 30, 2013
- Abate by
- Oct 10, 2013
- Penalty
- Initial $3,825 · Current $3,825
General-duty citation text
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees: On or about April 19, 2013, employees were exposed to electrical hazards in that equipment foot pedal cables outer insulations were not without damage. a) Summit shear. b) Scotchman Industries ironworker, Serial #3006M896. c) Geka Puma ironworker, Serial #1866.
Recent events (1)
- — Z (S) $3825
1910.305 B01 II
- Issued
- Sep 30, 2013
- Abate by
- Oct 10, 2013
- Penalty
- Initial $4,590 · Current $4,590
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: On or about April 19, 2013, employees were exposed to electrical hazards in that unused openings in electrical fixtures were not effectively closed. a) A breaker box, 120 volts used for light on the west side in doors and outdoors. b) Junction box on the spot welder cart used to tack weld the bands. c) The outlet where the welding equipment is plugged into.
Recent events (1)
- — Z (S) $4590
1910.305 B02 I
- Issued
- Sep 30, 2013
- Abate by
- Oct 10, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: On or about April 19, 2013, employees were exposed to electric hazards in that electrical fixtures had a cover and faceplate. a) A junction box did not have a cover. b) An outlet did not have a face plate.
Recent events (1)
- — Z (S) $0
1910.305 G01 III
- Issued
- Sep 30, 2013
- Abate by
- Oct 10, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iii): Flexible cords and cables were used for purposes prohibited by subparagraphs (A) through (E) of this paragraph: On or about April 19, 2013, employees were exposed to electric hazards in that the employer used the flexible cord on a fluorescent light fixture as permanent wiring.
Recent events (1)
- — Z (S) $0
More inspections at Wylie & SON INC.
View Wylie & SON INC.'s full OSHA safety record →
More inspections in this industry (NAICS 333111)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339016263.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.