Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: WESCO CONSTRUCTION CO.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of WESCO CONSTRUCTION CO. in 100 & 116 W. OXFORD STREET, PHILADELPHIA, PA 19122 (NAICS 238910). OSHA activity number 339027658.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Wesco Construction CO. — free Get an email when a new federal OSHA severe-injury report for Wesco Construction CO. is published. One employer, no account, unsubscribe in one click.
Site address
100 & 116 W. OXFORD STREET
City
PHILADELPHIA
State
PA
ZIP
19122
Mailing
P.O. BOX 99 SAGINAW ROAD, OXFORD, PA 19363
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238910
Employees
12
Ownership type
A

3 citations on file for this inspection.

1910.134 C01

Serious Gravity 1 1 instance 3 exposed
Issued
Sep 26, 2013
Abate by
Nov 30, 2013
Penalty
Initial $1,200 · Current $840 Reduced

Hazardous substances BWPB

29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: (Construction Reference 1926.103):    a) Oxford Mills  - Employees were required to wear half-mask air purifying respirators when they used HEPA vacuums to clean the dust on floors and surfaces in the East and West Buildings.  The employer did not establish and implement a written respiratory protection program as referenced in 1926.103, exposing employees to lead.  Wipe samples of the floor and other surfaces in the East and West Buildings were taken on 4/5/13, 4/8/13, 5/13/13, and 7/10/13 and contained between 317 to 3829 micrograms of lead per 100 square centimeters.      Note:  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $840
  • — Z (S) $1200

1910.134 C02 II

Serious Gravity 1 2 instances 2 exposed
Issued
Sep 26, 2013
Abate by
Nov 30, 2013
Penalty
Initial $0 · Current $0

Hazardous substances BWPB

29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user (Construction Reference 1926.103):     a) Oxford Mills - Employees wore half-mask respirators voluntarily and the employer did not ensure that employees were medically able to wear a respirator, as referenced in 29 CFR 1926.103.  Observed on or about 4/26/13.      b) Oxford Mills - Employees wore half-mask air purifying respirators voluntarily, and the respirators were not cleaned and maintained in a sanitary condition, exposing employees to lead, as referenced in 29 CFR 1926.103.  Wipe samples taken on the inside of respirators worn by two employees contained lead.  Observed on or about 4/26/13.      Note:  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 E01

Serious Gravity 1 1 instance 3 exposed
Issued
Sep 26, 2013
Abate by
Nov 30, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (Construction Reference 1926.103)    a) Oxford Mills  - Employees were required to wear half-mask air purifying respirators when they used HEPA vacuums to clean the dust on floors and surfaces in the East and West Buildings.  The employer did not provide employees with a medical evaluation before requiring them to wear the respirators, exposing employees to potential health hazards.  Observed on or about 7/10/13.       Note:  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Wesco Construction CO.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339027658.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.