ALBION, PA ·
OSHA Inspection: LESKO ENTERPRISES, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of LESKO ENTERPRISES, INC. in 21 EUCLID STREET, ALBION, PA 16401 (NAICS 326199). OSHA activity number 339017139.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LESKO ENTERPRISES, INC.
- Site address
- 21 EUCLID STREET
- City
- ALBION
- State
- PA
- ZIP
- 16401
- Mailing
- 21 EUCLID STREET, ALBION, PA 16401
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 39
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.219 D01
- Issued
- May 13, 2013
- Abate by
- Jun 7, 2013
- Penalty
- Initial $1,785 · Current $0 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): a.) Lesko Enterprises, Inc. / 21 Euclid Street, Albion, PA: On or about April 19, 2013 a grinder used to grind out of spec product was missing a portion of a guard over the pulley section of the machine. The pulley was located less than 3-feet above the floor.
Recent events (2)
- · I (S) $0
- · Z (S) $1785
1910.145 F05
- Issued
- May 13, 2013
- Abate by
- Jun 7, 2013
- Penalty
- Initial $0 · Current $1,785
General-duty citation text
29 CFR 1910.145(f)(5): Danger tags were not used where an immediate hazard presented a threat of death or serious injury to employees: a) Lesko Enterprises, Inc. / 21 Euclid Street Albion, PA: On or about April 19, 2013, a grinder used to grind out of spec material contained a damaged and missing section of guarding and damaged flexible cord. The machine was not tagged out and/or rendered safe through other equally effective methods such as locking it out or moving the machine to a secure location to prevent its use.
Recent events (2)
- · I (S) $1785
- · Z (S) $0
1910.219 M01 II
- Issued
- May 13, 2013
- Abate by
- Jun 7, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(m)(1)(ii): All metal guards should be free from burrs and sharp edges. a.) Lesko Enterprises, Inc. / 21 Euclid Street, Albion, PA: On or about April 19, 2013 a grinder used to grind out of spec product was missing a portion of a guard over the pulley section of the machine. The portion of the guard that remained had sharp edges.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.334 A02 II
- Issued
- May 13, 2013
- Abate by
- Jun 7, 2013
- Penalty
- Initial $2,380 · Current $0 Reduced
General-duty citation text
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposes an employee to injury and the defective or damaged item was not removed from service: a) Lesko Enterprises, Inc. / 21 Euclid Street, Albion, PA: On or about April 19, 2013 a plug in grinder used to grind out of spec product had damaged wiring. The flexible cords protective out layer was pulled from around the electrical wiring at the power supply box on the machine.
Recent events (2)
- · I (S) $0
- · Z (S) $2380
1910.305 G02 III
- Issued
- May 13, 2013
- Abate by
- Jun 7, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: a) Lesko Enterprises, Inc. / 21 Euclid Street, Albion, PA: On or about April 19, 2013 a plug in grinder used to grind out of spec product had damaged wiring. The flexible cords protective out layer was pulled from around the electrical wiring at the power supply box on the machine. Functional strain relief devices were not installed in/around the area where the flexible cord entered the machines power supply box.
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections at Lesko Enterprises, INC.
View Lesko Enterprises, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 326199)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339017139.