OKLAHOMA CITY, OK —
OSHA Inspection: REEL POWER INTERNATIONAL, INC.
Follow-up inspection · Safety discipline
At a glance
On , OSHA opened a follow-up safety inspection of REEL POWER INTERNATIONAL, INC. in 6408 S. EASTERN AVENUE, OKLAHOMA CITY, OK 73149 (NAICS 333298). OSHA activity number 339023202.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- REEL POWER INTERNATIONAL, INC.
- Site address
- 6408 S. EASTERN AVENUE
- City
- OKLAHOMA CITY
- State
- OK
- ZIP
- 73149
- Mailing
- 6408 S. EASTERN AVENUE, OKLAHOMA CITY, OK 73149
What kind of inspection was it?
- Inspection type
- Follow-up (F)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333298
- Employees
- 67
- Ownership type
- A
Citations
10 citations on file for this inspection.
1910.102 A
- Issued
- Oct 23, 2013
- Penalty
- Initial $4,500 · Current $2,700 Reduced
General-duty citation text
29 CFR 1910.102(a): Employers did not ensure that the in-plant transfer, handling, storage, and use of acetylene in cylinders comply with the provisions of CGA Pamphlet G-1-2003 ("Acetylene") (Compressed Gas Association, Inc., 11th ed., 2003). On or about April 24, 2013, the employer did not ensure that compressed gas cylinders in Bay 1 area were stored in accordance with the Compressed Gas Association Pamphlet G-1, section 4.2.5 and section 4.2.10. The employer did not ensure that acetylene cylinders were not stored in close proximity to oxygen cylinders, exposing employees to fire, explosion, and struck-by hazards.
Recent events (2)
- — I (S) $2700
- — Z (S) $4500
1910.178 P01
- Issued
- Oct 23, 2013
- Abate by
- Nov 6, 2013
- Penalty
- Initial $4,500 · Current $2,700 Reduced
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s). On or about April 24, 2013, the employer did not ensure that powered industrials in need of repair were taken out of service until repaired, exposing employees to a struck-by hazard: a. A Hyster H130F powered industrial truck did not have an operable horn. b. A Clark CGC 25 powered industrial truck did not have an operable horn.
Recent events (2)
- — I (S) $2700
- — Z (S) $4500
1910.184 C01
- Issued
- Oct 23, 2013
- Abate by
- Oct 30, 2013
- Penalty
- Initial $3,600 · Current $2,150 Reduced
General-duty citation text
29 CFR 1910.184(c)(1): Slings that were damaged or defective were used. On or about April 24, 2013, and at times prior thereto, the employer did not ensure damaged slings were removed from service, exposing employees to a crushed-by hazard: a. Bay 1 area, Fab 1 section, one nylon sling (EE-2-92) 2 inch sling was being used and was damaged exposing inner fibers. b. Bay 1 area, Fab 2&3 sections, two nylon slings (no identification tags) were being used and were damaged exposing inner fibers. c. Bay 1 area, Fab 8 section, one nylon sling (no identification tag) was being used and was damaged exposing inner fibers. d. Bay 1 area, Fab 5 section, two nylon slings (no identification tag) were being used and were damaged exposing inner fibers. e. Bay 3/ Assembly and Shipping area, one nylon sling (no identification tag) was being used and was damaged exposing inner fibers. f. Machine Shop, one nylon sling (EE-2-92) was being used and was damaged exposing inner fibers.
