TAMUNING, GU —
OSHA Inspection: LIN-IAN METALS (GUAM) CORP.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of LIN-IAN METALS (GUAM) CORP. in 333 WEST HARMON INDUSTRIAL PARK ROAD, TAMUNING, GU 96913 (NAICS 332321). OSHA activity number 339018079.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LIN-IAN METALS (GUAM) CORP.
- Site address
- 333 WEST HARMON INDUSTRIAL PARK ROAD
- City
- TAMUNING
- State
- GU
- ZIP
- 96913
- Mailing
- 333 WEST HARMON INDUSTRIAL PARK ROAD, TAMUNING, GU 96913
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332321
- Employees
- 10
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.243 C04
- Issued
- Jun 27, 2013
- Abate by
- Jul 24, 2013
- Penalty
- Initial $1,600 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.243(c)(4): The angular exposure on the grinding wheel periphery and sides for safety guard(s) used on portable grinding machine(s) exceeded 180 degrees: At 333 West Harmon Industrial Park Road (warehouse) on April 23, 2013, the Bosch 1375A 4-1/2-in Angle Grinder, was missing its safety guard thus exposing the entire wheel.
Recent events (2)
- — I (S) $1200
- — Z (S) $1600
1910.303 G01
- Issued
- Jun 27, 2013
- Abate by
- Jul 24, 2013
- Penalty
- Initial $1,600 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: At 333 West Harmon Industrial Park Road (warehouse, tool storage area) on April 23, 2013, sufficient access and working space to the main electrical panel was not provided and maintained to permit ready and safe operation and maintenance of main electrical panel.
Recent events (2)
- — I (S) $1200
- — Z (S) $1600
1910.304 G05
- Issued
- Jun 27, 2013
- Abate by
- Jul 24, 2013
- Penalty
- Initial $1,200 · Current $900 Reduced
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: At 333 West Harmon Industrial Park Road (warehouse) on April 23, 2013, the Bosch 1375A 4-1/2-in Angle Grinder was missing the ground pin.
Recent events (2)
- — I (S) $900
- — Z (S) $1200
1910.157 E02
- Issued
- Jun 27, 2013
- Abate by
- Jul 24, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly: At 333 West Harmon Industrial Park Road (warehouse, n. wall) on April 23, 2013, the portable ABC dry chemical fire extinguisher was not visually inspected monthly. The inspection tag affixed to the extinguisher indicates that the last visual inspection was conducted on February 2005.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Lin-Ian Metals (Guam) Corp.
View Lin-Ian Metals (Guam) Corp.'s full OSHA safety record →
More inspections in this industry (NAICS 332321)
More inspections in GU
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339018079.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.