Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,193,745Inspections Most recent open 2026-08-06 Last loaded 2026-08-10

OSHA Inspection: CERDA INDUSTRIES, INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of CERDA INDUSTRIES, INC. in 7600 SANTA FE DRIVE, HOUSTON, TX 77061 (NAICS 331210). OSHA activity number 339020182.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Cerda Industries, INC. for free Get an email when a new federal OSHA severe-injury report for Cerda Industries, INC. is published. One employer, no account, unsubscribe in one click.
Site address
7600 SANTA FE DRIVE
City
HOUSTON
State
TX
ZIP
77061
Mailing
7600 SANTA FE DRIVE, HOUSTON, TX 77061
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331210
Employees
140
Ownership type
A

5 citations on file for this inspection.

1910.95 C01

Serious Gravity 5 3 instances 50 exposed
Issued
Jul 26, 2013
Abate by
Aug 28, 2013
Penalty
Initial $4,500 · Current $2,700 Reduced
29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.95(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A-scale, or equivalently a dose of fifty percent:   a) In the blast chamber, where an employee's exposure to noise exceeded an 8-hour time-weighted average sound level of 85 decibels measured on the A-scale.      b) In the structural welding department, where an employee's exposure to noise exceeded an 8-hour time-weighted average sound level of 85 decibels measured on the A-scale.    c) In the vessel fabrication department, where an employee's exposure to noise exceeded an 8-hour time-weighted average sound level of 85 decibels measured on the A-scale.
Recent events (2)
  • · I (S) $2700
  • · Z (S) $4500

1910.95 K01

Serious Gravity 1 3 instances 50 exposed
Issued
Jul 26, 2013
Abate by
Aug 28, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.95(k)(1): The employer did not train each employee who is exposed to noise at or above an 8-hour time-weighted average of 85 decibels in accordance with the requirements of 29 CFR 1910.95(k). The employer did not institute a training program and ensure employee participation in the program:   a) In the blast chamber, where an employee who was exposed to noise above an 8-hour time-weighted average of 85 decibels was not trained on the hazards of noise at the time of employment or annually.      b) In the structural welding department, where an employee who was exposed to noise above an 8-hour time-weighted average of 85 decibels was not trained on the hazards of noise at the time of employment or annually.          c) In the vessel fabrication department, where an employee who was exposed to noise levels above an 8-hour time-weighted average of 85 decibels was not trained on the hazards of noise at the time of employment or annually.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.134 I07

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 26, 2013
Abate by
Aug 28, 2013
Penalty
Initial $3,600 · Current $2,160 Reduced
29 CFR 1910.134(i)(7): Oil lubricated compressor(s) used to supply breathing air did not have a high-temperature or carbon monoxide alarm(s) or both:   a)  In the blast area, the oil lubricated, Ingersoll Rand air compressor, HP375, used to supply breathing air to the employee's blast hood, was not equipped with a carbon monoxide meter or high temperature alarm.
Recent events (2)
  • · I (S) $2160
  • · Z (S) $3600

1910.1000 A02

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 26, 2013
Abate by
Dec 11, 2013
Penalty
Initial $4,500 · Current $2,700 Reduced
29 CFR 1910.1000(a)(2): Employee(s) were exposed to an airborne concentration of respirable dust, listed in Table Z-1, in excess of the 8-hour Time Weighted Average concentration of 5 milligrams per cubic meter:   a) In the blast room, where an employee blasting with magnum coal slag abrasives was exposed to respirable dust at levels in excess of 5 milligrams per cubic meter averaged over a period of 8-hours.
Recent events (2)
  • · I (S) $2700
  • · Z (S) $4500

1910.1000 E

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 26, 2013
Abate by
Dec 11, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1000(e): Feasible administrative or engineering controls were not determined and implemented to achieve compliance with the limits prescribed in 29 CFR 1910.1000(a) through (d):  a) In the blast room, where an employee blasting with magnum coal slag abrasives was exposed to respirable dust at levels in excess of 5 milligrams per cubic meter averaged over a period of 8-hours.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

View Cerda Industries, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339020182.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.