THE VILLAGES, FL —
OSHA Inspection: DIVISION IV, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DIVISION IV, INC. in WORLD OF BEER CORNER OF KIESSEL & MEGGISON ROADS, THE VILLAGES, FL 32163 (NAICS 238140). OSHA activity number 339022261.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DIVISION IV, INC.
- Site address
- WORLD OF BEER CORNER OF KIESSEL & MEGGISON ROADS
- City
- THE VILLAGES
- State
- FL
- ZIP
- 32163
- Mailing
- 8490 NW 43RD LANE, OCALA, FL 34482
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 10
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.451 E01
- Issued
- Jul 17, 2013
- Penalty
- Initial $1,600 · Current $960 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. a) At the jobsite, employees were exposed to fall hazards up to 14 feet while climbing up the end section of the walk through style tubular welded frame scaffolding, in that, an adequate means of access and egress was not provided. Violation observed on or about 4/11/2013.
Recent events (2)
- — I (S) $960
- — Z (S) $1600
1926.451 G01
- Issued
- Jul 17, 2013
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a) At the jobsite, employees in the process of masonry work were exposed to fall hazards up to 20'6" in that, guard rails and midrails were not installed at various locations on tubular welded frame scaffolding, 3 levels high. Violation observed on or about 4/11/2013.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
More inspections at Division IV, INC.
View Division IV, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339022261.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.