OSHA Inspection: STEEL ERECTORS, INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of STEEL ERECTORS, INC in 7400 ABERCORN STREET SUITE 201, SAVANNAH, GA 31406 (NAICS 238120). OSHA activity number 339020406.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Steel Erectors, INC for free Get an email when a new federal OSHA severe-injury report for Steel Erectors, INC is published. One employer, no account, unsubscribe in one click.
Establishment
STEEL ERECTORS, INC
Site address
7400 ABERCORN STREET SUITE 201
City
SAVANNAH
State
GA
ZIP
31406
Mailing
1767 OLD DEAN FOREST ROAD, POOLER, GA 31322
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
45
Ownership type
Private (A)

5 citations on file for this inspection.

1910.212 A03 II

Serious Gravity 10 1 instance 1 exposed
Issued
Jun 18, 2013
Abate by
Jul 15, 2013
Penalty
Initial $4,900 · Current $2,450 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):     a) In the fabrication area, on or about and at times prior to April 25, 2013, the employer did not ensure a cross cut saw that was used by an employee, who worked within twelve inches of the point of operation, to perpendicularly cut steel beam products was adequately guarded, exposing the employer the hazards associated with the amputation of body parts.     ABATEMENT CERTIFICATION AND DOCUMENTATION ARE REQUIRED
Recent events (2)
  • · I (S) $2450
  • · Z (S) $4900

1910.303 B07 I

Serious Gravity 1 1 instance 1 exposed
Issued
Jun 18, 2013
Abate by
Jul 15, 2013
Penalty
Initial $1,785 · Current $893 Reduced
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment:     a) In the welding area of the fabrication building, on or about and at times prior to April 25, 2013, the employer did not ensure a 110 volt electrical breaker box that was used to supply power to the saws was free of missing external knockouts, exposing employees to the hazards associated with burns and smoke inhalation.     ABATEMENT CERTIFICATION IS REQUIRED
Recent events (2)
  • · I (S) $892.5
  • · Z (S) $1785

1910.305 G02 II

Serious Gravity 1 1 instance 1 exposed
Issued
Jun 18, 2013
Abate by
Jul 15, 2013
Penalty
Initial $1,785 · Current $893 Reduced
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap:     a) In the welding area of the fabrication building, on or about and at times prior to April 25, 2013, the employer did not ensure the strain relief of a flexible power cable used to supply power to a welding machine had strain relief that was free of damage, exposing employees to the hazards associated with fire, smoke inhalation, and electrical shock.     ABATEMENT CERTIFICATION IS REQUIRED
Recent events (2)
  • · I (S) $892.5
  • · Z (S) $1785

1910.147 C05 II D

Other-than-serious 1 instance 1 exposed
Issued
Jun 18, 2013
Abate by
Jul 15, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(5)(ii)(D): Lockout devices and tagout devices did not indicate the identity of the employee applying the device(s):   a) In the fabrication building, on or about and at times prior to April 25, 2013, the employer did not ensure that locks used by employees authorized to perform lockout tagout work on equipment with multiple energy sources were marked in such a way to identify the authorized employee.   ABATEMENT CERTIFICATION IS REQUIRED
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.147 C06 II

Other-than-serious 1 instance 1 exposed
Issued
Jun 18, 2013
Abate by
Jul 15, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed:   a) In the fabrication building, on or about and at times prior to April 25, 2013, the employer did not certify, at least annually, the inspections of the lockout tagout procurers for machinery requiring coverage of a lockout tagout program.    ABATEMENT CERTIFICATION IS REQUIRED
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Steel Erectors, INC's full OSHA safety record →