Recent events (2)
- — I (S) $2150
- — Z (S) $3600
1910.184 D
- Issued
- Oct 23, 2013
- Abate by
- Oct 30, 2013
- Penalty
- Initial $3,600 · Current $0 Reduced
General-duty citation text
29 CFR 1910.184(d): Inspections. Each day before being used, the sling and all fastenings and attachments were not inspected for damage or defects by a competent person designated by the employer. On or about April 24, 2013, and at times prior thereto, the employer did not ensure nylon slings were inspected for damage or defects by a competent person, exposing employees to a crushed-by hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $3600
1910.184 E03 I
- Issued
- Oct 23, 2013
- Abate by
- Oct 30, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.184(e)(3)(i): A thorough periodic inspection of alloy steel chain slings was not made on a regular basis and/or were done at intervals greater than once every 12 months. On or about April 24, 2013, and at times prior thereto, the employer did not ensure an alloy steel chain sling used in Bay 1 was inspected on a regular basis, exposing employees to a crushed-by hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.184 E01
- Issued
- Oct 23, 2013
- Abate by
- Oct 30, 2013
- Penalty
- Initial $3,600 · Current $0 Reduced
General-duty citation text
29 CFR 1910.184(e)(1): Alloy steel chain slings did not have permanently affixed durable identification stating size, grade, rated capacity, and reach. On or about April 24, 2013, and at times prior thereto, the employer did not ensure an alloy steel chain sling being used had a tag identifying the size, grade, rated capacity, and reach, exposing employees to a crushed-by hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $3600
1910.184 I01
- Issued
- Oct 23, 2013
- Abate by
- Oct 30, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.184(i)(1): Each sling was not marked or coded to show the rated capacities for each type of hitch and type of synthetic web material. On or about April 24, 2013, and at times prior thereto, the employer did not ensure each synthetic webbed sling was marked or coded to indicate the rated capacities: a. Bay 1 area, Fab 2&3 sections, two nylon slings with unreadable identification tags were being used. b. Bay 1 area, Fab 8 section, one nylon sling with an unreadable identification tag was being used. c. Bay 1 area, Fab 5 section, two nylon slings with unreadable identification tags were being used. d. Bay 3/ Assembly and Shipping area, one nylon sling with and unreadable identification tag was being used.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Oct 23, 2013
- Abate by
- Oct 24, 2013
- Penalty
- Initial $3,600 · Current $2,150 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. On or about April 24, 2013, the employer did not ensure the points of operation of equipment were guarded: a. An employee was in use of a Kysor Johnson HA-16 horizontal band saw with approximately 11 ½ inches of exposed blade at the point of operation and approximately 4 ½ inches of exposed blade at the right side of the point of operation. The employee was cutting 3 inch wide material exposing the employee to amputation hazards. b. An employee was in use of a Hemsaw side winder auto-4ft with approximately 10 inches of exposed blade at the point of operation and approximately 11 inches of exposed blade at the left side of the point of operation. The employee was cutting two separate 1 inch pieces of material exposing the employee to amputation hazards. c. An employee was in use of a Webb Roller without tripwires provided to shut the roller off in an emergency.
Recent events (2)
- — I (S) $2150
- — Z (S) $3600
1910.242 B
- Issued
- Oct 23, 2013
- Abate by
- Oct 24, 2013
- Penalty
- Initial $3,600 · Current $2,150 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.. On or about April 24, 2013, the employer did not ensure the compressed air gun used for cleaning purposes in Bay 1A was reduced to 30 p.s.i.
Recent events (2)
- — I (S) $2150
- — Z (S) $3600
1910.303 B02
- Issued
- Oct 23, 2013
- Abate by
- Oct 30, 2013
- Penalty
- Initial $3,600 · Current $2,150 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Installation and use. Listed or labeled equipment was not installed and used in accordance with any instructions included in the listing or labeling. On or about April 24, 2013, the employer did not ensure equipment in the Bay 3/assembly area was installed and used according to the instructions included in the listing or label: a. Employees were in use of a 2-outlet receptacle that was not properly installed and fixed into position in accordance with the listing or label. b. Employees were in use of a 4-outlet receptacle that was not properly installed and fixed into position in accordance with the listing or label. c. Employees were in use of a 240 electrical box that was not properly installed and fixed into position in accordance with the listing or label.
Recent events (2)
- — I (S) $2150
- — Z (S) $3600
More inspections at Reel Power International, INC.
View Reel Power International, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 333298)
More inspections in OK
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339023202.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.