Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: REEL POWER INTERNATIONAL, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of REEL POWER INTERNATIONAL, INC. in 6408 S. EASTERN AVENUE, OKLAHOMA CITY, OK 73149 (NAICS 333298). OSHA activity number 340989987.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Reel Power International, INC. — free Get an email when a new federal OSHA severe-injury report for Reel Power International, INC. is published. One employer, no account, unsubscribe in one click.
Site address
6408 S. EASTERN AVENUE
City
OKLAHOMA CITY
State
OK
ZIP
73149
Mailing
6408 S. EASTERN AVENUE, OKLAHOMA CITY, OK 73149
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333298
Employees
60
Ownership type
A

4 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 19, 2015
Abate by
Jan 6, 2016
Penalty
Initial $3,825 · Current $2,295 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    On or about October 14, 2015, and at times prior thereto, in the fabrication department employees were allowed to operate a press brake machine without guards provided in the front and sides of the machine.  Employees were exposed to amputation hazards.
Recent events (2)
  • — I (S) $2295
  • — Z (S) $3825

1910.215 B09

Serious Gravity 1 1 instance 6 exposed
Issued
Nov 19, 2015
Abate by
Nov 30, 2015
Penalty
Initial $2,295 · Current $1,377 Reduced
29 CFR 1910.215(b)(9): Guard for abrasive wheel machine where the operator stands in front of the machine was not constructed so that the peripheral protecting member could be adjusted to the constantly decreasing diameter of the wheel:    On or about October 14, 2015, and at times prior thereto, in the Electrical department the employer allowed employees to operate abrasive wheel grinding machine which did not have tongue guards provided.  Employees were exposed to hazards from flying fragments.
Recent events (2)
  • — I (S) $1377
  • — Z (S) $2295

1910.215 D03

Serious Gravity 1 1 instance 6 exposed
Issued
Nov 19, 2015
Abate by
Nov 30, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.215(d)(3): The contact surface(s) of wheel(s), blotter(s) or flange(s) on grinding machine(s) were not flat and free or foreign matter:    On or about October 14, 2015, and at times prior thereto, in the electrical department area the employer allowed employees to operate abrasive wheel grinding machines that had the wheels worn unevenly.  Employees were exposed to hazards from flying fragments.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B02

Serious Gravity 1 1 instance 7 exposed
Issued
Nov 19, 2015
Abate by
Nov 30, 2015
Penalty
Initial $2,295 · Current $1,377 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    On or about October 14, 2015, and at times prior thereto, electrical equipment were observed being used not in accordance with instructions included in the listing or labeling, including but not limited to the following instances:     1)     In the electrical department, electrical relocatable-power-taps (RPT) were used to provide power to at least four different pieces of electrical equipment and permanently mounted on a structure.     2)     In the electrical and saw department areas, electrical four-plex outlet boxes were used laid on the ground and/or horizontal surfaces instead of mounting on a structure.   Employees were exposed to fire and electrical hazards.
Recent events (2)
  • — I (S) $1377
  • — Z (S) $2295

View Reel Power International, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340989987.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.